Assessing the accuracy of the updated Fujifilm SILVAMP TB LAM II assay between lot numbers.

K Chikamatsu, Y Shimomura, A Osugi, S Mitarai
{"title":"Assessing the accuracy of the updated Fujifilm SILVAMP TB LAM II assay between lot numbers.","authors":"K Chikamatsu, Y Shimomura, A Osugi, S Mitarai","doi":"10.5588/ijtldopen.24.0449","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The Fujifilm SILVAMP TB LAM (FujiLAM) assay, a point-of-care test detecting urine-based lipoarabinomannans, has demonstrated notable diagnostic accuracy for TB. However, FujiLAM exhibits lot-to-lot variability, limiting its clinical use. A new version of the product, Fujifilm SILVAMP TB LAM II (FujiLAM II), was developed to address this issue. This study evaluated the lot-to-lot variability and diagnostic accuracy of the FujiLAM II.</p><p><strong>Methods: </strong>We assessed three lots of FujiLAM II using 158 biobanked, frozen urine specimens from people living with HIV (PLHIV): 72 TB-positive and 86 TB-negative, according to the microbiological reference standard.</p><p><strong>Results: </strong>Independent proportions of the results among the three FujiLAM II lots did not differ (Cochrane <i>Q</i> test: <i>P</i> > 0.37). Overall, sensitivities of the three FujiLAM II lots were 78.3%, 79.7% and 79.7%, and specificities were 92.9%, 93.0% and 93.0%, respectively. In patients with CD4 cell counts <200 cells/µL, sensitivities of the three FujiLAM II lots were 97.8%, 100% and 100%, and specificities were 91.7%, 91.8% and 91.8%, respectively.</p><p><strong>Conclusion: </strong>The FujiLAM II demonstrated no lot-to-lot variability and exhibited high sensitivity and specificity for TB diagnosis in patients with CD4 cell counts <200 cells/µL. The FujiLAM II enhanced reproducibility as a TB diagnostic tool in PLHIV.</p>","PeriodicalId":519984,"journal":{"name":"IJTLD open","volume":"2 2","pages":"96-100"},"PeriodicalIF":0.0000,"publicationDate":"2025-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11827673/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IJTLD open","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5588/ijtldopen.24.0449","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: The Fujifilm SILVAMP TB LAM (FujiLAM) assay, a point-of-care test detecting urine-based lipoarabinomannans, has demonstrated notable diagnostic accuracy for TB. However, FujiLAM exhibits lot-to-lot variability, limiting its clinical use. A new version of the product, Fujifilm SILVAMP TB LAM II (FujiLAM II), was developed to address this issue. This study evaluated the lot-to-lot variability and diagnostic accuracy of the FujiLAM II.

Methods: We assessed three lots of FujiLAM II using 158 biobanked, frozen urine specimens from people living with HIV (PLHIV): 72 TB-positive and 86 TB-negative, according to the microbiological reference standard.

Results: Independent proportions of the results among the three FujiLAM II lots did not differ (Cochrane Q test: P > 0.37). Overall, sensitivities of the three FujiLAM II lots were 78.3%, 79.7% and 79.7%, and specificities were 92.9%, 93.0% and 93.0%, respectively. In patients with CD4 cell counts <200 cells/µL, sensitivities of the three FujiLAM II lots were 97.8%, 100% and 100%, and specificities were 91.7%, 91.8% and 91.8%, respectively.

Conclusion: The FujiLAM II demonstrated no lot-to-lot variability and exhibited high sensitivity and specificity for TB diagnosis in patients with CD4 cell counts <200 cells/µL. The FujiLAM II enhanced reproducibility as a TB diagnostic tool in PLHIV.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Assessing the accuracy of the updated Fujifilm SILVAMP TB LAM II assay between lot numbers. Closing the gaps in childhood TB detection. Comparative efficacy of tetracyclines against isolates of Mycobacterium avium complex. Efficacy and safety data on pretomanid for drug-resistant TB. Ending the TB epidemic - what can we learn from the HIV epidemic?
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1