Laser-assisted contact angle measurements.

J F Bush, J W Huff, D L MacKeen
{"title":"Laser-assisted contact angle measurements.","authors":"J F Bush,&nbsp;J W Huff,&nbsp;D L MacKeen","doi":"10.1097/00006324-198809000-00006","DOIUrl":null,"url":null,"abstract":"<p><p>A laser beam, aimed at the solid-liquid-air interface of a sessile drop on a contact lens, produces two lines of diffraction which are theoretically normal to the profile of the fluid and solid surfaces at the point of contact. In the present experiments, the beam and the diffraction patterns were projected on a flat screen perpendicular to the beam, and the angle was measured as a contact angle. The angle was measured on curved surfaces (contact lenses) of 6.5 to 8.9 mm radius and for each material studied, the angle: (1) was independent of the front surface radius, (2) was independent of droplet volume at 2 and 10 microliter, and (3) decreased with time after drop placement. The laser-derived measurements correlated well with contact angles measured by goniometry on contact lenses and a variety of other materials (r = 0.86; p less than 0.0001). Because the diffraction lines are straight and are generated at the point of contact, the angle formed by them is measured easily with a protractor, yielding a convenient and reproducible contact angle measurement. An application of the method was demonstrated by measuring contact angles for saline-containing 0 to 2% bovine serum albumin or bovine submaxillary mucin on Silafocon-A (Polycon II), Pasifocon C (Paragon EW), and polymethyl methacrylate (generic PMMA and Paragon 18) lenses. On each material, physiological concentrations of mucin, but not of albumin, significantly (p greater than 0.01) decreased contact angles by 8 to 15 degrees.(ABSTRACT TRUNCATED AT 250 WORDS)</p>","PeriodicalId":7700,"journal":{"name":"American journal of optometry and physiological optics","volume":"65 9","pages":"722-8"},"PeriodicalIF":0.0000,"publicationDate":"1988-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1097/00006324-198809000-00006","citationCount":"6","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"American journal of optometry and physiological optics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1097/00006324-198809000-00006","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

Abstract

A laser beam, aimed at the solid-liquid-air interface of a sessile drop on a contact lens, produces two lines of diffraction which are theoretically normal to the profile of the fluid and solid surfaces at the point of contact. In the present experiments, the beam and the diffraction patterns were projected on a flat screen perpendicular to the beam, and the angle was measured as a contact angle. The angle was measured on curved surfaces (contact lenses) of 6.5 to 8.9 mm radius and for each material studied, the angle: (1) was independent of the front surface radius, (2) was independent of droplet volume at 2 and 10 microliter, and (3) decreased with time after drop placement. The laser-derived measurements correlated well with contact angles measured by goniometry on contact lenses and a variety of other materials (r = 0.86; p less than 0.0001). Because the diffraction lines are straight and are generated at the point of contact, the angle formed by them is measured easily with a protractor, yielding a convenient and reproducible contact angle measurement. An application of the method was demonstrated by measuring contact angles for saline-containing 0 to 2% bovine serum albumin or bovine submaxillary mucin on Silafocon-A (Polycon II), Pasifocon C (Paragon EW), and polymethyl methacrylate (generic PMMA and Paragon 18) lenses. On each material, physiological concentrations of mucin, but not of albumin, significantly (p greater than 0.01) decreased contact angles by 8 to 15 degrees.(ABSTRACT TRUNCATED AT 250 WORDS)

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
激光辅助接触角测量。
激光束瞄准隐形眼镜上的固体液滴的固体-液体-空气界面,产生两条衍射线,这两条线理论上与接触点的流体和固体表面的轮廓垂直。在本实验中,将光束和衍射图投影在垂直于光束的平面屏幕上,测量角度为接触角。在半径为6.5至8.9 mm的曲面(隐形眼镜)上测量角度,对于所研究的每种材料,角度:(1)与前表面半径无关,(2)与2微升和10微升时的液滴体积无关,(3)随着液滴放置后的时间而减小。激光衍生的测量结果与隐形眼镜和各种其他材料的角测量结果具有良好的相关性(r = 0.86;P < 0.0001)。由于衍射线是直的,并且是在接触点产生的,所以它们形成的角很容易用量角器测量,从而产生方便和可重复的接触角测量。通过在Silafocon-A (Polycon II)、Pasifocon C (Paragon EW)和聚甲基丙烯酸甲酯(通用PMMA和Paragon 18)镜片上测量含盐0 - 2%牛血清白蛋白或牛颌下黏液的接触角,证明了该方法的应用。在每种材料上,生理浓度的粘蛋白显著(p > 0.01)降低接触角8 ~ 15度,而白蛋白不显著(p > 0.01)。(摘要删节250字)
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Age differences in Vistech near contrast sensitivity. Quantitative photorefraction using an off-center flash source. The International Optometric and Optical League. Undercorrection and myopia development. Optometry and science.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1