A data-based comparison of methods for reducing the peak flow rate in a district heating system

IF 5 Q2 ENERGY & FUELS Smart Energy Pub Date : 2025-02-01 Epub Date: 2024-11-30 DOI:10.1016/j.segy.2024.100168
Felix Agner , Ulrich Trabert , Anders Rantzer , Janybek Orozaliev
{"title":"A data-based comparison of methods for reducing the peak flow rate in a district heating system","authors":"Felix Agner ,&nbsp;Ulrich Trabert ,&nbsp;Anders Rantzer ,&nbsp;Janybek Orozaliev","doi":"10.1016/j.segy.2024.100168","DOIUrl":null,"url":null,"abstract":"<div><div>This work concerns reduction of the peak flow rate of a district heating grid, a key system property which is bounded by pipe dimensions and pumping capacity. The peak flow rate constrains the number of additional consumers that can be connected, and may be a limiting factor in reducing supply temperatures when transitioning to the 4th generation of district heating. We evaluate a full year of operational data from a subset of customer meters in a district heating system in Germany. We consider the peak flow rate reduction that could be achieved with full a posteriori knowledge of this data. Three strategies for reducing the peak flow rate are investigated: A load shifting demand response strategy, an upper limitation in substation return temperatures, and an upper limitation on each substation’s volume flow rate. We show that imposing up to 18 % load flexibility for the customers provides an equal reduction in the peak system flow rate under the load shifting strategy. The limited return temperature strategy is less efficient at curtailing the peak flow rate, but provides an overall reduction of volume flow rates. Finally, the flow rate limitation method can introduce new, higher flow rate peaks, reducing performance.</div></div>","PeriodicalId":34738,"journal":{"name":"Smart Energy","volume":"17 ","pages":"Article 100168"},"PeriodicalIF":5.0000,"publicationDate":"2025-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Smart Energy","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2666955224000388","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/11/30 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"ENERGY & FUELS","Score":null,"Total":0}
引用次数: 0

Abstract

This work concerns reduction of the peak flow rate of a district heating grid, a key system property which is bounded by pipe dimensions and pumping capacity. The peak flow rate constrains the number of additional consumers that can be connected, and may be a limiting factor in reducing supply temperatures when transitioning to the 4th generation of district heating. We evaluate a full year of operational data from a subset of customer meters in a district heating system in Germany. We consider the peak flow rate reduction that could be achieved with full a posteriori knowledge of this data. Three strategies for reducing the peak flow rate are investigated: A load shifting demand response strategy, an upper limitation in substation return temperatures, and an upper limitation on each substation’s volume flow rate. We show that imposing up to 18 % load flexibility for the customers provides an equal reduction in the peak system flow rate under the load shifting strategy. The limited return temperature strategy is less efficient at curtailing the peak flow rate, but provides an overall reduction of volume flow rates. Finally, the flow rate limitation method can introduce new, higher flow rate peaks, reducing performance.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于数据的降低区域供热系统峰值流量方法比较
这项工作涉及降低区域供热网的峰值流量,这是一个受管道尺寸和抽水能力限制的关键系统属性。峰值流量限制了可以连接的额外消费者的数量,并且可能是过渡到第四代区域供热时降低供应温度的限制因素。我们评估了德国区域供热系统中客户仪表子集的全年运行数据。我们考虑峰值流量的降低,可以实现与充分的后验知识的数据。研究了降低峰值流量的三种策略:负荷转移需求响应策略、变电站返回温度上限和每个变电站体积流量上限。我们表明,在负荷转移策略下,为客户施加高达18%的负荷灵活性可提供相等的峰值系统流量降低。限制回流温度策略在降低峰值流量方面效率较低,但总体上降低了体积流量。最后,流量限制方法会引入新的、更高的流量峰值,降低性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Smart Energy
Smart Energy Engineering-Mechanical Engineering
CiteScore
9.20
自引率
0.00%
发文量
29
审稿时长
73 days
期刊最新文献
Decarbonising Italy's energy system with high-resolution thermal demand: Insights from a TRNSYS–H2RES integrated model Addressing climate resilience in energy system modelling: a multi-model framework for Norway Optimal design and performance analysis of photovoltaic power systems for solar vehicles Tuning performance of grey-box models for thermal building applications Near-optimal temperature setpoint transition strategies for peak load reduction and thermal comfort in grid-integrated school buildings
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1