Efficacy of ultrasonography and mammography in detecting features of breast cancer.

IF 1 Q4 PRIMARY HEALTH CARE Journal of Family Medicine and Primary Care Pub Date : 2025-01-01 Epub Date: 2025-01-13 DOI:10.4103/jfmpc.jfmpc_1225_24
Sultan Abdulwadoud Alshoabi, Amal A Alareqi, Moawia Gameraddin, Awadia Gareeballah, Kamal D Alsultan, Amel F Alzain
{"title":"Efficacy of ultrasonography and mammography in detecting features of breast cancer.","authors":"Sultan Abdulwadoud Alshoabi, Amal A Alareqi, Moawia Gameraddin, Awadia Gareeballah, Kamal D Alsultan, Amel F Alzain","doi":"10.4103/jfmpc.jfmpc_1225_24","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Breast cancer (BC) is considered one of the most commonly diagnosed cancers. Early detection is critical for effective management. This study aims to assess the utility of ultrasonography (US) and mammography (MG) in detecting BC features.</p><p><strong>Methods: </strong>This retrospective cross-sectional study involved the electronic records of 263 female patients diagnosed with BC. The mean age was 45.71 ± 12.25 years (17-90 years). A cross-tabulation test was performed to correlate the presence of each malignant feature (Yes/No) on both US and MG and the final ultrasonography diagnosis (benign/malignant). The compatibility between the presence of each feature on both imaging techniques was measured by the percentage of agreement in reporting the feature that was reported as Kappa. The sensitivity and specificity for each feature were calculated, and the receiver operating characteristic curve was used to measure the area under the curve for each feature on both modalities.</p><p><strong>Results: </strong>The strong compatibility between the two techniques was 87.1%, 94.29%, 66.92%, 79.85%, 77.56%, 77.18, and 79.84% for irregular shape, uncircumscribed, spiculated margins, tissue distortion, nipple retraction, skin thickening, and the presence of lymphadenopathy, respectively (<i>P</i> < 0.001). Boxplots show that the sensitivity of the US ranged from 37% to 95%, and the specificity ranged from 27% to 91%. However, MG's sensitivity ranged from 44% to 93%, and the specificity ranged from 36% to 73%.</p><p><strong>Conclusion: </strong>US and MG images show similar morphological changes, enhancing diagnostic accuracy in breast lesions. US characterizes echogenicity, provides real-time imaging, and uses color and pulsed Doppler techniques for vascularity and lymphadenopathy detection, while MG is better for identifying different calcification types.</p>","PeriodicalId":15856,"journal":{"name":"Journal of Family Medicine and Primary Care","volume":"14 1","pages":"341-347"},"PeriodicalIF":1.0000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11844950/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Family Medicine and Primary Care","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/jfmpc.jfmpc_1225_24","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/13 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"PRIMARY HEALTH CARE","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: Breast cancer (BC) is considered one of the most commonly diagnosed cancers. Early detection is critical for effective management. This study aims to assess the utility of ultrasonography (US) and mammography (MG) in detecting BC features.

Methods: This retrospective cross-sectional study involved the electronic records of 263 female patients diagnosed with BC. The mean age was 45.71 ± 12.25 years (17-90 years). A cross-tabulation test was performed to correlate the presence of each malignant feature (Yes/No) on both US and MG and the final ultrasonography diagnosis (benign/malignant). The compatibility between the presence of each feature on both imaging techniques was measured by the percentage of agreement in reporting the feature that was reported as Kappa. The sensitivity and specificity for each feature were calculated, and the receiver operating characteristic curve was used to measure the area under the curve for each feature on both modalities.

Results: The strong compatibility between the two techniques was 87.1%, 94.29%, 66.92%, 79.85%, 77.56%, 77.18, and 79.84% for irregular shape, uncircumscribed, spiculated margins, tissue distortion, nipple retraction, skin thickening, and the presence of lymphadenopathy, respectively (P < 0.001). Boxplots show that the sensitivity of the US ranged from 37% to 95%, and the specificity ranged from 27% to 91%. However, MG's sensitivity ranged from 44% to 93%, and the specificity ranged from 36% to 73%.

Conclusion: US and MG images show similar morphological changes, enhancing diagnostic accuracy in breast lesions. US characterizes echogenicity, provides real-time imaging, and uses color and pulsed Doppler techniques for vascularity and lymphadenopathy detection, while MG is better for identifying different calcification types.

Abstract Image

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
超声与乳房x光检查对乳腺癌特征的检测效果。
乳腺癌(BC)被认为是最常诊断的癌症之一。早期发现对有效管理至关重要。本研究旨在评估超声(US)和乳房x线摄影(MG)在检测BC特征方面的应用。方法:本回顾性横断面研究涉及263例诊断为BC的女性患者的电子记录。平均年龄(45.71±12.25)岁(17 ~ 90岁)。进行交叉表列测试,将US和MG上每个恶性特征(是/否)的存在与最终超声诊断(良性/恶性)相关联。两种成像技术中存在的每个特征之间的兼容性通过报告被报告为Kappa的特征的一致性百分比来衡量。计算每个特征的敏感性和特异性,并使用受试者工作特征曲线来测量两种模式下每个特征的曲线下面积。结果:对于形状不规则、边缘无边界、毛刺状、组织变形、乳头内缩、皮肤增厚、存在淋巴结病变,两种方法的相容性分别为87.1%、94.29%、66.92%、79.85%、77.56%、77.18%和79.84% (P < 0.001)。箱线图显示US的敏感性为37% ~ 95%,特异性为27% ~ 91%。然而,MG的敏感性为44% ~ 93%,特异性为36% ~ 73%。结论:US和MG表现出相似的形态学改变,提高了乳腺病变的诊断准确性。超声具有回声性,提供实时成像,并使用彩色和脉冲多普勒技术检测血管和淋巴结病变,而MG更能识别不同的钙化类型。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
7.10%
发文量
884
审稿时长
40 weeks
期刊最新文献
Demographic and conceptual disparities in systemic lupus erythematosus: A comparative analysis from Riyadh, Saudi Arabia. Understanding fathers' help-seeking: A scoping review. Understanding menstrual health perceptions, practices, and premenstrual symptomatology among college girls in urban Chandigarh: A cross-sectional study. Dialyzer-associated thrombocytopenia: Case report and brief review of the literature. Wrist circumference (WrC) in early gestation: A novel anthropometric predictor of gestational diabetes mellitus (GDM) in Asian Indian women.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1