Cell Culture Media and Raman Spectra Preprocessing Procedures Impact Glucose Chemometrics

IF 2.3 4区 化学 Q1 SOCIAL WORK Journal of Chemometrics Pub Date : 2025-02-05 DOI:10.1002/cem.70005
Naresh Pavurala, Chikkathur N. Madhavarao, Jaeweon Lee, Jayanti Das, Muhammad Ashraf, Thomas O'Connor
{"title":"Cell Culture Media and Raman Spectra Preprocessing Procedures Impact Glucose Chemometrics","authors":"Naresh Pavurala,&nbsp;Chikkathur N. Madhavarao,&nbsp;Jaeweon Lee,&nbsp;Jayanti Das,&nbsp;Muhammad Ashraf,&nbsp;Thomas O'Connor","doi":"10.1002/cem.70005","DOIUrl":null,"url":null,"abstract":"<div>\n \n <p>Deployment of process analytical technology tools such as Raman or IR spectroscopy and associated multivariate calibration models for process monitoring and control plays an important role in process automation and advanced manufacturing of pharmaceuticals. Preprocessing or preparation of the spectroscopic data is an important step in developing a multivariate calibration model. There are several ways available to preprocess the data and each may influence the calibration model performance differently. Here we investigated the influence of preprocessing procedures on the development and performance of the chemometric models to predict the glucose concentration in a bioreactor. Box–Behnken design of experiment (DOE) was used to generate the Raman spectroscopy data. Four factors were considered critical in the DOE—glucose, glutamine, glutamic acid, and antifoam concentration. Raman spectroscopy data were collected both with and without aeration conditions, independently from three cell culture media. For each medium, data consisted of calibration set (27 conditions) and model validation set (9 conditions) separately. Additionally, Raman data was also collected for certain DOE runs with increasing concentration of cell densities ranging from 0.5 × 10 E06/mL to 30 × 10 E06/mL under aerating conditions. Data from the three cell culture media were used separately to develop calibration models that used four different preprocessing procedures, namely, baseline correction (BLC), Savitzky–Golay smoothing (SGS), Savitzky–Golay derivative (SGD) and orthogonal signal correction (OSC). The preprocessing procedures were applied individually and in combinations to evaluate the calibration model parameters and the performance metrics. We further developed glucose calibration models based on partial least squares (PLS) regression with 1–3 principal components. The models developed with OSC procedure gave superior performance metrics with just one principal component across all three media. Models developed with other preprocessing procedures required two or more principal components to give comparable performance. Overall, the choice of preprocessing procedures affected the model performance.</p>\n </div>","PeriodicalId":15274,"journal":{"name":"Journal of Chemometrics","volume":"39 2","pages":""},"PeriodicalIF":2.3000,"publicationDate":"2025-02-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Chemometrics","FirstCategoryId":"92","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/cem.70005","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"SOCIAL WORK","Score":null,"Total":0}
引用次数: 0

Abstract

Deployment of process analytical technology tools such as Raman or IR spectroscopy and associated multivariate calibration models for process monitoring and control plays an important role in process automation and advanced manufacturing of pharmaceuticals. Preprocessing or preparation of the spectroscopic data is an important step in developing a multivariate calibration model. There are several ways available to preprocess the data and each may influence the calibration model performance differently. Here we investigated the influence of preprocessing procedures on the development and performance of the chemometric models to predict the glucose concentration in a bioreactor. Box–Behnken design of experiment (DOE) was used to generate the Raman spectroscopy data. Four factors were considered critical in the DOE—glucose, glutamine, glutamic acid, and antifoam concentration. Raman spectroscopy data were collected both with and without aeration conditions, independently from three cell culture media. For each medium, data consisted of calibration set (27 conditions) and model validation set (9 conditions) separately. Additionally, Raman data was also collected for certain DOE runs with increasing concentration of cell densities ranging from 0.5 × 10 E06/mL to 30 × 10 E06/mL under aerating conditions. Data from the three cell culture media were used separately to develop calibration models that used four different preprocessing procedures, namely, baseline correction (BLC), Savitzky–Golay smoothing (SGS), Savitzky–Golay derivative (SGD) and orthogonal signal correction (OSC). The preprocessing procedures were applied individually and in combinations to evaluate the calibration model parameters and the performance metrics. We further developed glucose calibration models based on partial least squares (PLS) regression with 1–3 principal components. The models developed with OSC procedure gave superior performance metrics with just one principal component across all three media. Models developed with other preprocessing procedures required two or more principal components to give comparable performance. Overall, the choice of preprocessing procedures affected the model performance.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Chemometrics
Journal of Chemometrics 化学-分析化学
CiteScore
5.20
自引率
8.30%
发文量
78
审稿时长
2 months
期刊介绍: The Journal of Chemometrics is devoted to the rapid publication of original scientific papers, reviews and short communications on fundamental and applied aspects of chemometrics. It also provides a forum for the exchange of information on meetings and other news relevant to the growing community of scientists who are interested in chemometrics and its applications. Short, critical review papers are a particularly important feature of the journal, in view of the multidisciplinary readership at which it is aimed.
期刊最新文献
Progress of Complex System Process Analysis Based on Modern Spectroscopy Combined With Chemometrics Comparison of Chemometric Explorative Multi-Omics Data Analysis Methods Applied to a Mechanistic Pan-Cancer Cell Model Improving Vapor Pressure Prediction Through Integration of Multiple Molecular Representations: A Super Learner Approach Nonparametric Threshold Estimation of Autocorrelated Statistics in Multivariate Statistical Process Monitoring Cell Culture Media and Raman Spectra Preprocessing Procedures Impact Glucose Chemometrics
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1