Investigating the relationship between subacromial balloon spacer study outcomes and study funding

IF 2.9 2区 医学 Q1 ORTHOPEDICS Journal of Shoulder and Elbow Surgery Pub Date : 2025-10-01 Epub Date: 2025-02-13 DOI:10.1016/j.jse.2024.12.052
Cailan L. Feingold BS , Eric H. Lin BA , Ajith K. Subhash MD , Joshua M. Yazditabar MS , Avinesh Agarwalla MD , Joseph N. Liu MD
{"title":"Investigating the relationship between subacromial balloon spacer study outcomes and study funding","authors":"Cailan L. Feingold BS ,&nbsp;Eric H. Lin BA ,&nbsp;Ajith K. Subhash MD ,&nbsp;Joshua M. Yazditabar MS ,&nbsp;Avinesh Agarwalla MD ,&nbsp;Joseph N. Liu MD","doi":"10.1016/j.jse.2024.12.052","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><div>Subacromial balloon spacers are implants used for the treatment of irreparable rotator cuff tears. Many studies on subacromial balloon spacers use industry funding and existing literature has shown that industry funding can impact reported outcomes in research. This study aims to evaluate the outcomes of industry-funded balloon spacer studies. We hypothesized that industry-funded studies are more likely to report positive results than studies without funding.</div></div><div><h3>Methods</h3><div>PubMed, Scopus, and Embase were searched using the term “balloon spacer” from January 1, 2000 to the present. Inclusion criteria were (1) a study on subacromial balloon spacers with (2) funding or conflict of interest explicitly documented. Outcomes of studies were categorized into “positive” if the null hypothesis was rejected or the outcomes favored the implant, “neutral” if the null hypothesis was confirmed, or “negative” if the result did not favor the implant. Funding type was grouped by “no funding” or “industry funding”, studies with other funding types such as specialty society or National Institutes of Health. Agreement between 2 reviewers in categorization of study outcome was analyzed using Cohen's kappa. Statistical analyses were conducted using Fisher’s exact tests. The level of significance was set at α = 0.05 with a Bonferroni correction of <em>P</em> &lt; .0125.</div></div><div><h3>Results</h3><div>Twenty studies were included for analysis: 9 (45%) were industry-funded, 8 (40%) received no funding, and 3 (15%) received other funding. Of the 9 industry-funded studies, 8 (88.9%) reported “positive” outcomes and 1 (11.1%) reported a “neutral” outcome. Of the 8 nonfunded studies, 4 (50%) reported “positive” outcomes, 2 (25%) reported “negative” outcomes, and 2 (25%) reported “neutral” outcomes. For studies with other funding, 1 (33.3%) was “positive”, 1 (33.3%) was “negative”, and 1 (33.3%) was “neutral.” Cohen's kappa of 0.806 indicated substantial agreement. By Fisher’s exact test, industry-funded studies were significantly more likely to report “positive” outcomes than nonfunded studies (<em>P</em> = .0105) but not more than studies with other funding (<em>P</em> = .6000).</div></div><div><h3>Conclusion</h3><div>Industry funding in studies on subacromial balloon spacers significantly increases the chance of the study reporting a “positive” outcome compared with nonfunded studies. Clinicians using published literature to direct the use of subacromial balloon spacers in their practice should be wary of how study funding might impact their reported outcomes.</div></div>","PeriodicalId":50051,"journal":{"name":"Journal of Shoulder and Elbow Surgery","volume":"34 10","pages":"Pages e944-e953"},"PeriodicalIF":2.9000,"publicationDate":"2025-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Shoulder and Elbow Surgery","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1058274625001430","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/2/13 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

Background

Subacromial balloon spacers are implants used for the treatment of irreparable rotator cuff tears. Many studies on subacromial balloon spacers use industry funding and existing literature has shown that industry funding can impact reported outcomes in research. This study aims to evaluate the outcomes of industry-funded balloon spacer studies. We hypothesized that industry-funded studies are more likely to report positive results than studies without funding.

Methods

PubMed, Scopus, and Embase were searched using the term “balloon spacer” from January 1, 2000 to the present. Inclusion criteria were (1) a study on subacromial balloon spacers with (2) funding or conflict of interest explicitly documented. Outcomes of studies were categorized into “positive” if the null hypothesis was rejected or the outcomes favored the implant, “neutral” if the null hypothesis was confirmed, or “negative” if the result did not favor the implant. Funding type was grouped by “no funding” or “industry funding”, studies with other funding types such as specialty society or National Institutes of Health. Agreement between 2 reviewers in categorization of study outcome was analyzed using Cohen's kappa. Statistical analyses were conducted using Fisher’s exact tests. The level of significance was set at α = 0.05 with a Bonferroni correction of P < .0125.

