Effect of Core Structure on the Mechanical and Electromagnetic Properties of High-Temperature Superconducting Cables

IF 2 3区 工程技术 Q3 MATERIALS SCIENCE, MULTIDISCIPLINARY Acta Mechanica Solida Sinica Pub Date : 2024-10-07 DOI:10.1007/s10338-024-00527-y
Jiangtao Yan, Yuanwen Gao
{"title":"Effect of Core Structure on the Mechanical and Electromagnetic Properties of High-Temperature Superconducting Cables","authors":"Jiangtao Yan,&nbsp;Yuanwen Gao","doi":"10.1007/s10338-024-00527-y","DOIUrl":null,"url":null,"abstract":"<div><p>Research on the mechanical–electrical properties is crucial for designing and preparing high-temperature superconducting (HTS) cables. Various winding core structures can influence the mechanical–electrical behavior of cables, but the impact of alterations in the winding core structure on the mechanical–electrical behavior of superconducting cables remains unclear. This paper presents a 3D finite element model to predict the performance of three cables with different core structures when subjected to transverse compression and axial tension. The three cables analyzed are CORC (conductor-on-round-core), CORT (conductor-on-round-tube), and HFRC (conductor-on-spiral-tube). A parametric analysis is carried out by varying the core diameter and inner-to-outer diameter ratio. Results indicate that the CORT cable demonstrates better performance in transverse compression compared to the CORC cable, aligning with experimental data. Among the three cables, the HFRC cables exhibit the weakest resistance to transverse deformation. However, the HFRC cable demonstrates superior tensile deformation resistance compared to the CORT cable, provided that the transverse compression properties are maintained. Finite element results also show that the optimum inner-to-outer diameter ratios for achieving the best transverse compression performance are approximately 0.8 for CORT cables and 0.6 for HFRC cables. Meanwhile, the study explores the effect of structural changes in HTS cable winding cores on their electromagnetic properties. It recommends utilizing small tape gaps, lower frequencies, and spiral core construction to minimize eddy losses. The findings presented in this paper offer valuable insights for the commercialization and practical manufacturing of HTS cables.</p></div>","PeriodicalId":50892,"journal":{"name":"Acta Mechanica Solida Sinica","volume":"38 1","pages":"14 - 24"},"PeriodicalIF":2.0000,"publicationDate":"2024-10-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta Mechanica Solida Sinica","FirstCategoryId":"5","ListUrlMain":"https://link.springer.com/article/10.1007/s10338-024-00527-y","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"MATERIALS SCIENCE, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

Abstract

Research on the mechanical–electrical properties is crucial for designing and preparing high-temperature superconducting (HTS) cables. Various winding core structures can influence the mechanical–electrical behavior of cables, but the impact of alterations in the winding core structure on the mechanical–electrical behavior of superconducting cables remains unclear. This paper presents a 3D finite element model to predict the performance of three cables with different core structures when subjected to transverse compression and axial tension. The three cables analyzed are CORC (conductor-on-round-core), CORT (conductor-on-round-tube), and HFRC (conductor-on-spiral-tube). A parametric analysis is carried out by varying the core diameter and inner-to-outer diameter ratio. Results indicate that the CORT cable demonstrates better performance in transverse compression compared to the CORC cable, aligning with experimental data. Among the three cables, the HFRC cables exhibit the weakest resistance to transverse deformation. However, the HFRC cable demonstrates superior tensile deformation resistance compared to the CORT cable, provided that the transverse compression properties are maintained. Finite element results also show that the optimum inner-to-outer diameter ratios for achieving the best transverse compression performance are approximately 0.8 for CORT cables and 0.6 for HFRC cables. Meanwhile, the study explores the effect of structural changes in HTS cable winding cores on their electromagnetic properties. It recommends utilizing small tape gaps, lower frequencies, and spiral core construction to minimize eddy losses. The findings presented in this paper offer valuable insights for the commercialization and practical manufacturing of HTS cables.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
Acta Mechanica Solida Sinica
Acta Mechanica Solida Sinica 物理-材料科学:综合
CiteScore
3.80
自引率
9.10%
发文量
1088
审稿时长
9 months
期刊介绍: Acta Mechanica Solida Sinica aims to become the best journal of solid mechanics in China and a worldwide well-known one in the field of mechanics, by providing original, perspective and even breakthrough theories and methods for the research on solid mechanics. The Journal is devoted to the publication of research papers in English in all fields of solid-state mechanics and its related disciplines in science, technology and engineering, with a balanced coverage on analytical, experimental, numerical and applied investigations. Articles, Short Communications, Discussions on previously published papers, and invitation-based Reviews are published bimonthly. The maximum length of an article is 30 pages, including equations, figures and tables
期刊最新文献
Theoretical and Experimental Analysis of Nonlinear Large Tensile Deformation of Superelastic SMA-Based Honeycomb Structures Bending Characteristics of Folded Multi-celled Tubes with Square and Circular Section Geometries Molecular Dynamics Study on the Interactions of 1/2[110] Edge Dislocations with Voids and Ni3Al Precipitates in FCC Ni Stress Waves Propagation Along the Frictional Interface with a Micro-contact Level-Set-Based Topology Optimization of a Geometrically Nonlinear Structure Considering Thermo-mechanical Coupling Effect
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1