Analysis of Hydrothermal Flow and Performance of Heat Transfer in 3D Pipes Based on Varying Dimple Structure Configurations

IF 2.8 Q2 THERMODYNAMICS Heat Transfer Pub Date : 2024-12-02 DOI:10.1002/htj.23244
Saad Raad Al-Haidari, Ahmed Ramadhan Al-Obaidi
{"title":"Analysis of Hydrothermal Flow and Performance of Heat Transfer in 3D Pipes Based on Varying Dimple Structure Configurations","authors":"Saad Raad Al-Haidari,&nbsp;Ahmed Ramadhan Al-Obaidi","doi":"10.1002/htj.23244","DOIUrl":null,"url":null,"abstract":"<div>\n \n <p>In the current work, the study examines the flow patterns and heat transfer capabilities of tubes with various spherical dimple configurations. A numerical analysis, supported by experimental validation on a reference model, was conducted on a circular tube with an alternating flow path. The primary goal was to enhance the thermal performance of circular tubes by inducing mixing and vortex flows. The impact of three design factors on thermal–hydraulic performance was investigated, dimple pipe diameter (DPD), dimple group number (DGN), and number of dimples (NODs). Dimpled tubes consistently outperformed smooth tubes in heat transfer due to increased flow mixing and separation. Both increasing the Reynolds number and decreasing the design factors led to the formation of mixing and vortex patterns. The performance evaluation factor (PEF) varied across different dimple configurations. For DPD, PEF ranged from 1.14 to 1.33; for DGN, it ranged from 1.15 to 1.28; for NOD, it ranged from 0.95 to 1.21, all within a Reynolds number range of 4000–15,000. At a Reynolds number of 6000, all three configurations of DPD, DGN, and NOD outperformed the smooth pipe in terms of the Nusselt number. For DPD, Nusselt number improvements ranged from 25.7% to 30.8%, and friction factors increased by 21% to 67%. DGN configurations exhibited a wider range of Nusselt number enhancement from 25% to 49.6%, and friction factor increase from 37% to 72%. NOD configurations also demonstrated consistent improvements, with Nusselt number increases ranging from 27.35% to 31% and friction factor increases from 42% to 74%. Spherical dimples can significantly enhance the thermal–hydraulic performance of tubes, so the best configuration depends on the specific application, and the highest performance, with a 1.33 increase in PEF, was achieved with a dimple diameter of 2 mm (DPD = 2 mm) and a dimple density of four dimples per unit area (NOD = 4).</p>\n </div>","PeriodicalId":44939,"journal":{"name":"Heat Transfer","volume":"54 2","pages":"1589-1610"},"PeriodicalIF":2.8000,"publicationDate":"2024-12-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Heat Transfer","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/htj.23244","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"THERMODYNAMICS","Score":null,"Total":0}
引用次数: 0

Abstract

In the current work, the study examines the flow patterns and heat transfer capabilities of tubes with various spherical dimple configurations. A numerical analysis, supported by experimental validation on a reference model, was conducted on a circular tube with an alternating flow path. The primary goal was to enhance the thermal performance of circular tubes by inducing mixing and vortex flows. The impact of three design factors on thermal–hydraulic performance was investigated, dimple pipe diameter (DPD), dimple group number (DGN), and number of dimples (NODs). Dimpled tubes consistently outperformed smooth tubes in heat transfer due to increased flow mixing and separation. Both increasing the Reynolds number and decreasing the design factors led to the formation of mixing and vortex patterns. The performance evaluation factor (PEF) varied across different dimple configurations. For DPD, PEF ranged from 1.14 to 1.33; for DGN, it ranged from 1.15 to 1.28; for NOD, it ranged from 0.95 to 1.21, all within a Reynolds number range of 4000–15,000. At a Reynolds number of 6000, all three configurations of DPD, DGN, and NOD outperformed the smooth pipe in terms of the Nusselt number. For DPD, Nusselt number improvements ranged from 25.7% to 30.8%, and friction factors increased by 21% to 67%. DGN configurations exhibited a wider range of Nusselt number enhancement from 25% to 49.6%, and friction factor increase from 37% to 72%. NOD configurations also demonstrated consistent improvements, with Nusselt number increases ranging from 27.35% to 31% and friction factor increases from 42% to 74%. Spherical dimples can significantly enhance the thermal–hydraulic performance of tubes, so the best configuration depends on the specific application, and the highest performance, with a 1.33 increase in PEF, was achieved with a dimple diameter of 2 mm (DPD = 2 mm) and a dimple density of four dimples per unit area (NOD = 4).

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
Heat Transfer
Heat Transfer THERMODYNAMICS-
CiteScore
6.30
自引率
19.40%
发文量
342
期刊最新文献
Issue Information Numerical Study on the Effect of Trapezoidal-Wave Shaped Partition on Natural Convection Flow Within a Porous Enclosure Investigation of Atomized Droplet Characteristics and Heat Transfer Performance in Minimum Quantity Lubrication Cutting Technology Implementation of a Realistic Multicell CFD Model to Investigate the Thermal Characteristics Within a Solar PV Module Issue Information
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1