Long-Term Clinical Outcomes and Anterior Segment Optical Coherence Tomography Findings After Artificial Endothelial Replacement Membrane Implantation.

IF 1.9 3区 医学 Q2 OPHTHALMOLOGY Cornea Pub Date : 2025-02-18 DOI:10.1097/ICO.0000000000003835
Luigi Fontana, Natalie di Geronimo, Piera Versura, Antonio Moramarco
{"title":"Long-Term Clinical Outcomes and Anterior Segment Optical Coherence Tomography Findings After Artificial Endothelial Replacement Membrane Implantation.","authors":"Luigi Fontana, Natalie di Geronimo, Piera Versura, Antonio Moramarco","doi":"10.1097/ICO.0000000000003835","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>This study examines the long-term clinical outcomes of an artificial endothelial replacement membrane implant used to treat corneal edema. It also explores the interaction between the device and the posterior surface of the cornea.</p><p><strong>Methods: </strong>Patients suffering from late endothelial keratoplasty failure (5 patients) or bullous keratopathy (2 patients) after multiple surgeries underwent EndoArt (EyeYon Medical, Israel) implantation. Before surgery and at 1-, 3-, 6-, 12-, 18-, and 24-month intervals, corrected distance visual acuity and central corneal thickness were measured. High-resolution anterior segment optical coherence tomography images were analyzed at each interval to detect device detachment and evaluate the implant interaction with the corneal tissue over time.</p><p><strong>Results: </strong>Corrected distance visual acuity improved from a mean of 1.32 ± 0.23 (logarithm of the Minimum Angle of Resolution) preoperatively to 0.95 ± 0.28 (logarithm of the Minimum Angle of Resolution) 2 years after surgery (P = 0.03). Central corneal thickness significantly decreased from 805 ± 131 μm preoperatively to 577 ± 90 μm postoperatively (P = 0.002). Four of the 7 patients experienced device detachment, requiring 1 or more rebubblings to achieve stable implant adhesion. Anterior segment optical coherence tomography showed annular fibrosis developing between the device margin and the host cornea in most patients, particularly those who had never experienced detachment.</p><p><strong>Conclusions: </strong>This study suggests that EndoArt is effective in the long term for improving corneal transparency and visual acuity in patients with chronic corneal edema with a limited prognosis for endothelial keratoplasty. The formation of fibrotic tissue between the periphery of the device and the host cornea may explain the strong adhesion of the implant.</p>","PeriodicalId":10710,"journal":{"name":"Cornea","volume":" ","pages":""},"PeriodicalIF":1.9000,"publicationDate":"2025-02-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cornea","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/ICO.0000000000003835","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: This study examines the long-term clinical outcomes of an artificial endothelial replacement membrane implant used to treat corneal edema. It also explores the interaction between the device and the posterior surface of the cornea.

Methods: Patients suffering from late endothelial keratoplasty failure (5 patients) or bullous keratopathy (2 patients) after multiple surgeries underwent EndoArt (EyeYon Medical, Israel) implantation. Before surgery and at 1-, 3-, 6-, 12-, 18-, and 24-month intervals, corrected distance visual acuity and central corneal thickness were measured. High-resolution anterior segment optical coherence tomography images were analyzed at each interval to detect device detachment and evaluate the implant interaction with the corneal tissue over time.

Results: Corrected distance visual acuity improved from a mean of 1.32 ± 0.23 (logarithm of the Minimum Angle of Resolution) preoperatively to 0.95 ± 0.28 (logarithm of the Minimum Angle of Resolution) 2 years after surgery (P = 0.03). Central corneal thickness significantly decreased from 805 ± 131 μm preoperatively to 577 ± 90 μm postoperatively (P = 0.002). Four of the 7 patients experienced device detachment, requiring 1 or more rebubblings to achieve stable implant adhesion. Anterior segment optical coherence tomography showed annular fibrosis developing between the device margin and the host cornea in most patients, particularly those who had never experienced detachment.

Conclusions: This study suggests that EndoArt is effective in the long term for improving corneal transparency and visual acuity in patients with chronic corneal edema with a limited prognosis for endothelial keratoplasty. The formation of fibrotic tissue between the periphery of the device and the host cornea may explain the strong adhesion of the implant.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
Cornea
Cornea 医学-眼科学
CiteScore
5.20
自引率
10.70%
发文量
354
审稿时长
3-6 weeks
期刊介绍: For corneal specialists and for all general ophthalmologists with an interest in this exciting subspecialty, Cornea brings together the latest clinical and basic research on the cornea and the anterior segment of the eye. Each volume is peer-reviewed by Cornea''s board of world-renowned experts and fully indexed in archival format. Your subscription brings you the latest developments in your field and a growing library of valuable professional references. Sponsored by The Cornea Society which was founded as the Castroviejo Cornea Society in 1975.
期刊最新文献
Descemet Membrane Endothelial Keratoplasty With and Without Graft Deswelling: A Prospective Clinical Study. Prophylactic Therapy for Long-Term Ocular Discomfort After Cataract Surgery. Corneal Backscatter, Pachymetric Indices, and Ectasia Indices for the Assessment of Fuchs Endothelial Corneal Dystrophy. Patient-Reported Outcomes and Higher Order Aberrations Following Topography-Guided Femtosecond Laser-Assisted In Situ Keratomileusis. The Impact of Donor History of Sleep Apnea on Corneal Tissue Evaluation Parameters.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1