Novel submucosal injection material comprising fully synthetic and self-assembling peptide solution in endoscopic submucosal dissection: A pilot study.

IF 2.2 Q3 GASTROENTEROLOGY & HEPATOLOGY Endoscopy International Open Pub Date : 2025-01-13 eCollection Date: 2025-01-01 DOI:10.1055/a-2487-2823
Kengo Kasuga, Keigo Sato, Ko Nakata, Hirohito Tanaka, Hiroko Hosaka, Shiko Kuribayashi, Yoji Takeuchi, Toshio Uraoka
{"title":"Novel submucosal injection material comprising fully synthetic and self-assembling peptide solution in endoscopic submucosal dissection: A pilot study.","authors":"Kengo Kasuga, Keigo Sato, Ko Nakata, Hirohito Tanaka, Hiroko Hosaka, Shiko Kuribayashi, Yoji Takeuchi, Toshio Uraoka","doi":"10.1055/a-2487-2823","DOIUrl":null,"url":null,"abstract":"<p><p>Endoscopic submucosal dissection (ESD) requires an injection solution to create a submucosal cushion for safe endoscopic resection. This study evaluated the safety and feasibility of a new injection solution (PuraLift) in ESD for early-stage gastrointestinal tumors. This prospective, single-arm, single-center pilot study included 11 patients with gastrointestinal neoplasms of the stomach (n = 5) or colorectum (n = 6) who underwent ESD. All patients underwent outpatient follow-up at week 4 to confirm presence or absence of adverse events (AEs). All underwent protocol treatment and post-treatment follow-up. None of the AEs were judged to have a cause-and-effect relationship with the study. Questionnaires to the operators who performed the protocol treatment and assistants who performed submucosal injections were evaluated in comparison with saline, and maintenance of mucosal lifting was long, comparable, and short (9/2/0). En bloc and R0 resections were achieved in all patients without intraprocedural AEs. Median size of the specimens was 40 mm (range, 20-70). Median excision time was 52 minutes (range, 22-130). Median volume of PuraLift was 32 mL (range, 22-130). No postoperative bleeding or delayed perforation was observed in any patient. The novel injectable material, PuraLift, can potentially ensure safe and feasible ESD.</p>","PeriodicalId":11671,"journal":{"name":"Endoscopy International Open","volume":"13 ","pages":"a24872823"},"PeriodicalIF":2.2000,"publicationDate":"2025-01-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11827729/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Endoscopy International Open","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1055/a-2487-2823","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"GASTROENTEROLOGY & HEPATOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Endoscopic submucosal dissection (ESD) requires an injection solution to create a submucosal cushion for safe endoscopic resection. This study evaluated the safety and feasibility of a new injection solution (PuraLift) in ESD for early-stage gastrointestinal tumors. This prospective, single-arm, single-center pilot study included 11 patients with gastrointestinal neoplasms of the stomach (n = 5) or colorectum (n = 6) who underwent ESD. All patients underwent outpatient follow-up at week 4 to confirm presence or absence of adverse events (AEs). All underwent protocol treatment and post-treatment follow-up. None of the AEs were judged to have a cause-and-effect relationship with the study. Questionnaires to the operators who performed the protocol treatment and assistants who performed submucosal injections were evaluated in comparison with saline, and maintenance of mucosal lifting was long, comparable, and short (9/2/0). En bloc and R0 resections were achieved in all patients without intraprocedural AEs. Median size of the specimens was 40 mm (range, 20-70). Median excision time was 52 minutes (range, 22-130). Median volume of PuraLift was 32 mL (range, 22-130). No postoperative bleeding or delayed perforation was observed in any patient. The novel injectable material, PuraLift, can potentially ensure safe and feasible ESD.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
Endoscopy International Open
Endoscopy International Open GASTROENTEROLOGY & HEPATOLOGY-
自引率
3.80%
发文量
270
期刊最新文献
Over-the-scope clips vs standard endoscopic interventions for first-line treatment of NVUGI bleeding: Meta-analysis of randomized trials. Pull-through endoscopic vacuum-assisted closure therapy for complicated leaks of the gastrointestinal tract: Novel technique. Endoscopic hemostasis with a self-expandable metal stent as bridge therapy for hemobilia. On-site ERCP availability and cholangitis outcomes: Retrospective cohort study. Endoscopic grading of gastric intestinal metaplasia using blue light imaging in a low-risk population: Multicenter cross-sectional validation study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1