Impact of a novel limbal-rigid contact lens on potential cost savings in Stevens-Johnson syndrome patients from postmarket surveillance

AJO International Pub Date : 2025-04-28 Epub Date: 2025-01-22 DOI:10.1016/j.ajoint.2025.100101
Kenichi Kimura , Mayumi Ueta , Hideki Fukuoka , Koji Kitazawa , Tsutomu Inatomi , Shigeru Kinoshita , Ryoichi Shiota , Naoki Yamauchi , Jiro Miyazaki , Satomi Sakabayashi , Satoshi Teramukai , Kojiro Imai , Kenji Konomi , Yuichi Uchino , Yoko Ogawa , Takefumi Yamaguchi , Jun Shimazaki , Yoshiyuki Satake , Chie Sotozono
{"title":"Impact of a novel limbal-rigid contact lens on potential cost savings in Stevens-Johnson syndrome patients from postmarket surveillance","authors":"Kenichi Kimura ,&nbsp;Mayumi Ueta ,&nbsp;Hideki Fukuoka ,&nbsp;Koji Kitazawa ,&nbsp;Tsutomu Inatomi ,&nbsp;Shigeru Kinoshita ,&nbsp;Ryoichi Shiota ,&nbsp;Naoki Yamauchi ,&nbsp;Jiro Miyazaki ,&nbsp;Satomi Sakabayashi ,&nbsp;Satoshi Teramukai ,&nbsp;Kojiro Imai ,&nbsp;Kenji Konomi ,&nbsp;Yuichi Uchino ,&nbsp;Yoko Ogawa ,&nbsp;Takefumi Yamaguchi ,&nbsp;Jun Shimazaki ,&nbsp;Yoshiyuki Satake ,&nbsp;Chie Sotozono","doi":"10.1016/j.ajoint.2025.100101","DOIUrl":null,"url":null,"abstract":"<div><h3>Purpose</h3><div>To investigate the safety, efficacy, and potential-cost-savings of a newly-developed limbal-rigid contact lens (CL) via postmarket surveillance (PMS).</div></div><div><h3>Design</h3><div>Postmarket prospective observational use-results surveillance with cost-savings analysis.</div></div><div><h3>Methods</h3><div>We examined 80 eyes of 68 Stevens-Johnson syndrome (SJS) cases using the newly-developed Suncon Kyoto-CS limbal-rigid CL (Sun Contact Lens). CL-wear-associated best-corrected visual acuity (BCVA), objective signs (i.e., bulbar-conjunctival hyperemia, upper-eyelid conjunctival scarring, eye discharge, keratoconjunctival epithelial defect, corneal opacification, and corneal neovascularization), and subjective symptoms (i.e., dryness and eye pain) at baseline and at 6-months of CL use were measured and compared, with adverse events noted. Potential cost savings from improvements in CL-wear-related BCVA were estimated based on the potential for improvements in each patient's visual-impairment-grade under the Japanese Pharmaceuticals and Medical Devices Agency (PMDA) disability pension plan. Main outcome measures were potential cost savings via use of the CL. Secondary outcome measures were CL safety and efficacy via PMS.</div></div><div><h3>Results</h3><div>At 6-months of CL use, the median BCVA in the CL-fitted eyes improved from 1.30 to 0.70 logMAR compared to that of spectacle correction at baseline (<em>P</em> &lt; 0.001), and improvement of bulbar-conjunctival hyperemia, dryness, and eye pain was observed (<em>P</em> &lt; 0.001, <em>P</em> &lt; 0.001, and <em>P</em> &lt; 0.001, respectively). No serious adverse events occurred. Potential-cost-savings analysis showed visual-impairment-grade improvement in 18 (28.6 %) of 63 patients. Considering the financial amount of the PMDA disability pension, estimated total potential cost savings was &gt;6.9-million U.S. dollars.</div></div><div><h3>Conclusion</h3><div>The newly-developed limbal-rigid CL was found safe and effective for treating SJS-associated ocular sequelae, and potentially reduces disability-pension costs.</div></div>","PeriodicalId":100071,"journal":{"name":"AJO International","volume":"2 1","pages":"Article 100101"},"PeriodicalIF":0.0000,"publicationDate":"2025-04-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"AJO International","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2950253525000048","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/22 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose

To investigate the safety, efficacy, and potential-cost-savings of a newly-developed limbal-rigid contact lens (CL) via postmarket surveillance (PMS).

