Multicenter study of HPC coated p48 and p64 flow diverters for treatment of intracranial aneurysms under dual antiplatelet therapy.

IF 1.5 4区 医学 Q4 CLINICAL NEUROLOGY Interventional Neuroradiology Pub Date : 2025-02-24 DOI:10.1177/15910199251318066
Lukas Goertz, Charlotte S Weyland, Omid Nikoubashman, Franziska Bürkle, Frederic de Beukelaer, Eberhard Siebert, Christian Gronemann, Sophia Hohenstatt, Franziska Dorn, Georg Bohner, Martin Wiesmann, Hani Ridwan, Christoph Kabbasch
{"title":"Multicenter study of HPC coated p48 and p64 flow diverters for treatment of intracranial aneurysms under dual antiplatelet therapy.","authors":"Lukas Goertz, Charlotte S Weyland, Omid Nikoubashman, Franziska Bürkle, Frederic de Beukelaer, Eberhard Siebert, Christian Gronemann, Sophia Hohenstatt, Franziska Dorn, Georg Bohner, Martin Wiesmann, Hani Ridwan, Christoph Kabbasch","doi":"10.1177/15910199251318066","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>Phenox flow diverters (p64 and its smaller vessel variant p48) represent an established treatment option for intracranial aneurysms. This study evaluates the safety and efficacy of the new generation of these devices with an additional antithrombotic surface coating (HPC).</p><p><strong>Methods: </strong>Consecutive patients treated between 2020 and 2023 at three institutions were retrospectively reviewed for aneurysm characteristics, procedural details, complications, and angiographic outcomes.</p><p><strong>Results: </strong>Sixty-one patients (mean age 56 years) were treated for 61 aneurysms. The mean aneurysm size was 8.3 ± 4.9 mm, 12 (19.7%) were ruptured, 16 (26.2%) were recurrent after previous treatment, 10 (16.4%) were located in the posterior circulation, and 7 (11.5%) had nonsaccular morphology. All procedures were technically successful, with a single device sufficient in 60/61 (98%) cases. Delivery problems included device twisting in one case and incomplete proximal opening in another. Additional angioplasty was performed in 3/61 (4.9%) procedures and additional coiling in 4 (6.6%). There were 3 (4.9%) major events (1 thromboembolic ischemic stroke, 1 fatal intracranial hemorrhage, and 1 delayed aneurysm rupture) and 6 (9.8%) minor strokes. Follow up at a mean of 6 months showed complete occlusion in 33/42 (79%) aneurysms, neck remnants in 5 (12%), and aneurysm remnants in 4 (10%).</p><p><strong>Conclusions: </strong>The results demonstrate comparable acceptable complication rates and angiographic results of the Phenox HPC, which are similar to other flow diverters. Long-term and comparative studies are needed to evaluate the full potential of these devices.</p>","PeriodicalId":49174,"journal":{"name":"Interventional Neuroradiology","volume":" ","pages":"15910199251318066"},"PeriodicalIF":1.5000,"publicationDate":"2025-02-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11851587/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Interventional Neuroradiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/15910199251318066","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: Phenox flow diverters (p64 and its smaller vessel variant p48) represent an established treatment option for intracranial aneurysms. This study evaluates the safety and efficacy of the new generation of these devices with an additional antithrombotic surface coating (HPC).

Methods: Consecutive patients treated between 2020 and 2023 at three institutions were retrospectively reviewed for aneurysm characteristics, procedural details, complications, and angiographic outcomes.

Results: Sixty-one patients (mean age 56 years) were treated for 61 aneurysms. The mean aneurysm size was 8.3 ± 4.9 mm, 12 (19.7%) were ruptured, 16 (26.2%) were recurrent after previous treatment, 10 (16.4%) were located in the posterior circulation, and 7 (11.5%) had nonsaccular morphology. All procedures were technically successful, with a single device sufficient in 60/61 (98%) cases. Delivery problems included device twisting in one case and incomplete proximal opening in another. Additional angioplasty was performed in 3/61 (4.9%) procedures and additional coiling in 4 (6.6%). There were 3 (4.9%) major events (1 thromboembolic ischemic stroke, 1 fatal intracranial hemorrhage, and 1 delayed aneurysm rupture) and 6 (9.8%) minor strokes. Follow up at a mean of 6 months showed complete occlusion in 33/42 (79%) aneurysms, neck remnants in 5 (12%), and aneurysm remnants in 4 (10%).

Conclusions: The results demonstrate comparable acceptable complication rates and angiographic results of the Phenox HPC, which are similar to other flow diverters. Long-term and comparative studies are needed to evaluate the full potential of these devices.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
Interventional Neuroradiology
Interventional Neuroradiology CLINICAL NEUROLOGY-RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
CiteScore
3.60
自引率
11.80%
发文量
192
审稿时长
6-12 weeks
期刊介绍: Interventional Neuroradiology (INR) is a peer-reviewed clinical practice journal documenting the current state of interventional neuroradiology worldwide. INR publishes original clinical observations, descriptions of new techniques or procedures, case reports, and articles on the ethical and social aspects of related health care. Original research published in INR is related to the practice of interventional neuroradiology...
期刊最新文献
Analysis of endovascular treatment for cerebral vasospasms after subarachnoid hemorrhage in the Japanese Registry of Neuroendovascular Therapy 4. Virtual simulation for flow-diverter selection and sizing in the endovascular treatment of intracranial aneurysms: A systematic review and meta-analysis. Balloon occlusion testing for non-sinus-stenosis venous pulsatile tinnitus: A technical case series. Mechanical thrombectomy for acute ischemic stroke performed without continuous saline flushes and using moderate sedation: The TOOFAST technique. Multicenter study of HPC coated p48 and p64 flow diverters for treatment of intracranial aneurysms under dual antiplatelet therapy.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1