Part A: Implementing an Analyte Panel and Sampling Protocol for Quality Control in Mass Spectrometry Imaging

IF 1.8 3区 化学 Q4 BIOCHEMICAL RESEARCH METHODS Rapid Communications in Mass Spectrometry Pub Date : 2025-02-17 DOI:10.1002/rcm.9993
Quinn Mills, Russell R. Kibbe, Alexandria L. Sohn, Andrew J. Percy, Krista Backiel, David C. Muddiman
{"title":"Part A: Implementing an Analyte Panel and Sampling Protocol for Quality Control in Mass Spectrometry Imaging","authors":"Quinn Mills,&nbsp;Russell R. Kibbe,&nbsp;Alexandria L. Sohn,&nbsp;Andrew J. Percy,&nbsp;Krista Backiel,&nbsp;David C. Muddiman","doi":"10.1002/rcm.9993","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Rationale</h3>\n \n <p>While quality control (QC) and system suitability testing (SST) methods are commonly employed in mass spectrometry, the field of mass spectrometry imaging (MSI) currently lacks any universally accepted QC/SST protocols. These methods can prevent the loss of precious samples due to suboptimal instrument conditions and/or data quality, but they are more challenging to implement on MSI platforms. Herein, a panel of analytes is conveniently analyzed in a setup that reflects a typical MSI imaging experiment, and guidance is provided for downstream QC/SST evaluation.</p>\n </section>\n \n <section>\n \n <h3> Methods</h3>\n \n <p>The analyte panel will be commercially available and consists of three pairs of unlabeled (NAT) analytes and their stable isotope–labeled (SIL) analogues; a deviation from the standard procedure is also included, which incorporates a polymer to expand <i>m</i>/<i>z</i> coverage. The NAT three-plex (or four-plex with the added polymer) is analyzed as a droplet on a slide, and the SIL three-plex is doped into the electrospray solvent, isolating the NAT and SIL compounds to different source components. Datasets are collected on clean and compromised instruments to inform QC/SST software and later evaluate instrument conditions or isolated metrics of data quality.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>A procedure was created for QC/SST analysis on MSI platforms, which can be optionally paired with the freely available software Supervised Learning for Instrument Classification and Evaluation for Mass Spectrometry Imaging (SLICE-MSI) to classify the condition of the instrument. The SIL data may be monitored separately during imaging experiments for continuous evaluation of electrospray stability. The protocol highlights areas that may be adapted for other ionization sources for widespread use.</p>\n </section>\n \n <section>\n \n <h3> Conclusions</h3>\n \n <p>The protocol described herein uses a panel of NAT and SIL compounds to offer an objective and accurate determination of QC/SST on MSI platforms.</p>\n </section>\n </div>","PeriodicalId":225,"journal":{"name":"Rapid Communications in Mass Spectrometry","volume":"39 8","pages":""},"PeriodicalIF":1.8000,"publicationDate":"2025-02-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1002/rcm.9993","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Rapid Communications in Mass Spectrometry","FirstCategoryId":"92","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/rcm.9993","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

Abstract

Rationale

While quality control (QC) and system suitability testing (SST) methods are commonly employed in mass spectrometry, the field of mass spectrometry imaging (MSI) currently lacks any universally accepted QC/SST protocols. These methods can prevent the loss of precious samples due to suboptimal instrument conditions and/or data quality, but they are more challenging to implement on MSI platforms. Herein, a panel of analytes is conveniently analyzed in a setup that reflects a typical MSI imaging experiment, and guidance is provided for downstream QC/SST evaluation.

Methods

The analyte panel will be commercially available and consists of three pairs of unlabeled (NAT) analytes and their stable isotope–labeled (SIL) analogues; a deviation from the standard procedure is also included, which incorporates a polymer to expand m/z coverage. The NAT three-plex (or four-plex with the added polymer) is analyzed as a droplet on a slide, and the SIL three-plex is doped into the electrospray solvent, isolating the NAT and SIL compounds to different source components. Datasets are collected on clean and compromised instruments to inform QC/SST software and later evaluate instrument conditions or isolated metrics of data quality.

Results

A procedure was created for QC/SST analysis on MSI platforms, which can be optionally paired with the freely available software Supervised Learning for Instrument Classification and Evaluation for Mass Spectrometry Imaging (SLICE-MSI) to classify the condition of the instrument. The SIL data may be monitored separately during imaging experiments for continuous evaluation of electrospray stability. The protocol highlights areas that may be adapted for other ionization sources for widespread use.

Conclusions

The protocol described herein uses a panel of NAT and SIL compounds to offer an objective and accurate determination of QC/SST on MSI platforms.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
4.10
自引率
5.00%
发文量
219
审稿时长
2.6 months
期刊介绍: Rapid Communications in Mass Spectrometry is a journal whose aim is the rapid publication of original research results and ideas on all aspects of the science of gas-phase ions; it covers all the associated scientific disciplines. There is no formal limit on paper length ("rapid" is not synonymous with "brief"), but papers should be of a length that is commensurate with the importance and complexity of the results being reported. Contributions may be theoretical or practical in nature; they may deal with methods, techniques and applications, or with the interpretation of results; they may cover any area in science that depends directly on measurements made upon gaseous ions or that is associated with such measurements.
期刊最新文献
Adapting Automatic Water Samplers for the Isotopic Study of Rainfall at High Temporal Resolution Combining Laser-Induced Edition to Collision-Induced Sequencing of Digital Oligomers in a Single Gas-Phase Experiment. The Identification and Quantification of the Positional Isomers of Dimethylbipyridine by Ion Mobility Mass Spectrometry Analysis of Their Gas Phase Complexes Comparison of Electron Ionization Fragmentation Pathways for Regioisomeric Ethoxy and Methoxymethyl Substituted Benzoate Esters Determination of K Isotope Compositions in Sedimentary Rocks and Their Implications for Discriminating Sediment Origin
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1