Design

Postmarket prospective observational use-results surveillance with cost-savings analysis.

Methods

We examined 80 eyes of 68 Stevens-Johnson syndrome (SJS) cases using the newly-developed Suncon Kyoto-CS limbal-rigid CL (Sun Contact Lens). CL-wear-associated best-corrected visual acuity (BCVA), objective signs (i.e., bulbar-conjunctival hyperemia, upper-eyelid conjunctival scarring, eye discharge, keratoconjunctival epithelial defect, corneal opacification, and corneal neovascularization), and subjective symptoms (i.e., dryness and eye pain) at baseline and at 6-months of CL use were measured and compared, with adverse events noted. Potential cost savings from improvements in CL-wear-related BCVA were estimated based on the potential for improvements in each patient's visual-impairment-grade under the Japanese Pharmaceuticals and Medical Devices Agency (PMDA) disability pension plan. Main outcome measures were potential cost savings via use of the CL. Secondary outcome measures were CL safety and efficacy via PMS.

Results

At 6-months of CL use, the median BCVA in the CL-fitted eyes improved from 1.30 to 0.70 logMAR compared to that of spectacle correction at baseline (P < 0.001), and improvement of bulbar-conjunctival hyperemia, dryness, and eye pain was observed (P < 0.001, P < 0.001, and P < 0.001, respectively). No serious adverse events occurred. Potential-cost-savings analysis showed visual-impairment-grade improvement in 18 (28.6 %) of 63 patients. Considering the financial amount of the PMDA disability pension, estimated total potential cost savings was >6.9-million U.S. dollars.

Conclusion

The newly-developed limbal-rigid CL was found safe and effective for treating SJS-associated ocular sequelae, and potentially reduces disability-pension costs.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
从上市后监测来看,一种新型角膜缘硬性隐形眼镜对Stevens-Johnson综合征患者潜在成本节约的影响
目的通过上市后监测(PMS)研究新研制的角膜缘硬性隐形眼镜(CL)的安全性、有效性和潜在的成本节约。设计上市后前瞻性观察性使用结果监测与成本节约分析。方法对68例Stevens-Johnson综合征(SJS)患者的80只眼进行检查,采用新研制的Suncon Kyoto-CS角膜缘刚性太阳隐形眼镜(Sun Contact Lens)。在基线和使用CL 6个月时测量并比较CL配戴相关最佳矫正视力(BCVA)、客观体征(即球结膜充血、上睑结膜瘢痕、眼排出物、角膜结膜上皮缺损、角膜混浊和角膜新生血管)和主观症状(即干燥和眼痛),并记录不良事件。根据日本药品和医疗器械管理局(PMDA)残疾养老金计划,根据每位患者视力受损等级的改善潜力,估计了cl佩戴相关BCVA改善的潜在成本节约。主要结果测量是通过使用CL节省的潜在成本。次要结局指标是经PMS检测的CL安全性和有效性。结果使用CL 6个月后,与基线矫正时相比,CL配戴眼的中位BCVA从1.30 logMAR提高到0.70 logMAR (P <;0.001),观察到球结膜充血、干燥和眼痛的改善(P <;0.001, P <;0.001, P <;分别为0.001)。未发生严重不良事件。潜在成本节约分析显示,63例患者中有18例(28.6%)的视力受损等级得到改善。考虑到PMDA残疾养恤金的财务金额,估计潜在的总成本节省为690万美元。结论新研制的角膜缘刚性巩膜移植治疗sjs相关眼部后遗症安全有效,可降低残疾抚恤金费用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Intensive phacoemulsification training in Rwanda: Surgical outcomes of a structured training programme Feasibility and safety of an AI-driven postoperative telephone system for cataract surgery follow-up in Canada Identifying rapid glaucoma progressors at baseline using 10–2 visual field testing Intravitreal methotrexate after retinal detachment repair: A Canadian retrospective cohort study of feasibility and safety Anterior segment findings from community outreach screening in Timor-Leste using the smart eye camera: A pilot telemedicine feasibility study
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1