Fracture Resistance of 3D Printed Restorations in Different Thicknesses for Primary Molars.

Nilge Sarimehmetoglu, Huseyin Simsek
{"title":"Fracture Resistance of 3D Printed Restorations in Different Thicknesses for Primary Molars.","authors":"Nilge Sarimehmetoglu, Huseyin Simsek","doi":"10.11607/ijp.9234","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The aim of this study was to evaluate the fracture resistance of primary tooth crowns fabricated at different thicknesses using two different 3D printing technologies: stereolithography (SLA) and digital light processing (DLP).</p><p><strong>Materials and methods: </strong>A typodont primary second molar tooth was scanned. Using the scanned model, three dies and crowns with thicknesses of 0.5 mm, 1.0 mm and 1.5 mm were created digitally. A total of 60 dies were fabricated from Crom-Cobalt (Cr-Co) using a laser sintering device. Ten crowns per thickness were produced using two types of 3D printers: SLA and DLP. The fracture resistance of the crowns was tested after thermal aging (5/55 oC and 30 s dwell time). The data were analyzed with Independent sampleT-test.</p><p><strong>Results: </strong>There was no significant difference in fracture resistance between the manufacturing methods for crowns in all three thickness groups (p > 0.05). The highest average fracture value was observed in crowns with a thickness of 1.5 mm manufactured using SLA 3D printing.</p><p><strong>Conclusion: </strong>Within the limits of this study, the 3D printing manufacturing method did not affect the fracture resistance of 3D printed primary tooth crowns. It was concluded that these crowns have sufficient fracture resistance and can be used as an alternative treatment option for complete crown of primary teeth.</p>","PeriodicalId":94232,"journal":{"name":"The International journal of prosthodontics","volume":"0 0","pages":"1-18"},"PeriodicalIF":0.0000,"publicationDate":"2025-02-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The International journal of prosthodontics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.11607/ijp.9234","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: The aim of this study was to evaluate the fracture resistance of primary tooth crowns fabricated at different thicknesses using two different 3D printing technologies: stereolithography (SLA) and digital light processing (DLP).

Materials and methods: A typodont primary second molar tooth was scanned. Using the scanned model, three dies and crowns with thicknesses of 0.5 mm, 1.0 mm and 1.5 mm were created digitally. A total of 60 dies were fabricated from Crom-Cobalt (Cr-Co) using a laser sintering device. Ten crowns per thickness were produced using two types of 3D printers: SLA and DLP. The fracture resistance of the crowns was tested after thermal aging (5/55 oC and 30 s dwell time). The data were analyzed with Independent sampleT-test.

Results: There was no significant difference in fracture resistance between the manufacturing methods for crowns in all three thickness groups (p > 0.05). The highest average fracture value was observed in crowns with a thickness of 1.5 mm manufactured using SLA 3D printing.

Conclusion: Within the limits of this study, the 3D printing manufacturing method did not affect the fracture resistance of 3D printed primary tooth crowns. It was concluded that these crowns have sufficient fracture resistance and can be used as an alternative treatment option for complete crown of primary teeth.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Clinical Evaluation of Lithium Disilicate Chairside CAD/CAM Crown after 10-years. Fracture Resistance of 3D Printed Restorations in Different Thicknesses for Primary Molars. Neuromuscular Position of the TMJ Condyle in Fully Dentate Volunteers Characteristics and Potential Indications. Pre-Prosthetic Intrusion of Maxillary Molars by Clear Aligners: A Case Report. Accuracy of Intraoral Scanning Versus Analog Impression for Multiple Implant-supported Prostheses in Long Edentulous Spans: A Comparative Clinical Study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1