Three-unit CAD/CAM-manufactured lithium disilicate FDPs after an average observation period of 120 months

IF 5.5 2区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE Journal of dentistry Pub Date : 2025-04-01 Epub Date: 2025-02-11 DOI:10.1016/j.jdent.2025.105625
Martin Homa , Oliver Schneider , Peter Neumann , Lutz Endres , Nicole Rafai , Sven Reich , Stefan Wolfart , Taskin Tuna
{"title":"Three-unit CAD/CAM-manufactured lithium disilicate FDPs after an average observation period of 120 months","authors":"Martin Homa ,&nbsp;Oliver Schneider ,&nbsp;Peter Neumann ,&nbsp;Lutz Endres ,&nbsp;Nicole Rafai ,&nbsp;Sven Reich ,&nbsp;Stefan Wolfart ,&nbsp;Taskin Tuna","doi":"10.1016/j.jdent.2025.105625","DOIUrl":null,"url":null,"abstract":"<div><h3>Objective</h3><div>In recent decades, CAD/CAM-fabricated lithium disilicate restorations have become popular and have been approved for fixed dental protheses (FDPs) up to the second premolar since 2013. This multicenter follow-up study collected long-term clinical data on three-unit anterior and premolar FDPs made of lithium disilicate to evaluate the material's suitability over &gt;10 years.</div></div><div><h3>Methods</h3><div>Thirty-two patients received a total of 32 three-unit anterior or premolar monolithic lithium disilicate FDPs. In exceptional aesthetically demanding cases, the labial cut back technique was used for minimal additional veneering. The study was conducted at University Hospital Aachen and three external private dental practices. Failure was defined as any event leading to the loss of an FDP. The survival and success rates were calculated using the Kaplan-Meier method. At the last follow-up examination in 2023 and 2024, 17 of the 32 patients (53,1 %) were re-examined.</div></div><div><h3>Results</h3><div>The average observation period was 10 years and the longest follow-up period was 15 years. The cumulative survival rate after 10 years was 84.4 %. In detail the five failures recorded were due to one fracture of the connector, one repeated loss of retention, two cases of persistent pain and one loss of an abutment tooth. The cumulative success rate was 75 %.</div></div><div><h3>Conclusion</h3><div>Within the limitations of this study, lithium disilicate for CAD/CAM manufacturing appears to be a reliable material for full-contour three-unit FDPs, provided that the most posterior abutment tooth does not extend beyond the second premolar and that minimum connector thicknesses are maintained. In aesthetically demanding cases, the labial cut back technique combined with additional veneering can be used.</div></div><div><h3>Clinical significance</h3><div>This study is one of the few to provide long-term data on the clinical performance of three-unit FDPs made from lithium disilicate, specifically examining cases with premolar abutments. The findings highlight the reliability of this material under the specified conditions.</div></div>","PeriodicalId":15585,"journal":{"name":"Journal of dentistry","volume":"155 ","pages":"Article 105625"},"PeriodicalIF":5.5000,"publicationDate":"2025-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of dentistry","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0300571225000703","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/2/11 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Objective

In recent decades, CAD/CAM-fabricated lithium disilicate restorations have become popular and have been approved for fixed dental protheses (FDPs) up to the second premolar since 2013. This multicenter follow-up study collected long-term clinical data on three-unit anterior and premolar FDPs made of lithium disilicate to evaluate the material's suitability over >10 years.

Methods

Thirty-two patients received a total of 32 three-unit anterior or premolar monolithic lithium disilicate FDPs. In exceptional aesthetically demanding cases, the labial cut back technique was used for minimal additional veneering. The study was conducted at University Hospital Aachen and three external private dental practices. Failure was defined as any event leading to the loss of an FDP. The survival and success rates were calculated using the Kaplan-Meier method. At the last follow-up examination in 2023 and 2024, 17 of the 32 patients (53,1 %) were re-examined.

