Revitalising high voltage cable: Exploring effective repair methods and influential factors for buffer layer defects using conductive silicone rubber

IF 4.4 2区 工程技术 Q1 ENGINEERING, ELECTRICAL & ELECTRONIC High Voltage Pub Date : 2024-06-19 DOI:10.1049/hve2.12457
Yanyang Yin, Wenqing Zhou, Zhiheng Wu, Jiasheng Huang, Xiaodong Liu, Jian Wang, Gang Liu
{"title":"Revitalising high voltage cable: Exploring effective repair methods and influential factors for buffer layer defects using conductive silicone rubber","authors":"Yanyang Yin,&nbsp;Wenqing Zhou,&nbsp;Zhiheng Wu,&nbsp;Jiasheng Huang,&nbsp;Xiaodong Liu,&nbsp;Jian Wang,&nbsp;Gang Liu","doi":"10.1049/hve2.12457","DOIUrl":null,"url":null,"abstract":"<p>In recent years, the ablative discharge of the buffer layer in high-voltage (HV) cross-linked polyethylene (XLPE) cables has become a significant challenge for the operation and maintenance of power lines. However, there is a lack of effective methods to address buffer layer discharge defects. A practical approach is proposed to repair buffer layer defects and mitigate the associated discharge issues. To achieve this goal, the principles of repairing buffer layer defects are analysed by establishing an electrical network model that considers different contact states between the buffer layer and aluminium sheath. Based on this analysis, a method involving the injection of solidifiable rejuvenation fluid between the buffer layer and aluminium sheath is proposed to effectively suppress buffer layer discharge defects. Through simulation calculations, the minimum electrical conductivity and injection volume required to establish a reliable electrical connection between the buffer layer and aluminium sheath is determined. Additionally, a curable rejuvenation fluid containing conductive carbon black silicone rubber is prepared and analysed for its conductivity and flow properties at both the mesoscopic and macroscopic levels. Finally, a real cable office discharge test is conducted to compare the discharge behaviour of defective cables before and after repair. The results demonstrate that when the conductivity of the rejuvenation fluid exceeds 10<sup>−6</sup> S/m, it effectively establishes a conductive channel between the insulation shield and aluminium sheath, thereby reducing the risk of discharge ablation. Furthermore, after injecting the rejuvenation fluid and completely covering the white mark defect, the discharge phenomenon in the buffer layer is significantly suppressed, leading to the restoration of its electrical performance.</p>","PeriodicalId":48649,"journal":{"name":"High Voltage","volume":"9 6","pages":"1357-1369"},"PeriodicalIF":4.4000,"publicationDate":"2024-06-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1049/hve2.12457","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"High Voltage","FirstCategoryId":"5","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1049/hve2.12457","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

Abstract

In recent years, the ablative discharge of the buffer layer in high-voltage (HV) cross-linked polyethylene (XLPE) cables has become a significant challenge for the operation and maintenance of power lines. However, there is a lack of effective methods to address buffer layer discharge defects. A practical approach is proposed to repair buffer layer defects and mitigate the associated discharge issues. To achieve this goal, the principles of repairing buffer layer defects are analysed by establishing an electrical network model that considers different contact states between the buffer layer and aluminium sheath. Based on this analysis, a method involving the injection of solidifiable rejuvenation fluid between the buffer layer and aluminium sheath is proposed to effectively suppress buffer layer discharge defects. Through simulation calculations, the minimum electrical conductivity and injection volume required to establish a reliable electrical connection between the buffer layer and aluminium sheath is determined. Additionally, a curable rejuvenation fluid containing conductive carbon black silicone rubber is prepared and analysed for its conductivity and flow properties at both the mesoscopic and macroscopic levels. Finally, a real cable office discharge test is conducted to compare the discharge behaviour of defective cables before and after repair. The results demonstrate that when the conductivity of the rejuvenation fluid exceeds 10−6 S/m, it effectively establishes a conductive channel between the insulation shield and aluminium sheath, thereby reducing the risk of discharge ablation. Furthermore, after injecting the rejuvenation fluid and completely covering the white mark defect, the discharge phenomenon in the buffer layer is significantly suppressed, leading to the restoration of its electrical performance.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
High Voltage
High Voltage Energy-Energy Engineering and Power Technology
CiteScore
9.60
自引率
27.30%
发文量
97
审稿时长
21 weeks
期刊介绍: High Voltage aims to attract original research papers and review articles. The scope covers high-voltage power engineering and high voltage applications, including experimental, computational (including simulation and modelling) and theoretical studies, which include: Electrical Insulation ● Outdoor, indoor, solid, liquid and gas insulation ● Transient voltages and overvoltage protection ● Nano-dielectrics and new insulation materials ● Condition monitoring and maintenance Discharge and plasmas, pulsed power ● Electrical discharge, plasma generation and applications ● Interactions of plasma with surfaces ● Pulsed power science and technology High-field effects ● Computation, measurements of Intensive Electromagnetic Field ● Electromagnetic compatibility ● Biomedical effects ● Environmental effects and protection High Voltage Engineering ● Design problems, testing and measuring techniques ● Equipment development and asset management ● Smart Grid, live line working ● AC/DC power electronics ● UHV power transmission Special Issues. Call for papers: Interface Charging Phenomena for Dielectric Materials - https://digital-library.theiet.org/files/HVE_CFP_ICP.pdf Emerging Materials For High Voltage Applications - https://digital-library.theiet.org/files/HVE_CFP_EMHVA.pdf
期刊最新文献
A novel thyristor-based hybrid DC circuit breaker with short arcing capability Fast evaluation on the fatigue level of copper contact wire based on laser induced breakdown spectroscopy and supervised machine learning for high speed railway Discharge image reconstruction and frequency domain analysis based on event data Differences in M-components between triggered lightning striking the ground and overhead line A novel embedded voltage-clamped circuit for multilevel modular converters submodule to suppress very fast transient overvoltage
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1