Chromatographic Separation and Trace Level Quantification of Ten Nitrosamine Genotoxic Impurities in a Single Chromatography Technique through Atmospheric Pressure Chemical Ionization (APCI) Coupled with Triple Quardrapole Analyser in Telmisartan Drug Products

IF 1.2 4区 化学 Q4 BIOCHEMICAL RESEARCH METHODS Chromatographia Pub Date : 2025-01-27 DOI:10.1007/s10337-025-04387-7
Mehul Pathak, Dhara D. Patel, Dalip Kumar
{"title":"Chromatographic Separation and Trace Level Quantification of Ten Nitrosamine Genotoxic Impurities in a Single Chromatography Technique through Atmospheric Pressure Chemical Ionization (APCI) Coupled with Triple Quardrapole Analyser in Telmisartan Drug Products","authors":"Mehul Pathak,&nbsp;Dhara D. Patel,&nbsp;Dalip Kumar","doi":"10.1007/s10337-025-04387-7","DOIUrl":null,"url":null,"abstract":"<div><p>The detection and quantification of genotoxic impurities, specifically nitrosamines, in pharmaceuticals have garnered high regulatory attention due to their potential carcinogenic effects. This study presents a comprehensive validation of a liquid chromatography with Atmospheric Pressure Chemical Ionization (APCI) Coupled with Triple Quardrapole Analyser (LC-MS/MS) method tailored for the determination of multiple nitrosamine impurities including N-nitrosodimethylamine (NDMA), N-nitroso methyl butyl amine (NMBA), N-nitrosodiethylamine (NDEA), N-nitroso diethyl isopropyl amine (NEIPA), N-nitrosodiisopropylamine (NDIPA), N-nitroso methyl ethyl amine (NMPA), N-nitroso propyl amine (NDPA), N-nitrosopiperidine (NPIP), N-nitrosopyrrolidine (NPYR), and N-nitroso butyl amine (NDBA) in telmisartan tablet formulations. The method was meticulously validated according to the International Council for Harmonisation (ICH) guidelines, focusing on critical parameters such as specificity, accuracy, precision, limit of detection (LOD), limit of quantification (LOQ), and filter compatibility. The specificity of the method was rigorously established, demonstrating unequivocal differentiation between nitrosamine impurities and potential interferences from excipients and active pharmaceutical ingredients (APIs). Recovery studies validated the method’s accuracy, yielding recoveries within the acceptable range of 70–120% across various concentration levels, confirming its reliability for routine analysis. Precision was assessed through the relative standard deviation (RSD) of multiple replicate analyses, with RSD values consistently below the ICH threshold of &lt; 15%, underscoring the method’s reproducibility. Sensitivity assessments revealed exceptional LODs as low as 10.76 ppb and LOQs around 33.00 ppb for several nitrosamines, significantly exceeding current regulatory limits for genotoxic impurities. Evaluations of filter compatibility indicated that both 0.22 µm PVDF and 0.2 µm nylon filters are effective for sample preparation, ensuring the integrity of the analytes during the filtration process. Upon application of the validated method to commercial 40 mg telmisartan tablets, all targeted nitrosamines were undetected, affirming the method’s applicability in routine quality control settings. This work culminates in the establishment of a highly sensitive, specific, and robust LC–MS/MS methodology for the detection of nitrosamine impurities in telmisartan, addressing regulatory concerns while ensuring patient safety. The low detection thresholds provided by this method position it as an invaluable tool for pharmaceutical manufacturers and regulatory bodies, facilitating stringent monitoring and compliance with safety standards, ultimately enhancing the safety profile of medicinal products in the market.</p></div>","PeriodicalId":518,"journal":{"name":"Chromatographia","volume":"88 2","pages":"169 - 177"},"PeriodicalIF":1.2000,"publicationDate":"2025-01-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Chromatographia","FirstCategoryId":"92","ListUrlMain":"https://link.springer.com/article/10.1007/s10337-025-04387-7","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