Results

Twenty studies were included for analysis: 9 (45%) were industry-funded, 8 (40%) received no funding, and 3 (15%) received other funding. Of the 9 industry-funded studies, 8 (88.9%) reported “positive” outcomes and 1 (11.1%) reported a “neutral” outcome. Of the 8 nonfunded studies, 4 (50%) reported “positive” outcomes, 2 (25%) reported “negative” outcomes, and 2 (25%) reported “neutral” outcomes. For studies with other funding, 1 (33.3%) was “positive”, 1 (33.3%) was “negative”, and 1 (33.3%) was “neutral.” Cohen's kappa of 0.806 indicated substantial agreement. By Fisher’s exact test, industry-funded studies were significantly more likely to report “positive” outcomes than nonfunded studies (P = .0105) but not more than studies with other funding (P = .6000).

Conclusion

Industry funding in studies on subacromial balloon spacers significantly increases the chance of the study reporting a “positive” outcome compared with nonfunded studies. Clinicians using published literature to direct the use of subacromial balloon spacers in their practice should be wary of how study funding might impact their reported outcomes.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
探讨肩峰下球囊间隔器研究结果与研究经费的关系。
简介:肩峰下球囊垫片是用于治疗不可修复的肩袖撕裂的植入物。许多关于肩峰下气球间隔器的研究使用了行业资助,现有文献表明,行业资助可以影响研究报告的结果。本研究旨在评估工业界资助的气球间隔研究的结果。我们假设,行业资助的研究比没有资助的研究更有可能报告积极的结果。方法:检索2000年1月1日至今的PubMed、Scopus和Embase数据库。纳入标准为:(1)肩峰下球囊垫片研究,(2)资金或利益冲突(COI)明确记录。如果零假设被拒绝或结果有利于植入物,研究结果被分类为“积极”,如果零假设被证实,则为“中性”,如果结果不利于植入物,则为“消极”。资助类型按“无资助”或“行业资助”分组,有专业协会或国家卫生研究所等其他资助类型的研究。采用Cohen’s kappa分析两位评论者对研究结果分类的一致性。采用Fisher精确检验进行统计分析。显著性水平设为α = 0.05, Bonferroni校正p < 0.0125。结果:纳入20项研究进行分析;9个(45%)由工业界资助,8个(40%)没有得到资助,3个(15%)得到其他资助。在9项行业资助的研究中,8项(88.9%)报告了“积极”结果,1项(11.1%)报告了“中性”结果。在8项未获资助的研究中,4项(50%)报告了“积极”结果,2项(25%)报告了“消极”结果,2项(25%)报告了“中性”结果。对于其他资助的研究,1(33.3%)为“阳性”,1(33.3%)为“阴性”,1(33.3%)为“中性”。Cohen的kappa值为0.806,表明双方的观点基本一致。通过Fisher精确检验,工业界资助的研究报告“积极”结果的可能性明显高于非资助的研究(p=0.0105),但不高于其他资助的研究(p=0.6000)。结论:与非资助研究相比,工业资助的肩峰下球囊垫片研究显著增加了研究报告“积极”结果的机会。临床医生在实践中使用已发表的文献来指导肩峰下气囊垫片的使用,应警惕研究资金可能会如何影响其报告的结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
6.50
自引率
23.30%
发文量
604
审稿时长
11.2 weeks
期刊介绍: The official publication for eight leading specialty organizations, this authoritative journal is the only publication to focus exclusively on medical, surgical, and physical techniques for treating injury/disease of the upper extremity, including the shoulder girdle, arm, and elbow. Clinically oriented and peer-reviewed, the Journal provides an international forum for the exchange of information on new techniques, instruments, and materials. Journal of Shoulder and Elbow Surgery features vivid photos, professional illustrations, and explicit diagrams that demonstrate surgical approaches and depict implant devices. Topics covered include fractures, dislocations, diseases and injuries of the rotator cuff, imaging techniques, arthritis, arthroscopy, arthroplasty, and rehabilitation.
期刊最新文献
Muscle activation variability in relation to functional internal rotation in reverse total shoulder arthroplasty Measurement properties of patient-reported outcome measures for rotator cuff repair surgery Functional and radiographic outcomes after surgical management of complex proximal ulna fractures: a retrospective case series Pyrolytic carbon head hemiarthroplasty vs. cobalt-chromium head for proximal humerus fractures: a short-term follow-up study Incidence and risk factors for aseptic glenoid baseplate loosening in primary reverse shoulder arthroplasty using the Aramis implant baseplate with a minimum of 2 years follow-up
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1