Risk factors in self-reported dissatisfied patients implanted with various presbyopia-correcting intraocular lenses after cataract surgery.

IF 1.7 4区 医学 Q3 OPHTHALMOLOGY BMC Ophthalmology Pub Date : 2025-02-19 DOI:10.1186/s12886-025-03912-4
Woosung Jeon, Chang Ho Yoon, Joo Youn Oh, Hyuk Jin Choi, Mee Kum Kim
{"title":"Risk factors in self-reported dissatisfied patients implanted with various presbyopia-correcting intraocular lenses after cataract surgery.","authors":"Woosung Jeon, Chang Ho Yoon, Joo Youn Oh, Hyuk Jin Choi, Mee Kum Kim","doi":"10.1186/s12886-025-03912-4","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>This study aimed to investigate the self-reported dissatisfaction rates and associated risk factors among patients who underwent cataract surgery using different types of presbyopia-correcting intraocular lenses (IOLs).</p><p><strong>Methods: </strong>This retrospective case-control study analyzed the medical records in 340 eyes from 211 cataract surgery patients with presbyopia-correcting IOLs. The analyzed IOL types included bifocal (ReSTOR®), trifocal (PanOptix®), and extended depth-of-focus (EDOF; Symfony®) IOLs. The rates of self-reported dissatisfaction related to vision or photic disturbances were compared between these IOLs. Various factors, including sex, age, preoperative visual acuity and refractive status, and biometric indices, were analyzed to identify potential risk factors for dissatisfaction.</p><p><strong>Results: </strong>The overall dissatisfaction rate was 18.5% (63/340). Among the IOL types, Symfony®-implanted eyes had the highest rate of near-vision dissatisfaction, while PanOptix®-implanted eyes showed similar proportions of photic disturbances and near-vision discomfort. The major risk factor identified for overall dissatisfaction, regardless of IOL type, was preoperative myopia, which aligns with the risk factor for near discomfort. Meanwhile, the risk factors for photic phenomena were revealed to be thinner corneal thickness and greater corneal astigmatism. By IOL types, preoperative myopia caused near-vision discomfort in Symfony® eyes, whereas greater corneal astigmatism and thinner corneas were linked to photic disturbances in PanOptix® eyes.</p><p><strong>Conclusions: </strong>It suggests that near-vision discomfort is related to myopic factors, whereas photic disturbances are associated with ocular aberrations. The types of dissatisfaction vary depending on the designs of presbyopia-correcting IOLs.</p><p><strong>Trial registration: </strong>This retrospective study adhered to the principles of the Declaration of Helsinki and was approved by the Institutional Review Board of the Seoul National University Hospital on March 13, 2023 (IRB No: 2303-025-1409).</p>","PeriodicalId":9058,"journal":{"name":"BMC Ophthalmology","volume":"25 1","pages":"82"},"PeriodicalIF":1.7000,"publicationDate":"2025-02-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11837369/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMC Ophthalmology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s12886-025-03912-4","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background: This study aimed to investigate the self-reported dissatisfaction rates and associated risk factors among patients who underwent cataract surgery using different types of presbyopia-correcting intraocular lenses (IOLs).

Methods: This retrospective case-control study analyzed the medical records in 340 eyes from 211 cataract surgery patients with presbyopia-correcting IOLs. The analyzed IOL types included bifocal (ReSTOR®), trifocal (PanOptix®), and extended depth-of-focus (EDOF; Symfony®) IOLs. The rates of self-reported dissatisfaction related to vision or photic disturbances were compared between these IOLs. Various factors, including sex, age, preoperative visual acuity and refractive status, and biometric indices, were analyzed to identify potential risk factors for dissatisfaction.

Results: The overall dissatisfaction rate was 18.5% (63/340). Among the IOL types, Symfony®-implanted eyes had the highest rate of near-vision dissatisfaction, while PanOptix®-implanted eyes showed similar proportions of photic disturbances and near-vision discomfort. The major risk factor identified for overall dissatisfaction, regardless of IOL type, was preoperative myopia, which aligns with the risk factor for near discomfort. Meanwhile, the risk factors for photic phenomena were revealed to be thinner corneal thickness and greater corneal astigmatism. By IOL types, preoperative myopia caused near-vision discomfort in Symfony® eyes, whereas greater corneal astigmatism and thinner corneas were linked to photic disturbances in PanOptix® eyes.

Conclusions: It suggests that near-vision discomfort is related to myopic factors, whereas photic disturbances are associated with ocular aberrations. The types of dissatisfaction vary depending on the designs of presbyopia-correcting IOLs.

Trial registration: This retrospective study adhered to the principles of the Declaration of Helsinki and was approved by the Institutional Review Board of the Seoul National University Hospital on March 13, 2023 (IRB No: 2303-025-1409).

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
BMC Ophthalmology
BMC Ophthalmology OPHTHALMOLOGY-
CiteScore
3.40
自引率
5.00%
发文量
441
审稿时长
6-12 weeks
期刊介绍: BMC Ophthalmology is an open access, peer-reviewed journal that considers articles on all aspects of the prevention, diagnosis and management of eye disorders, as well as related molecular genetics, pathophysiology, and epidemiology.
期刊最新文献
Effect of factors on the space between the posterior capsule and IOL. Comparative evaluation of phacoemulsification combined with goniosynechi-alysis with goniotomy versus trabeculectomy in patients with angle-closure glaucoma and cataract. Correlation of contrast sensitivity at low spatial frequencies with myopic shift in Chinese children. Management of fracture and displacement of a previously successful bilateral transconjunctival ab-externo XEN gel stent: a case report. Diurnal variations in corneal biomechanics in healthy young adults.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1