Three-year changes in ocular biometric components in children with amblyopia.

IF 1.7 4区 医学 Q3 OPHTHALMOLOGY BMC Ophthalmology Pub Date : 2025-02-10 DOI:10.1186/s12886-025-03895-2
Masoud Khorrami-Nejad, Roqayeh Aliyari, Ali Nouraeinejad, Mohsen Heirani, Mohammad Hassan Emamian, Hassan Hashemi, Akbar Fotouhi
{"title":"Three-year changes in ocular biometric components in children with amblyopia.","authors":"Masoud Khorrami-Nejad, Roqayeh Aliyari, Ali Nouraeinejad, Mohsen Heirani, Mohammad Hassan Emamian, Hassan Hashemi, Akbar Fotouhi","doi":"10.1186/s12886-025-03895-2","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Amblyopia is associated with structural differences in ocular biometrics, but existing studies often lack long-term follow-ups. This study compares three-year changes in ocular biometric components in amblyopic and non-amblyopic eyes.</p><p><strong>Methods: </strong>In this prospective cohort, study data were collected in 2015 and 2018 in Shahroud, northeast Iran. The sample comprised 4968 primary students (9935 eyes), including 4931 non-amblyopic students (9893 eyes) and 37 students with amblyopia (42 eyes). Axial length, keratometry, central corneal thickness, lens thickness, pupil diameter, anterior chamber depth, lens power and vitreous chamber depth were measured using Lenstar LS900. Multilevel mixed-effects regression models were used to determine any association between variables.</p><p><strong>Results: </strong>The mean age of children without and with amblyopia at baseline were 9.7 ± 1.7 and 9.9 ± 1.5 years, respectively. The mean axial elongation in amblyopic and non-amblyopic groups over three years was 0.37 (95% CI: 0.34-0.40) and 0.33 mm (95% CI: 0.31-0.34), respectively (p < 0.001). Amblyopic eyes showed greater axial elongation than non-amblyopic eyes (p < 0.001). Anterior chamber depth was constant in amblyopic eyes while it decreased in non-amblyopic eyes by 0.13 mm. Vitreous chamber depth increased significantly in both groups, with a greater increase observed in the amblyopic eyes (0.36 vs. 0.28 mm) (p < 0.001). Flat and steep keratometry increased significantly in amblyopic eyes (p < 0.001), while it was constant in non-amblyopic eyes. Lens power decreased significantly in both groups (p < 0.001). The increase in the axial length and vitreous chamber depth in the amblyopic eye was greater than in the non-amblyopic eyes (p < 0.001). The spherical equivalent change in both groups was - 0.31 D.</p><p><strong>Conclusions: </strong>Amblyopia was associated with significant changes in key biometric parameters, offering valuable insight into the structural alterations underlying the condition.</p>","PeriodicalId":9058,"journal":{"name":"BMC Ophthalmology","volume":"25 1","pages":"68"},"PeriodicalIF":1.7000,"publicationDate":"2025-02-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11809108/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMC Ophthalmology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s12886-025-03895-2","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Amblyopia is associated with structural differences in ocular biometrics, but existing studies often lack long-term follow-ups. This study compares three-year changes in ocular biometric components in amblyopic and non-amblyopic eyes.

Methods: In this prospective cohort, study data were collected in 2015 and 2018 in Shahroud, northeast Iran. The sample comprised 4968 primary students (9935 eyes), including 4931 non-amblyopic students (9893 eyes) and 37 students with amblyopia (42 eyes). Axial length, keratometry, central corneal thickness, lens thickness, pupil diameter, anterior chamber depth, lens power and vitreous chamber depth were measured using Lenstar LS900. Multilevel mixed-effects regression models were used to determine any association between variables.

Results: The mean age of children without and with amblyopia at baseline were 9.7 ± 1.7 and 9.9 ± 1.5 years, respectively. The mean axial elongation in amblyopic and non-amblyopic groups over three years was 0.37 (95% CI: 0.34-0.40) and 0.33 mm (95% CI: 0.31-0.34), respectively (p < 0.001). Amblyopic eyes showed greater axial elongation than non-amblyopic eyes (p < 0.001). Anterior chamber depth was constant in amblyopic eyes while it decreased in non-amblyopic eyes by 0.13 mm. Vitreous chamber depth increased significantly in both groups, with a greater increase observed in the amblyopic eyes (0.36 vs. 0.28 mm) (p < 0.001). Flat and steep keratometry increased significantly in amblyopic eyes (p < 0.001), while it was constant in non-amblyopic eyes. Lens power decreased significantly in both groups (p < 0.001). The increase in the axial length and vitreous chamber depth in the amblyopic eye was greater than in the non-amblyopic eyes (p < 0.001). The spherical equivalent change in both groups was - 0.31 D.

Conclusions: Amblyopia was associated with significant changes in key biometric parameters, offering valuable insight into the structural alterations underlying the condition.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
BMC Ophthalmology
BMC Ophthalmology OPHTHALMOLOGY-
CiteScore
3.40
自引率
5.00%
发文量
441
审稿时长
6-12 weeks
期刊介绍: BMC Ophthalmology is an open access, peer-reviewed journal that considers articles on all aspects of the prevention, diagnosis and management of eye disorders, as well as related molecular genetics, pathophysiology, and epidemiology.
期刊最新文献
Effect of factors on the space between the posterior capsule and IOL. Comparative evaluation of phacoemulsification combined with goniosynechi-alysis with goniotomy versus trabeculectomy in patients with angle-closure glaucoma and cataract. Correlation of contrast sensitivity at low spatial frequencies with myopic shift in Chinese children. Management of fracture and displacement of a previously successful bilateral transconjunctival ab-externo XEN gel stent: a case report. Diurnal variations in corneal biomechanics in healthy young adults.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1