Abstract

The detection and quantification of genotoxic impurities, specifically nitrosamines, in pharmaceuticals have garnered high regulatory attention due to their potential carcinogenic effects. This study presents a comprehensive validation of a liquid chromatography with Atmospheric Pressure Chemical Ionization (APCI) Coupled with Triple Quardrapole Analyser (LC-MS/MS) method tailored for the determination of multiple nitrosamine impurities including N-nitrosodimethylamine (NDMA), N-nitroso methyl butyl amine (NMBA), N-nitrosodiethylamine (NDEA), N-nitroso diethyl isopropyl amine (NEIPA), N-nitrosodiisopropylamine (NDIPA), N-nitroso methyl ethyl amine (NMPA), N-nitroso propyl amine (NDPA), N-nitrosopiperidine (NPIP), N-nitrosopyrrolidine (NPYR), and N-nitroso butyl amine (NDBA) in telmisartan tablet formulations. The method was meticulously validated according to the International Council for Harmonisation (ICH) guidelines, focusing on critical parameters such as specificity, accuracy, precision, limit of detection (LOD), limit of quantification (LOQ), and filter compatibility. The specificity of the method was rigorously established, demonstrating unequivocal differentiation between nitrosamine impurities and potential interferences from excipients and active pharmaceutical ingredients (APIs). Recovery studies validated the method’s accuracy, yielding recoveries within the acceptable range of 70–120% across various concentration levels, confirming its reliability for routine analysis. Precision was assessed through the relative standard deviation (RSD) of multiple replicate analyses, with RSD values consistently below the ICH threshold of < 15%, underscoring the method’s reproducibility. Sensitivity assessments revealed exceptional LODs as low as 10.76 ppb and LOQs around 33.00 ppb for several nitrosamines, significantly exceeding current regulatory limits for genotoxic impurities. Evaluations of filter compatibility indicated that both 0.22 µm PVDF and 0.2 µm nylon filters are effective for sample preparation, ensuring the integrity of the analytes during the filtration process. Upon application of the validated method to commercial 40 mg telmisartan tablets, all targeted nitrosamines were undetected, affirming the method’s applicability in routine quality control settings. This work culminates in the establishment of a highly sensitive, specific, and robust LC–MS/MS methodology for the detection of nitrosamine impurities in telmisartan, addressing regulatory concerns while ensuring patient safety. The low detection thresholds provided by this method position it as an invaluable tool for pharmaceutical manufacturers and regulatory bodies, facilitating stringent monitoring and compliance with safety standards, ultimately enhancing the safety profile of medicinal products in the market.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
Chromatographia
Chromatographia 化学-分析化学
CiteScore
3.40
自引率
5.90%
发文量
103
审稿时长
2.2 months
期刊介绍: Separation sciences, in all their various forms such as chromatography, field-flow fractionation, and electrophoresis, provide some of the most powerful techniques in analytical chemistry and are applied within a number of important application areas, including archaeology, biotechnology, clinical, environmental, food, medical, petroleum, pharmaceutical, polymer and biopolymer research. Beyond serving analytical purposes, separation techniques are also used for preparative and process-scale applications. The scope and power of separation sciences is significantly extended by combination with spectroscopic detection methods (e.g., laser-based approaches, nuclear-magnetic resonance, Raman, chemiluminescence) and particularly, mass spectrometry, to create hyphenated techniques. In addition to exciting new developments in chromatography, such as ultra high-pressure systems, multidimensional separations, and high-temperature approaches, there have also been great advances in hybrid methods combining chromatography and electro-based separations, especially on the micro- and nanoscale. Integrated biological procedures (e.g., enzymatic, immunological, receptor-based assays) can also be part of the overall analytical process.
期刊最新文献
Thank You to Our Reviewers in 2024 Chromatographic Separation and Trace Level Quantification of Ten Nitrosamine Genotoxic Impurities in a Single Chromatography Technique through Atmospheric Pressure Chemical Ionization (APCI) Coupled with Triple Quardrapole Analyser in Telmisartan Drug Products Development and Validation of Confirmatory Quantitative and Screening Methods for 63 Prohibited Substances in Horse Urine Using LC–MS/MS Effect of Short-Chain Organic Acids, Cations and Anions on the Retention of Citicoline Under Hydrophilic Interaction Liquid Chromatography Conditions Eco-friendly Statistical Chemometric-Assisted Spectrophotometric and Chromatographic Model Development in Hydrotropic Solutions for Commercial Drug Formulations
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1