Enhancing forensic sex identification through AI-based analysis of the foramen magnum

Sirinart Chomean , Natipong Chatthai , Napakorn Sangchay , Chollanot Kaset
{"title":"Enhancing forensic sex identification through AI-based analysis of the foramen magnum","authors":"Sirinart Chomean ,&nbsp;Natipong Chatthai ,&nbsp;Napakorn Sangchay ,&nbsp;Chollanot Kaset","doi":"10.1016/j.fsir.2025.100411","DOIUrl":null,"url":null,"abstract":"<div><div>Sex estimation from skeletal remains is an essential task in forensic anthropology. Traditional morphological analysis, while effective, can be time-consuming and subject to inter-observer variability. This study evaluates artificial intelligence (AI)-based methods, specifically object detection and instance segmentation, for sex estimation using the foramen magnum (FM). A total of 600 adult dry skull images (300 males, 300 females) were labeled and augmented to create a dataset of 2280 images, which was split into training (92 %), validation (5 %), and test (3 %) sets. The models were trained using Roboflow and assessed based on sensitivity, specificity, accuracy, positive predictive value (PPV), and negative predictive value (NPV), with additional validation performed on 30 independent skulls. The object detection model demonstrated strong performance, achieving high precision (95.0 %) and recall (100.0 %) in training, with precision values of 93.0 % and 89.0 % in validation and test sets, respectively, while maintaining 100.0 % recall across datasets. In the independent test set, the model achieved 75.0 %specificity. The instance segmentation method yielded lower performance, with specificity of 68.75 %. The overall accuracy of the object detection method was 65.68 % (95 % CI: 46.19 % - 81.64 %), outperforming the instance segmentation method, which achieved an accuracy of 62.69 % (95 % CI: 43.22 % - 79.55 %). Although AI-based methods, particularly object detection, show potential for forensic sex estimation from foramen magnum, the results indicate that their accuracy remains lower than traditional morphometric approaches. Future research should focus on integrating additional cranial features and expanding the training dataset to enhance model reliability and generalizability.</div></div>","PeriodicalId":36331,"journal":{"name":"Forensic Science International: Reports","volume":"11 ","pages":"Article 100411"},"PeriodicalIF":0.0000,"publicationDate":"2025-02-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Forensic Science International: Reports","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2665910725000076","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Sex estimation from skeletal remains is an essential task in forensic anthropology. Traditional morphological analysis, while effective, can be time-consuming and subject to inter-observer variability. This study evaluates artificial intelligence (AI)-based methods, specifically object detection and instance segmentation, for sex estimation using the foramen magnum (FM). A total of 600 adult dry skull images (300 males, 300 females) were labeled and augmented to create a dataset of 2280 images, which was split into training (92 %), validation (5 %), and test (3 %) sets. The models were trained using Roboflow and assessed based on sensitivity, specificity, accuracy, positive predictive value (PPV), and negative predictive value (NPV), with additional validation performed on 30 independent skulls. The object detection model demonstrated strong performance, achieving high precision (95.0 %) and recall (100.0 %) in training, with precision values of 93.0 % and 89.0 % in validation and test sets, respectively, while maintaining 100.0 % recall across datasets. In the independent test set, the model achieved 75.0 %specificity. The instance segmentation method yielded lower performance, with specificity of 68.75 %. The overall accuracy of the object detection method was 65.68 % (95 % CI: 46.19 % - 81.64 %), outperforming the instance segmentation method, which achieved an accuracy of 62.69 % (95 % CI: 43.22 % - 79.55 %). Although AI-based methods, particularly object detection, show potential for forensic sex estimation from foramen magnum, the results indicate that their accuracy remains lower than traditional morphometric approaches. Future research should focus on integrating additional cranial features and expanding the training dataset to enhance model reliability and generalizability.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
Forensic Science International: Reports
Forensic Science International: Reports Medicine-Pathology and Forensic Medicine
CiteScore
2.40
自引率
0.00%
发文量
47
审稿时长
57 days
期刊最新文献
Establishing a system of professional self-government of forensic scientists in Ukraine Enhancing forensic sex identification through AI-based analysis of the foramen magnum Firearm fatalities in Dammam: A forensic retrospective study Fatal poisonings in Nordic countries in 2022 among people who use drugs PSA is not suitable as a reliable marker for seminal fluid in rectal samples collected post-mortem
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1