Chewing with Co-Cr or PEEK denture frameworks: A randomized crossover clinical study

IF 3.4 2区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE Journal of Prosthodontics-Implant Esthetic and Reconstructive Dentistry Pub Date : 2025-02-07 DOI:10.1111/jopr.14039
Pedro Henrique Bastos de Oliveira DDS, Guilherme Fantini Ferreira DDS, MSc, Lorena Tavares Gama DDS, MSc, Talita Malini Carletti DDS, MSc, PhD, Renata Cunha Matheus Rodrigues Garcia PhD
{"title":"Chewing with Co-Cr or PEEK denture frameworks: A randomized crossover clinical study","authors":"Pedro Henrique Bastos de Oliveira DDS,&nbsp;Guilherme Fantini Ferreira DDS, MSc,&nbsp;Lorena Tavares Gama DDS, MSc,&nbsp;Talita Malini Carletti DDS, MSc, PhD,&nbsp;Renata Cunha Matheus Rodrigues Garcia PhD","doi":"10.1111/jopr.14039","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Purpose</h3>\n \n <p>To compare masticatory function and patient satisfaction with removable partial dentures (RPDs) with cobalt-chromium (Co-Cr) and injected polyetheretherketone (PEEK) frameworks, respectively.</p>\n </section>\n \n <section>\n \n <h3> Materials and Methods</h3>\n \n <p>Twelve volunteers (7 women, 5 men; mean age, 56.6 years) with complete maxillary edentulism and partial mandibular edentulism (Kennedy Class I) first received new RPDs with PEEK (experimental group) or Co-Cr (control group) frameworks and used them for 2 months. Masticatory performance (MP) was evaluated using sieves and Optocal, with results expressed as the mean particle size (<i>X</i><sub>50</sub>); maximum bite force (MBF) was measured with a force transducer and pressure sensors; and self-reported satisfaction was assessed using a visual analog scale. After the initial evaluation, a 1-week washout period was followed by group crossover and reassessment after an additional 2 months. Data were analyzed using independent-samples <i>t-</i>tests (α = 5%).</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p><i>X</i><sub>50</sub> values were lower for RPDs with Co-Cr frameworks than for those with PEEK frameworks (<i>p</i> = 0.007), indicating better MP. The MBF did not differ significantly between RPD framework types. Participants’ satisfaction, in terms of prosthesis stability (<i>p</i> = 0.02) and chewing ability (<i>p</i> &lt; 0.001), was greater for Co-Cr RPDs. Most participants preferred to continue using Co-Cr frameworks.</p>\n </section>\n \n <section>\n \n <h3> Conclusions</h3>\n \n <p>RPDs with injected PEEK frameworks were associated with reduced MP and patient satisfaction relative to Co-Cr frameworks.</p>\n </section>\n </div>","PeriodicalId":49152,"journal":{"name":"Journal of Prosthodontics-Implant Esthetic and Reconstructive Dentistry","volume":"34 7","pages":"686-694"},"PeriodicalIF":3.4000,"publicationDate":"2025-02-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Prosthodontics-Implant Esthetic and Reconstructive Dentistry","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/jopr.14039","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose

To compare masticatory function and patient satisfaction with removable partial dentures (RPDs) with cobalt-chromium (Co-Cr) and injected polyetheretherketone (PEEK) frameworks, respectively.

Materials and Methods

Twelve volunteers (7 women, 5 men; mean age, 56.6 years) with complete maxillary edentulism and partial mandibular edentulism (Kennedy Class I) first received new RPDs with PEEK (experimental group) or Co-Cr (control group) frameworks and used them for 2 months. Masticatory performance (MP) was evaluated using sieves and Optocal, with results expressed as the mean particle size (X50); maximum bite force (MBF) was measured with a force transducer and pressure sensors; and self-reported satisfaction was assessed using a visual analog scale. After the initial evaluation, a 1-week washout period was followed by group crossover and reassessment after an additional 2 months. Data were analyzed using independent-samples t-tests (α = 5%).

Results

X50 values were lower for RPDs with Co-Cr frameworks than for those with PEEK frameworks (p = 0.007), indicating better MP. The MBF did not differ significantly between RPD framework types. Participants’ satisfaction, in terms of prosthesis stability (p = 0.02) and chewing ability (p < 0.001), was greater for Co-Cr RPDs. Most participants preferred to continue using Co-Cr frameworks.

Conclusions

RPDs with injected PEEK frameworks were associated with reduced MP and patient satisfaction relative to Co-Cr frameworks.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用Co-Cr或PEEK义齿框架咀嚼:一项随机交叉临床研究。
目的:比较钴铬(Co-Cr)和注射聚醚醚酮(PEEK)框架可摘局部义齿(RPDs)的咀嚼功能和患者满意度。材料与方法:12名志愿者(女性7名,男性5名;平均年龄56.6岁,患有上颌全牙和部分下颌全牙(Kennedy I类)的患者首先接受新的带有PEEK(实验组)或Co-Cr(对照组)框架的rpd,并使用2个月。咀嚼性能(MP)采用筛分法和Optocal法进行评价,结果用平均粒径(X50)表示;采用力传感器和压力传感器测量最大咬合力(MBF);自我报告的满意度是用视觉模拟量表评估的。初步评估后,进行为期1周的洗脱期,然后在另外2个月后进行组间交叉和重新评估。数据分析采用独立样本t检验(α = 5%)。结果:Co-Cr框架的rpd的X50值低于PEEK框架的rpd (p = 0.007),表明MP更好。MBF在RPD框架类型之间无显著差异。参与者的满意度,在假体稳定性(p = 0.02)和咀嚼能力(p)方面。结论:相对于Co-Cr框架,注射PEEK框架的rpd与MP和患者满意度降低相关。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
7.90
自引率
15.00%
发文量
171
审稿时长
6-12 weeks
期刊介绍: The Journal of Prosthodontics promotes the advanced study and practice of prosthodontics, implant, esthetic, and reconstructive dentistry. It is the official journal of the American College of Prosthodontists, the American Dental Association-recognized voice of the Specialty of Prosthodontics. The journal publishes evidence-based original scientific articles presenting information that is relevant and useful to prosthodontists. Additionally, it publishes reports of innovative techniques, new instructional methodologies, and instructive clinical reports with an interdisciplinary flair. The journal is particularly focused on promoting the study and use of cutting-edge technology and positioning prosthodontists as the early-adopters of new technology in the dental community.
期刊最新文献
Integration of grey relational analysis and deep neural networks for optimized dental shade selection in aesthetic restorations. Spontaneous closure of partial maxillectomy defects using an acrylic removable partial dental prosthesis: A case series. Comparative prosthetic outcomes of two bar attachment systems in mandibular two-implant overdentures: A 5-year pilot study. Artificial intelligence facilitated smile design for the rehabilitation of a fully maxillary edentulous patient with a complete arch implant-supported prosthesis: A dental technique. Straight versus angled screw channel considerations in anterior maxilla using CBCT for planning immediate implant placement: A radiographic study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1