Real-Time Performance Monitoring of Digital X-Ray Diagnostic Equipment Prior to Patient Admission

IF 0.4 4区 物理与天体物理 Q4 PHYSICS, NUCLEAR Physics of Atomic Nuclei Pub Date : 2025-02-19 DOI:10.1134/S1063778824100016
M. R. Akhmedzyanova, M. I. Zelikman, S. A. Kruchinin, Z. A. Lantukh, I. V. Soldatov, Yu. A. Vasilev, Yu. V. Druzhinina, A. O. Tolokonskiy
{"title":"Real-Time Performance Monitoring of Digital X-Ray Diagnostic Equipment Prior to Patient Admission","authors":"M. R. Akhmedzyanova,&nbsp;M. I. Zelikman,&nbsp;S. A. Kruchinin,&nbsp;Z. A. Lantukh,&nbsp;I. V. Soldatov,&nbsp;Yu. A. Vasilev,&nbsp;Yu. V. Druzhinina,&nbsp;A. O. Tolokonskiy","doi":"10.1134/S1063778824100016","DOIUrl":null,"url":null,"abstract":"<p>In order to provide high-quality performance of X-ray diagnostic equipment and easy malfunction detection and maintenance, radiographer-oriented routine checks should be carried out. The aim of this article was to develop a simplified method for periodic technical inspection of X-ray machines and stability testing of equipment without using a specialized test object. The article presents the results of a theoretical and experimental study of a method of real-time performance monitoring of an X-ray diagnostic apparatus with a digital receiver with continuous operation of the department. The proposed method can be used for evaluation of the performance of a digital X-ray diagnostic apparatus by determining the parameters of a clear field image (an image that is obtained when there is no test object in the input plane of the receiver) and the subsequent evaluation of the output signal-to-noise ratio and the receiver transmission coefficient. An algorithm for the real-time performance monitoring of the digital X-ray diagnostic apparatus has been developed. The acceptable parameter variation ranges of key image parameters have been established using an expert method. The study shows the performance of the method and its simplicity.</p>","PeriodicalId":728,"journal":{"name":"Physics of Atomic Nuclei","volume":"87 10","pages":"1560 - 1566"},"PeriodicalIF":0.4000,"publicationDate":"2025-02-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Physics of Atomic Nuclei","FirstCategoryId":"101","ListUrlMain":"https://link.springer.com/article/10.1134/S1063778824100016","RegionNum":4,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"PHYSICS, NUCLEAR","Score":null,"Total":0}
引用次数: 0

Abstract

In order to provide high-quality performance of X-ray diagnostic equipment and easy malfunction detection and maintenance, radiographer-oriented routine checks should be carried out. The aim of this article was to develop a simplified method for periodic technical inspection of X-ray machines and stability testing of equipment without using a specialized test object. The article presents the results of a theoretical and experimental study of a method of real-time performance monitoring of an X-ray diagnostic apparatus with a digital receiver with continuous operation of the department. The proposed method can be used for evaluation of the performance of a digital X-ray diagnostic apparatus by determining the parameters of a clear field image (an image that is obtained when there is no test object in the input plane of the receiver) and the subsequent evaluation of the output signal-to-noise ratio and the receiver transmission coefficient. An algorithm for the real-time performance monitoring of the digital X-ray diagnostic apparatus has been developed. The acceptable parameter variation ranges of key image parameters have been established using an expert method. The study shows the performance of the method and its simplicity.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
病人入院前数字x射线诊断设备的实时性能监测
为了提供高质量的x射线诊断设备性能,便于故障检测和维护,应进行面向放射技师的例行检查。本文的目的是开发一种简化的方法,用于x光机的定期技术检查和设备的稳定性测试,而不使用专门的测试对象。本文介绍了用数字接收机对科室连续运行的x射线诊断仪进行实时性能监测的理论和实验研究结果。所提出的方法可用于通过确定清场图像(接收器输入平面内没有测试对象时获得的图像)的参数以及随后对输出信噪比和接收器传输系数的评估来评估数字x射线诊断设备的性能。提出了一种用于数字x射线诊断仪性能实时监测的算法。利用专家方法确定了关键图像参数的可接受参数变化范围。研究表明了该方法的有效性和简单性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Physics of Atomic Nuclei
Physics of Atomic Nuclei 物理-物理:核物理
CiteScore
0.60
自引率
25.00%
发文量
56
审稿时长
3-6 weeks
期刊介绍: Physics of Atomic Nuclei is a journal that covers experimental and theoretical studies of nuclear physics: nuclear structure, spectra, and properties; radiation, fission, and nuclear reactions induced by photons, leptons, hadrons, and nuclei; fundamental interactions and symmetries; hadrons (with light, strange, charm, and bottom quarks); particle collisions at high and superhigh energies; gauge and unified quantum field theories, quark models, supersymmetry and supergravity, astrophysics and cosmology.
期刊最新文献
Simulation Results of Dry Deposition of Radioactive Aerosols in the Arctic Regions of the Far North Nonlinear Finite-Difference Scheme with a Limiter for Numerical Modeling of Radiation Transport Processes On a Method of Constructing an Irregular Grid for the One-Dimensional Convection-Diffusion Equation Studies of Radiation and Protective Properties of Natural Minerals in Vietnam Thermohydraulic Calculation of the Design of an Irradiation Device for In-Reactor Tests of VVER-SCP Fuel Rod Models with Cores Based on Nuclear Fuel Swelling Simulators
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1