A Case of Laparoscopic Resection of Gastric Cancer Using Novel Laparoscopic Fluorescence Spectrum System and Near-Infrared Fluorescent Clips.

IF 0.7 Q4 SURGERY Surgical Case Reports Pub Date : 2025-01-01 Epub Date: 2025-02-01 DOI:10.70352/scrj.cr.24-0028
Shion Uemura, Yuma Ebihara, Kazuya Konishi, Satoshi Hirano
{"title":"A Case of Laparoscopic Resection of Gastric Cancer Using Novel Laparoscopic Fluorescence Spectrum System and Near-Infrared Fluorescent Clips.","authors":"Shion Uemura, Yuma Ebihara, Kazuya Konishi, Satoshi Hirano","doi":"10.70352/scrj.cr.24-0028","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>In laparoscopic gastrectomy, accurate marking of the lesion site is essential in determining the resection line of the stomach, owing to the lack of haptics and the direct link between negative pathological margins and prognosis. Intraoperative endoscopy may require personnel and prolong the operation time, whereas preoperative endoscopic tattooing using India ink faces problems related to the spread of ink and visibility. ZEOCLIP FS (Zeon Medical, Tokyo, Japan) is a clip made of fluorescent resin, covered by insurance since March 2019. It can be visualized from the serosal side using a near-infrared scope; however, its weak fluorescence intensity often poses viewing difficulties. Lumifinder (ADVANTEST, Tokyo, Japan) is a laparoscopic fluorescence spectrum system available for clinical use since February 2023. It can measure fluorescence intensity using a near-infrared laser and detect weak fluorescent signals. We report a case of gastric cancer in which the location of the lesion was confirmed intraoperatively using ZEOCLIP FS and Lumifinder.</p><p><strong>Case presentation: </strong>A man in his 80s was diagnosed with gastric cancer following an examination for anemia. Two lesions were found: a 0-IIc type (cT1) at the lesser curvature of the gastric angle and a type 1 tumor (cT2) at the anterior wall of the upper gastric body. The preoperative assessment indicated no lymph node or distant metastasis. The tumor was diagnosed as cStage I and laparoscopic distal gastrectomy was planned. Two ZEOCLIP FS clips were placed on the oral side of the tumor on the anterior wall of the upper gastric body on the day before surgery. During surgery, fluorescent signals from the clips were detected using Lumifinder, enabling easy confirmation of the lesion location and determination of the gastric resection line.</p><p><strong>Conclusions: </strong>The combined use of ZEOCLIP FS and Lumifinder was a useful new method for identifying the appropriate resection line of the stomach. We plan to evaluate this method further in additional cases to enhance the detection efficacy.</p>","PeriodicalId":22096,"journal":{"name":"Surgical Case Reports","volume":"11 1","pages":""},"PeriodicalIF":0.7000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11842931/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Surgical Case Reports","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.70352/scrj.cr.24-0028","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/2/1 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: In laparoscopic gastrectomy, accurate marking of the lesion site is essential in determining the resection line of the stomach, owing to the lack of haptics and the direct link between negative pathological margins and prognosis. Intraoperative endoscopy may require personnel and prolong the operation time, whereas preoperative endoscopic tattooing using India ink faces problems related to the spread of ink and visibility. ZEOCLIP FS (Zeon Medical, Tokyo, Japan) is a clip made of fluorescent resin, covered by insurance since March 2019. It can be visualized from the serosal side using a near-infrared scope; however, its weak fluorescence intensity often poses viewing difficulties. Lumifinder (ADVANTEST, Tokyo, Japan) is a laparoscopic fluorescence spectrum system available for clinical use since February 2023. It can measure fluorescence intensity using a near-infrared laser and detect weak fluorescent signals. We report a case of gastric cancer in which the location of the lesion was confirmed intraoperatively using ZEOCLIP FS and Lumifinder.

Case presentation: A man in his 80s was diagnosed with gastric cancer following an examination for anemia. Two lesions were found: a 0-IIc type (cT1) at the lesser curvature of the gastric angle and a type 1 tumor (cT2) at the anterior wall of the upper gastric body. The preoperative assessment indicated no lymph node or distant metastasis. The tumor was diagnosed as cStage I and laparoscopic distal gastrectomy was planned. Two ZEOCLIP FS clips were placed on the oral side of the tumor on the anterior wall of the upper gastric body on the day before surgery. During surgery, fluorescent signals from the clips were detected using Lumifinder, enabling easy confirmation of the lesion location and determination of the gastric resection line.

Conclusions: The combined use of ZEOCLIP FS and Lumifinder was a useful new method for identifying the appropriate resection line of the stomach. We plan to evaluate this method further in additional cases to enhance the detection efficacy.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
218
审稿时长
13 weeks
期刊最新文献
Acute Myocardial Infarction Caused by Pulmonary Vein Stump Thrombosis after Thoracoscopic Left Upper Lobectomy. A Case of Graves' Disease in a Patient with Kartagener's Syndrome (Complete Visceral Inversion, Chronic Sinusitis, and Bronchiectasis). A Case Report of Severe Thrombocytopenic Purpura during Neoadjuvant Pembrolizumab Administration for Triple-Negative Breast Cancer. Omental Torsion Diagnosed and Treated with Single-Incision Laparoscopic Surgery in 2 Pediatric Patients: A Case Report. Pulmonary Lobectomy for Chronic Pulmonary Vein Occlusion after Catheter Ablation for Atrial Fibrillation: A Case Report and Literature Review.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1