Quantitative ultrasound analysis for non-invasive assessment of hepatic steatosis in metabolic dysfunction-associated steatotic liver disease.

Yunling Fan, Kailing Chen, Qiannan Zhao, Haohao Yin, Yuli Zhu, Huixiong Xu
{"title":"Quantitative ultrasound analysis for non-invasive assessment of hepatic steatosis in metabolic dysfunction-associated steatotic liver disease.","authors":"Yunling Fan, Kailing Chen, Qiannan Zhao, Haohao Yin, Yuli Zhu, Huixiong Xu","doi":"10.1177/13860291241304057","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To evaluate the diagnostic performance of novel tissue attenuation imaging (TAI) and tissue scatter distribution imaging (TSI) tools in detecting and grading hepatic steatosis using controlled attenuation parameter (CAP) as reference standard.</p><p><strong>Methods: </strong>A total of 185 participants with suspected metabolic dysfunction-associated steatotic liver disease (MASLD) were prospectively enrolled, and all underwent CAP and quantitative ultrasound (QUS) testing. Correlations between CAP, biological data, TAI and TSI were assessed. The influence factors of TAI and TSI as well as the diagnostic performance of TAI and TSI in detecting hepatic steatosis were evaluated.</p><p><strong>Results: </strong>The QUS parameters (TAI and TSI) showed good intra-observer reliability with ICC of 0.972 and 0.777, respectively. The correlation of CAP with TAI was higher than that of TSI (0.724 vs 0.360, <i>P </i>< 0.05). Multivariate Regression analysis showed that CAP was an important influence factor of TAI and TSI (<i>P </i>< 0.001). The area under the ROC curve (CAP > 250 dB/m) of TAI and TSI tools for detecting hepatic steatosis was 0.876 (95% CI: 0.813-0.923; <i>P </i>< 0.0001) and 0.797(95% CI: 0.724-0.857; <i>P </i>< 0.001), respectively; the sensitivity was 67.18% and 83.21%, the specificity was 95.65% and 69.57%, and the cut-off values were 0.93 dB/cm/MHz and 91.28, respectively. When TAI and TSI were combined, the area under the ROC curve was 0.881, with a sensitivity of 80.92% and a specificity of 82.61%. The Delong test showed that the combined diagnosis of TAI and TSI was equivalent to the use of TAI alone (<i>P </i>> 0.05).</p><p><strong>Conclusion: </strong>TAI and TSI provided good intra-observer reliability, correlated well with CAP, and helped to detect and stage hepatic steatosis.</p>","PeriodicalId":93943,"journal":{"name":"Clinical hemorheology and microcirculation","volume":" ","pages":"13860291241304057"},"PeriodicalIF":0.0000,"publicationDate":"2025-02-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical hemorheology and microcirculation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/13860291241304057","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: To evaluate the diagnostic performance of novel tissue attenuation imaging (TAI) and tissue scatter distribution imaging (TSI) tools in detecting and grading hepatic steatosis using controlled attenuation parameter (CAP) as reference standard.

Methods: A total of 185 participants with suspected metabolic dysfunction-associated steatotic liver disease (MASLD) were prospectively enrolled, and all underwent CAP and quantitative ultrasound (QUS) testing. Correlations between CAP, biological data, TAI and TSI were assessed. The influence factors of TAI and TSI as well as the diagnostic performance of TAI and TSI in detecting hepatic steatosis were evaluated.

Results: The QUS parameters (TAI and TSI) showed good intra-observer reliability with ICC of 0.972 and 0.777, respectively. The correlation of CAP with TAI was higher than that of TSI (0.724 vs 0.360, P < 0.05). Multivariate Regression analysis showed that CAP was an important influence factor of TAI and TSI (P < 0.001). The area under the ROC curve (CAP > 250 dB/m) of TAI and TSI tools for detecting hepatic steatosis was 0.876 (95% CI: 0.813-0.923; P < 0.0001) and 0.797(95% CI: 0.724-0.857; P < 0.001), respectively; the sensitivity was 67.18% and 83.21%, the specificity was 95.65% and 69.57%, and the cut-off values were 0.93 dB/cm/MHz and 91.28, respectively. When TAI and TSI were combined, the area under the ROC curve was 0.881, with a sensitivity of 80.92% and a specificity of 82.61%. The Delong test showed that the combined diagnosis of TAI and TSI was equivalent to the use of TAI alone (P > 0.05).

Conclusion: TAI and TSI provided good intra-observer reliability, correlated well with CAP, and helped to detect and stage hepatic steatosis.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Clinical application of subharmonic aided pressure estimation (SHAPE) in the assessment of portal hypertension in patients with decompensated cirrhosis: A pilot study. Quantitative ultrasound analysis for non-invasive assessment of hepatic steatosis in metabolic dysfunction-associated steatotic liver disease. Prevention of ischemia-reperfusion injury on the porcine model of supra-renal aortic clamp by sulodexide. The modulation of endothelial glycocalyx by sulodexide on the porcine model of enzymatic endothelial glycocalyx damage - a pilot study. Development of a nomogram incorporating BRAF-V600E to predict central lymph node metastasis in papillary thyroid carcinoma.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1