Impact of Postoperative Walking vs. Lying Down on IOL Rotation After Lens Surgery: A Prospective Comparative Study.

IF 3.2 3区 医学 Q2 OPHTHALMOLOGY Journal of cataract and refractive surgery Pub Date : 2025-02-11 DOI:10.1097/j.jcrs.0000000000001632
Tyll Jandewerth, Klemens Paul Kaiser, Eva Hemkeppler, Christoph Lwowski, Thomas Kohnen
{"title":"Impact of Postoperative Walking vs. Lying Down on IOL Rotation After Lens Surgery: A Prospective Comparative Study.","authors":"Tyll Jandewerth, Klemens Paul Kaiser, Eva Hemkeppler, Christoph Lwowski, Thomas Kohnen","doi":"10.1097/j.jcrs.0000000000001632","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To determine the intraocular lens (IOL) rotational stability depending on patient position in the first postoperative hour after femtosecond laser assisted cataract or refractive surgery with implantation of a non-toric IOL in the capsular bag.</p><p><strong>Setting: </strong>Department of Ophthalmology, Goethe-University, Frankfurt, Germany.</p><p><strong>Design: </strong>Prospective, randomized clinical trial.</p><p><strong>Methods: </strong>In this study, 38 eyes of 36 patients received femtosecond laser assisted phacoemulsification and implantation of a non-toric IOL in the capsular bag. Patients were randomized into two groups: patients laid down for one hour after surgery due to the clinical standard (LD group), patients walked around in the first postoperative hour (W group). No miotic eye drops were applied at the end of operation. A retroilluminated slit lamp picture was taken at the end of the operation (baseline), one hour and one day postoperative. Changes in IOL position were measured by an axis between two episcleral landmarks and the haptics of the IOL. Measurements were performed by an image processing application specified for medical and scientific purpose. If not normally distributed, the paired t-test was used. Otherwise, the Mann-Whitney-U-Test was used if data was not normally distributed.</p><p><strong>Results: </strong>IOL rotation in the first hour was 1.80° ± 1.80° in the LD group and 1.21° ± 2.11° in the W group (p=0.123). One day after operation, IOL position differed from the baseline measurement with 1.52° ± 1.89° in the LD group and 1.51° ± 1.69° in the W group (p=0.773).</p><p><strong>Conclusion: </strong>Early postoperative patient position does not seem to influence IOL rotational stability.</p>","PeriodicalId":15214,"journal":{"name":"Journal of cataract and refractive surgery","volume":" ","pages":""},"PeriodicalIF":3.2000,"publicationDate":"2025-02-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of cataract and refractive surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/j.jcrs.0000000000001632","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To determine the intraocular lens (IOL) rotational stability depending on patient position in the first postoperative hour after femtosecond laser assisted cataract or refractive surgery with implantation of a non-toric IOL in the capsular bag.

Setting: Department of Ophthalmology, Goethe-University, Frankfurt, Germany.

Design: Prospective, randomized clinical trial.

Methods: In this study, 38 eyes of 36 patients received femtosecond laser assisted phacoemulsification and implantation of a non-toric IOL in the capsular bag. Patients were randomized into two groups: patients laid down for one hour after surgery due to the clinical standard (LD group), patients walked around in the first postoperative hour (W group). No miotic eye drops were applied at the end of operation. A retroilluminated slit lamp picture was taken at the end of the operation (baseline), one hour and one day postoperative. Changes in IOL position were measured by an axis between two episcleral landmarks and the haptics of the IOL. Measurements were performed by an image processing application specified for medical and scientific purpose. If not normally distributed, the paired t-test was used. Otherwise, the Mann-Whitney-U-Test was used if data was not normally distributed.

Results: IOL rotation in the first hour was 1.80° ± 1.80° in the LD group and 1.21° ± 2.11° in the W group (p=0.123). One day after operation, IOL position differed from the baseline measurement with 1.52° ± 1.89° in the LD group and 1.51° ± 1.69° in the W group (p=0.773).

Conclusion: Early postoperative patient position does not seem to influence IOL rotational stability.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
人工晶状体术后行走与平躺对人工晶状体旋转的影响:一项前瞻性比较研究。
目的:探讨飞秒激光辅助白内障或屈光手术后囊袋内非环形人工晶状体植入术后1小时内不同体位的人工晶状体旋转稳定性。单位:德国法兰克福歌德大学眼科。设计:前瞻性、随机临床试验。方法:对36例38眼患者行飞秒激光辅助超声乳化术及囊袋内非环形人工晶状体植入术。患者随机分为两组:术后1小时按临床标准卧床1小时(LD组),术后1小时走动1小时(W组)。手术结束时不使用微滴眼液。手术结束(基线)、术后1小时和1天逆光裂隙灯拍照。IOL位置的变化是通过两个外膜标志之间的轴和IOL的触觉来测量的。测量是由医学和科学目的指定的图像处理应用程序执行的。如果不是正态分布,则使用配对t检验。否则,如果数据不是正态分布,则使用Mann-Whitney-U-Test。结果:LD组人工晶状体旋转1 h为1.80°±1.80°,W组为1.21°±2.11°(p=0.123)。术后1 d, LD组人工晶状体位置与基线测量值差异为1.52°±1.89°,W组为1.51°±1.69°(p=0.773)。结论:术后早期患者体位不影响人工晶状体旋转稳定性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
5.60
自引率
14.30%
发文量
259
审稿时长
8.5 weeks
期刊介绍: The Journal of Cataract & Refractive Surgery (JCRS), a preeminent peer-reviewed monthly ophthalmology publication, is the official journal of the American Society of Cataract and Refractive Surgery (ASCRS) and the European Society of Cataract and Refractive Surgeons (ESCRS). JCRS publishes high quality articles on all aspects of anterior segment surgery. In addition to original clinical studies, the journal features a consultation section, practical techniques, important cases, and reviews as well as basic science articles.
期刊最新文献
Optimization of crystalline lens refractive index to improve the accuracy of intraocular lens power calculation in patients with dense cataract. Cataract Extraction with Capsular Bag Scleral Fixation in a Patient with a Congenital Lens Coloboma. Reply to "Re: "Efficacy of intracameral moxifloxacin in prevention of post cataract surgery endophthalmitis: randomized control trial". Comment On: Efficacy of intracameral moxifloxacin in prevention of postcataract surgery endophthalmitis: randomized control trial. Generative Artificial Intelligence for Postoperative Parameters Prediction in Implantable Collamer Lens Surgery.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1