Wearable Electrocardiogram Technology: Help or Hindrance to the Modern Doctor?

Q2 Medicine JMIR Cardio Pub Date : 2025-02-10 DOI:10.2196/62719
Samuel Smith, Shalisa Maisrikrod
{"title":"Wearable Electrocardiogram Technology: Help or Hindrance to the Modern Doctor?","authors":"Samuel Smith, Shalisa Maisrikrod","doi":"10.2196/62719","DOIUrl":null,"url":null,"abstract":"<p><strong>Unlabelled: </strong>Electrocardiography is an essential tool in the arsenal of medical professionals, Traditionally, patients have been required to meet health care practitioners in person to have an electrocardiogram (ECG) recorded and interpreted. This may result in paroxysmal arrhythmias being missed, as well as decreased patient convenience, and thus reduced uptake. The advent of wearable ECG devices built into consumer smartwatches has allowed unparalleled access to ECG monitoring for patients. Not only are these modern devices more portable than traditional Holter monitors, but with the addition of artificial intelligence (AI)-led rhythm interpretation, diagnostic accuracy is improved greatly when compared with conventional ECG-machine interpretation. The improved wearability may also translate into increased rates of detected arrhythmias. Despite the many positives, wearable ECG technology brings with it its own challenges. Diagnostic accuracy, managing patient expectations and limitations, and incorporating home ECG monitoring into clinical guidelines have all arisen as challenges for the modern clinician. Decentralized monitoring and patient alerts to supposed arrhythmias have the potential to increase patient anxiety and health care visitations (and therefore costs). To better obtain meaningful data from these devices, provide optimal patient care, and provide meaningful explanations to patients, providers need to understand the basic sciences underpinning these devices, how these relate to the surface ECG, and the implications in diagnostic accuracy. This review article examines the underlying physiological principles of electrocardiography, as well as examines how wearable ECGs have changed the clinical landscape today, where their limitations lie, and what clinicians can expect in the future with their increasing use.</p>","PeriodicalId":14706,"journal":{"name":"JMIR Cardio","volume":"9 ","pages":"e62719"},"PeriodicalIF":0.0000,"publicationDate":"2025-02-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11833192/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"JMIR Cardio","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2196/62719","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Unlabelled: Electrocardiography is an essential tool in the arsenal of medical professionals, Traditionally, patients have been required to meet health care practitioners in person to have an electrocardiogram (ECG) recorded and interpreted. This may result in paroxysmal arrhythmias being missed, as well as decreased patient convenience, and thus reduced uptake. The advent of wearable ECG devices built into consumer smartwatches has allowed unparalleled access to ECG monitoring for patients. Not only are these modern devices more portable than traditional Holter monitors, but with the addition of artificial intelligence (AI)-led rhythm interpretation, diagnostic accuracy is improved greatly when compared with conventional ECG-machine interpretation. The improved wearability may also translate into increased rates of detected arrhythmias. Despite the many positives, wearable ECG technology brings with it its own challenges. Diagnostic accuracy, managing patient expectations and limitations, and incorporating home ECG monitoring into clinical guidelines have all arisen as challenges for the modern clinician. Decentralized monitoring and patient alerts to supposed arrhythmias have the potential to increase patient anxiety and health care visitations (and therefore costs). To better obtain meaningful data from these devices, provide optimal patient care, and provide meaningful explanations to patients, providers need to understand the basic sciences underpinning these devices, how these relate to the surface ECG, and the implications in diagnostic accuracy. This review article examines the underlying physiological principles of electrocardiography, as well as examines how wearable ECGs have changed the clinical landscape today, where their limitations lie, and what clinicians can expect in the future with their increasing use.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
JMIR Cardio
JMIR Cardio Computer Science-Computer Science Applications
CiteScore
3.50
自引率
0.00%
发文量
25
审稿时长
12 weeks
期刊最新文献
Optimization of the Care4Today Digital Health Platform to Enhance Self-Reporting of Medication Adherence and Health Experiences in Patients With Coronary or Peripheral Artery Disease: Mixed Methods Study. Exploring Stakeholder Perspectives on the Barriers and Facilitators of Implementing Digital Technologies for Heart Disease Diagnosis: Qualitative Study. Predicting Atrial Fibrillation Relapse Using Bayesian Networks: Explainable AI Approach. Wearable Electrocardiogram Technology: Help or Hindrance to the Modern Doctor? Technology Readiness Level and Self-Reported Health in Recipients of an Implantable Cardioverter Defibrillator: Cross-Sectional Study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1