Mohammadamin Sinichi, Martin J Gevonden, Lydia Krabbendam
{"title":"Quality in Question: Assessing the Accuracy of Four Heart Rate Wearables and the Implications for Psychophysiological Research.","authors":"Mohammadamin Sinichi, Martin J Gevonden, Lydia Krabbendam","doi":"10.1111/psyp.70004","DOIUrl":null,"url":null,"abstract":"<p><p>Heart rate (HR) and heart rate variability (HRV) are two key measures with significant relevance in psychophysiological studies, and their measurement has become more convenient due to advances in wearable technology. However, photoplethysmography (PPG)-based wearables pose critical validity concerns. In this study, we validated four PPG wearables: three consumer-grade devices (Kyto2935, Schone Rhythm 24, and HeartMath Inner Balance Bluetooth) and one research-grade device (Empatica EmbracePlus, successor to the widely-used but discontinued Empatica E4). All devices were worn simultaneously by 40 healthy participants who underwent conditions commonly used in laboratory research (seated rest, arithmetic task, recovery, slow-paced breathing, a neuropsychological task, posture manipulation by standing up) and encountered in ambulatory-like settings (slow walking and stationary biking), compared against a criterion electrocardiography device, the Vrije Universiteit Ambulatory Monitoring System (VU-AMS). We determined the signal quality, the linear strength through regression analysis, the bias through Bland-Altman analysis, and the measurement error through mean arctangent absolute percentage error for each condition against the criterion device. We found that the research-grade device did not outperform the consumer-grade devices in laboratory conditions. It also showed low agreement with the ECG in ambulatory-like conditions. In general, devices captured HR more accurately than HRV. Finally, conditions that deviated from baseline settings and involved slight to high movement, negatively impacted the agreement between PPG devices and the criterion. We conclude that PPG devices, even those advertised and designed for research purposes, may pose validity concerns for HRV measurement in conditions other than those similar to resting states.</p>","PeriodicalId":20913,"journal":{"name":"Psychophysiology","volume":"62 2","pages":"e70004"},"PeriodicalIF":2.9000,"publicationDate":"2025-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11794680/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Psychophysiology","FirstCategoryId":"102","ListUrlMain":"https://doi.org/10.1111/psyp.70004","RegionNum":2,"RegionCategory":"心理学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"NEUROSCIENCES","Score":null,"Total":0}
引用次数: 0
Abstract
Heart rate (HR) and heart rate variability (HRV) are two key measures with significant relevance in psychophysiological studies, and their measurement has become more convenient due to advances in wearable technology. However, photoplethysmography (PPG)-based wearables pose critical validity concerns. In this study, we validated four PPG wearables: three consumer-grade devices (Kyto2935, Schone Rhythm 24, and HeartMath Inner Balance Bluetooth) and one research-grade device (Empatica EmbracePlus, successor to the widely-used but discontinued Empatica E4). All devices were worn simultaneously by 40 healthy participants who underwent conditions commonly used in laboratory research (seated rest, arithmetic task, recovery, slow-paced breathing, a neuropsychological task, posture manipulation by standing up) and encountered in ambulatory-like settings (slow walking and stationary biking), compared against a criterion electrocardiography device, the Vrije Universiteit Ambulatory Monitoring System (VU-AMS). We determined the signal quality, the linear strength through regression analysis, the bias through Bland-Altman analysis, and the measurement error through mean arctangent absolute percentage error for each condition against the criterion device. We found that the research-grade device did not outperform the consumer-grade devices in laboratory conditions. It also showed low agreement with the ECG in ambulatory-like conditions. In general, devices captured HR more accurately than HRV. Finally, conditions that deviated from baseline settings and involved slight to high movement, negatively impacted the agreement between PPG devices and the criterion. We conclude that PPG devices, even those advertised and designed for research purposes, may pose validity concerns for HRV measurement in conditions other than those similar to resting states.
期刊介绍:
Founded in 1964, Psychophysiology is the most established journal in the world specifically dedicated to the dissemination of psychophysiological science. The journal continues to play a key role in advancing human neuroscience in its many forms and methodologies (including central and peripheral measures), covering research on the interrelationships between the physiological and psychological aspects of brain and behavior. Typically, studies published in Psychophysiology include psychological independent variables and noninvasive physiological dependent variables (hemodynamic, optical, and electromagnetic brain imaging and/or peripheral measures such as respiratory sinus arrhythmia, electromyography, pupillography, and many others). The majority of studies published in the journal involve human participants, but work using animal models of such phenomena is occasionally published. Psychophysiology welcomes submissions on new theoretical, empirical, and methodological advances in: cognitive, affective, clinical and social neuroscience, psychopathology and psychiatry, health science and behavioral medicine, and biomedical engineering. The journal publishes theoretical papers, evaluative reviews of literature, empirical papers, and methodological papers, with submissions welcome from scientists in any fields mentioned above.