Results

The average observation period was 10 years and the longest follow-up period was 15 years. The cumulative survival rate after 10 years was 84.4 %. In detail the five failures recorded were due to one fracture of the connector, one repeated loss of retention, two cases of persistent pain and one loss of an abutment tooth. The cumulative success rate was 75 %.

Conclusion

Within the limitations of this study, lithium disilicate for CAD/CAM manufacturing appears to be a reliable material for full-contour three-unit FDPs, provided that the most posterior abutment tooth does not extend beyond the second premolar and that minimum connector thicknesses are maintained. In aesthetically demanding cases, the labial cut back technique combined with additional veneering can be used.

Clinical significance

This study is one of the few to provide long-term data on the clinical performance of three-unit FDPs made from lithium disilicate, specifically examining cases with premolar abutments. The findings highlight the reliability of this material under the specified conditions.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
三单元CAD/ cam制造的二硅酸锂fdp平均观察期为120个月。
目的:近几十年来,CAD/ cam制造的二硅酸锂修复体越来越受欢迎,自2013年以来已被批准用于第二前磨牙的固定牙体(fdp)。这项多中心随访研究收集了由二硅酸锂制成的三单元前磨牙和前磨牙fdp的长期临床数据,以评估该材料在10多年中的适用性。方法:32例患者共接受32颗三单元前牙或前臼齿整体式二硅酸锂FDPs。在特殊的审美要求的情况下,唇切回技术用于最小的额外贴面。这项研究是在亚琛大学医院和三家外部私人牙科诊所进行的。失败被定义为任何导致FDP丢失的事件。生存率和成功率采用Kaplan-Meier法计算。在2023年和2024年的最后一次随访检查中,32例患者中有17例(53.1%)再次检查。结果:平均观察时间为10年,最长随访时间为15年。10年后的累计生存率为84.4%。详细记录的5例失败是由于1例连接器断裂,1例反复丢失固位,2例持续疼痛和1例基牙丢失。累计成功率为75%。结论:在本研究的限制范围内,用于CAD/CAM制造的二硅酸锂似乎是全轮廓三单元fdp的可靠材料,前提是最后的基牙不超过第二前磨牙,并且保持最小的连接器厚度。在审美要求苛刻的情况下,唇切回技术结合额外的贴面可以使用。临床意义:本研究是为数不多的提供由二硅酸锂制成的三单元fdp临床性能长期数据的研究之一,特别是对有前磨牙基牙的病例进行了研究。研究结果强调了这种材料在特定条件下的可靠性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of dentistry
Journal of dentistry 医学-牙科与口腔外科
CiteScore
7.30
自引率
11.40%
发文量
349
审稿时长
35 days
期刊介绍: The Journal of Dentistry has an open access mirror journal The Journal of Dentistry: X, sharing the same aims and scope, editorial team, submission system and rigorous peer review. The Journal of Dentistry is the leading international dental journal within the field of Restorative Dentistry. Placing an emphasis on publishing novel and high-quality research papers, the Journal aims to influence the practice of dentistry at clinician, research, industry and policy-maker level on an international basis. Topics covered include the management of dental disease, periodontology, endodontology, operative dentistry, fixed and removable prosthodontics, dental biomaterials science, long-term clinical trials including epidemiology and oral health, technology transfer of new scientific instrumentation or procedures, as well as clinically relevant oral biology and translational research. The Journal of Dentistry will publish original scientific research papers including short communications. It is also interested in publishing review articles and leaders in themed areas which will be linked to new scientific research. Conference proceedings are also welcome and expressions of interest should be communicated to the Editor.
期刊最新文献
Repair vs replacement of defective composite restorations: Teaching in dental schools in Indonesia Trueness of artificial intelligence-driven CBCT tooth segmentation: A comparative validation ex vivo pilot study Wear, fracture strength, and reliability of three-unit definitive fixed dental prostheses fabricated with different vat polymerization methods An automated framework for quantitative alveolar bone loss using deep learning-based landmark detection The relative accuracy of dynamic navigation-guided and conventional coronectomy for mandibular third molars: A randomized controlled trial
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1