Comparison of fibreoptic-guided tracheal intubation through LMA Protector and i-gel in adult paralysed patients - A randomised comparative study.

IF 1.9 Q1 ANESTHESIOLOGY Indian Journal of Anaesthesia Pub Date : 2024-12-01 Epub Date: 2024-12-03 DOI:10.4103/ija.ija_656_24
Mamta Bhardwaj, Karthik Manoharan, Kirti Kshetrapal, Karishma Dhankhar, Amit Singh, Susheela Taxak
{"title":"Comparison of fibreoptic-guided tracheal intubation through LMA Protector and i-gel in adult paralysed patients - A randomised comparative study.","authors":"Mamta Bhardwaj, Karthik Manoharan, Kirti Kshetrapal, Karishma Dhankhar, Amit Singh, Susheela Taxak","doi":"10.4103/ija.ija_656_24","DOIUrl":null,"url":null,"abstract":"<p><strong>Background and aims: </strong>Second-generation supraglottic airway devices (SADs) are used for ventilation and a conduit for fibreoptic-guided tracheal intubation (FGI). LMA Protector is a novel second-generation SAD with a wide airway lumen to pass an adequately sized tracheal tube. Few authors have compared LMA Protector with i-gel for FGI using reinforced tubes, and their results have been contradictory. Polyvinyl chloride (PVC) endotracheal tube (ETT) is the most commonly used ETT in the operation theatre and critical care units. Hence, we conducted this study to compare FGI through i-gel and LMA Protector using PVC ETT.</p><p><strong>Methods: </strong>After institutional committee approval and trial registration, 66 patients aged 18-70 years with American Society of Anesthesiologists physical status I/II were recruited for this randomised study. Patients were randomly allocated to groups LP and IG. The primary outcome was to compare time to tracheal intubation via two SADs. Insertion characteristics such as the number of insertion attempts, mean time of insertion, oropharyngeal leak pressure, and intubation characteristics (time to view carina, number of attempts, etc.) were considered secondary outcomes. Independent Student's <i>t</i>-test and Mann-Whitney U test were applied for normally distributed and non-normally distributed quantitative variables, respectively.</p><p><strong>Results: </strong>Demographic parameters were comparable in the two groups (<i>P</i> > 0.05). The time to view the carina, tracheal intubation time, other insertion characteristics, and adverse effects were comparable between the groups (<i>P</i> > 0.05).</p><p><strong>Conclusion: </strong>LMA Protector and i-gel are technically comparable conduits for fibreoptic-guided tracheal intubation in adult paralysed patients.</p>","PeriodicalId":13339,"journal":{"name":"Indian Journal of Anaesthesia","volume":"68 12","pages":"1049-1054"},"PeriodicalIF":1.9000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11812508/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Indian Journal of Anaesthesia","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/ija.ija_656_24","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/12/3 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"ANESTHESIOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background and aims: Second-generation supraglottic airway devices (SADs) are used for ventilation and a conduit for fibreoptic-guided tracheal intubation (FGI). LMA Protector is a novel second-generation SAD with a wide airway lumen to pass an adequately sized tracheal tube. Few authors have compared LMA Protector with i-gel for FGI using reinforced tubes, and their results have been contradictory. Polyvinyl chloride (PVC) endotracheal tube (ETT) is the most commonly used ETT in the operation theatre and critical care units. Hence, we conducted this study to compare FGI through i-gel and LMA Protector using PVC ETT.

Methods: After institutional committee approval and trial registration, 66 patients aged 18-70 years with American Society of Anesthesiologists physical status I/II were recruited for this randomised study. Patients were randomly allocated to groups LP and IG. The primary outcome was to compare time to tracheal intubation via two SADs. Insertion characteristics such as the number of insertion attempts, mean time of insertion, oropharyngeal leak pressure, and intubation characteristics (time to view carina, number of attempts, etc.) were considered secondary outcomes. Independent Student's t-test and Mann-Whitney U test were applied for normally distributed and non-normally distributed quantitative variables, respectively.

Results: Demographic parameters were comparable in the two groups (P > 0.05). The time to view the carina, tracheal intubation time, other insertion characteristics, and adverse effects were comparable between the groups (P > 0.05).

Conclusion: LMA Protector and i-gel are technically comparable conduits for fibreoptic-guided tracheal intubation in adult paralysed patients.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
通过LMA保护器和i-gel在成人瘫痪患者中纤维引导气管插管的比较-一项随机对照研究。
背景和目的:第二代声门上气道装置(SADs)用于通气和纤维引导气管插管(FGI)的导管。LMA保护器是一种新型的第二代SAD,具有宽气道管腔以通过适当大小的气管管。很少有作者将LMA保护剂与i-gel用于增强管的FGI进行比较,其结果相互矛盾。聚氯乙烯(PVC)气管内管是手术室和重症监护病房最常用的气管内管。因此,我们进行了这项研究,比较了通过i-gel和使用PVC ETT的LMA保护器的FGI。方法:经机构委员会批准和试验注册后,66例年龄18-70岁,美国麻醉医师学会身体状态为I/II的患者被纳入本随机研究。患者随机分为LP组和IG组。主要结果是比较通过两个SADs进行气管插管的时间。插入特征,如插入次数、平均插入时间、口咽漏压和插管特征(观察隆突的时间、尝试次数等)被认为是次要结局。正态分布和非正态分布的定量变量分别采用独立学生t检验和Mann-Whitney U检验。结果:两组患者人口学参数具有可比性(P < 0.05)。两组间观察隆突时间、气管插管时间、其他插入特征及不良反应具有可比性(P < 0.05)。结论:LMA保护器和i-gel在成人瘫痪患者的纤维引导气管插管中具有技术可比性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
4.20
自引率
44.80%
发文量
210
审稿时长
36 weeks
期刊最新文献
Ulnar sparing/Lower trunk sparing: A more accurate descriptor than ulnar nerve sparing in supraclavicular blocks. Mid-part of adductor canal: Is it the optimal injection site for performing adductor canal block? A cadaver-based injection study. Efficacy of rhomboid intercostal block for postoperative analgesia in patients undergoing breast surgery: A systematic review and meta-analysis. Comparison of local anaesthetic versus saline erector spinae plane block for perioperative opioid consumption and postoperative pain in open posterior spine surgeries - A randomised controlled trial. Decoding quadratus lumborum blocks: Fascial pathways and analgesic coverage-A narrative review.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1