Age-Dependent Bolus Settings: Insulin-to-Carbohydrate Ratios and Insulin Sensitivity Factors in Pediatric Patients with Type 1 Diabetes on Conventional CSII in the DPV Registry.

IF 5.7 2区 医学 Q1 ENDOCRINOLOGY & METABOLISM Diabetes technology & therapeutics Pub Date : 2025-02-06 DOI:10.1089/dia.2024.0551
Christina Reinauer, Alena Welters, Mareike Niemeyer, Angela Galler, Claudia Boettcher, Lara-Sophie Zehnder, Sabine Kahleyss, Sarah Otto, Reinhard W Holl
{"title":"Age-Dependent Bolus Settings: Insulin-to-Carbohydrate Ratios and Insulin Sensitivity Factors in Pediatric Patients with Type 1 Diabetes on Conventional CSII in the DPV Registry.","authors":"Christina Reinauer, Alena Welters, Mareike Niemeyer, Angela Galler, Claudia Boettcher, Lara-Sophie Zehnder, Sabine Kahleyss, Sarah Otto, Reinhard W Holl","doi":"10.1089/dia.2024.0551","DOIUrl":null,"url":null,"abstract":"<p><p><b><i>Introduction:</i></b> Effective bolus settings for insulin-to-carbohydrate ratios (ICRs) and insulin sensitivity factors (ISFs) are crucial for glycemic control in pediatric patients with type 1 diabetes on insulin pumps. Standard calculation methods based on the total daily insulin dose (TDD) often fall short for children. This study examined insulin pump settings for ICR and ISF in pediatric patients, considering diurnal variation, age, sex, and body mass index (BMI). The goal was to provide data-driven recommendations for initial bolus settings. <b><i>Methods:</i></b> We analyzed insulin pump settings in 7697 pediatric patients with type 1 diabetes in the DPV registry (Diabetes Prospective Follow-up) from Germany, Austria, Switzerland, and Luxembourg. Patients aged 1 to <18 years, postremission (diabetes duration >1 year, insulin dose ≥0.5 IU/kg/d), with good metabolic control (HbA1c ≤7.5%), using insulin pumps with short-acting analog insulin in 2023, were included. Automated insulin delivery system users were excluded. Patients were grouped by age (<6, 6 to <12, 12 to <18 years), BMI percentiles (<P25, P25-75, >P75), and sex. <b><i>Results:</i></b> Older children required more insulin, with lower ICRs and ISFs. Insulin requirements peaked in the morning with the lowest ICR and ISF, with medians (interquartile ranges): <6 years: 11.2 g carbs/IU (9.1-14.0) and 1:150 mg/dL (70-228); 6 to <12 years: 8.7 g carbs/IU (7.0-10.7) and 1:90 (50-140); and 12 to <18 years: 6.1 g carbs/IU (5.0-7.7) and 1:50 (40-80). ISF was highest in the late evening in all age groups, while a higher BMI-SDS was associated with a lower ISF. Girls above 6 years had lower ICR but similar ISF to that of boys. The factor obtained by multiplying ISF and TDD was comparable in all age groups and BMI categories. <b><i>Conclusion:</i></b> Our real-world findings on CSII settings in a large cohort of children with sufficient metabolic control highlight the inadequacy of a single TDD-based calculation formula, as insulin requirements varied by age, time of day, sex, and BMI. These findings may serve as a reference for commonly used age-dependent parameters for clinicians in establishing initial CSII settings before individualized dose titration and optimization.</p>","PeriodicalId":11159,"journal":{"name":"Diabetes technology & therapeutics","volume":" ","pages":""},"PeriodicalIF":5.7000,"publicationDate":"2025-02-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Diabetes technology & therapeutics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1089/dia.2024.0551","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENDOCRINOLOGY & METABOLISM","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: Effective bolus settings for insulin-to-carbohydrate ratios (ICRs) and insulin sensitivity factors (ISFs) are crucial for glycemic control in pediatric patients with type 1 diabetes on insulin pumps. Standard calculation methods based on the total daily insulin dose (TDD) often fall short for children. This study examined insulin pump settings for ICR and ISF in pediatric patients, considering diurnal variation, age, sex, and body mass index (BMI). The goal was to provide data-driven recommendations for initial bolus settings. Methods: We analyzed insulin pump settings in 7697 pediatric patients with type 1 diabetes in the DPV registry (Diabetes Prospective Follow-up) from Germany, Austria, Switzerland, and Luxembourg. Patients aged 1 to <18 years, postremission (diabetes duration >1 year, insulin dose ≥0.5 IU/kg/d), with good metabolic control (HbA1c ≤7.5%), using insulin pumps with short-acting analog insulin in 2023, were included. Automated insulin delivery system users were excluded. Patients were grouped by age (<6, 6 to <12, 12 to <18 years), BMI percentiles (P75), and sex. Results: Older children required more insulin, with lower ICRs and ISFs. Insulin requirements peaked in the morning with the lowest ICR and ISF, with medians (interquartile ranges): <6 years: 11.2 g carbs/IU (9.1-14.0) and 1:150 mg/dL (70-228); 6 to <12 years: 8.7 g carbs/IU (7.0-10.7) and 1:90 (50-140); and 12 to <18 years: 6.1 g carbs/IU (5.0-7.7) and 1:50 (40-80). ISF was highest in the late evening in all age groups, while a higher BMI-SDS was associated with a lower ISF. Girls above 6 years had lower ICR but similar ISF to that of boys. The factor obtained by multiplying ISF and TDD was comparable in all age groups and BMI categories. Conclusion: Our real-world findings on CSII settings in a large cohort of children with sufficient metabolic control highlight the inadequacy of a single TDD-based calculation formula, as insulin requirements varied by age, time of day, sex, and BMI. These findings may serve as a reference for commonly used age-dependent parameters for clinicians in establishing initial CSII settings before individualized dose titration and optimization.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
Diabetes technology & therapeutics
Diabetes technology & therapeutics 医学-内分泌学与代谢
CiteScore
10.60
自引率
14.80%
发文量
145
审稿时长
3-8 weeks
期刊介绍: Diabetes Technology & Therapeutics is the only peer-reviewed journal providing healthcare professionals with information on new devices, drugs, drug delivery systems, and software for managing patients with diabetes. This leading international journal delivers practical information and comprehensive coverage of cutting-edge technologies and therapeutics in the field, and each issue highlights new pharmacological and device developments to optimize patient care.
期刊最新文献
A Cure for Type 1 Diabetes: Are We There Yet? Age-Dependent Bolus Settings: Insulin-to-Carbohydrate Ratios and Insulin Sensitivity Factors in Pediatric Patients with Type 1 Diabetes on Conventional CSII in the DPV Registry. Once-Weekly Insulins. Quantitative Comparison of Glucagon-Like Peptide-1 Receptor Agonists on Weight Loss in Adults: A Systematic Review and Model-Based Meta-Analysis. Safety and Effectiveness of MiniMed™ 780G Advanced Hybrid Closed-Loop Insulin Intensification in Adults with Insulin-Requiring Type 2 Diabetes.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1