Microvascular Ultrasonography Vascularity Index as a Rapid and Simplified Assessment Tool for Differentiating Graves' from Destructive Thyroiditis and Managing Thyrotoxicosis.
Han-Sang Baek, Chaiho Jeong, Jeonghoon Ha, Dong-Jun Lim
{"title":"Microvascular Ultrasonography Vascularity Index as a Rapid and Simplified Assessment Tool for Differentiating Graves' from Destructive Thyroiditis and Managing Thyrotoxicosis.","authors":"Han-Sang Baek, Chaiho Jeong, Jeonghoon Ha, Dong-Jun Lim","doi":"10.3803/EnM.2024.2206","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Thyrotoxicosis presents significant diagnostic challenges in distinguishing Graves' disease (GD) from destruction-induced thyrotoxicosis (DT) using ultrasound imaging. We evaluated a new technology, microvascular ultrasonography (MVUS) to effectively differentiate between GD and DT, and observe the MVUS changes during follow-up.</p><p><strong>Methods: </strong>A total of 264 consecutive patients were prospectively enrolled into two cohorts from August 2022 to March 2024 at one tertiary referral hospital: cohort 1 comprised patients initially presenting with thyrotoxicosis (n=185; 98 with GD and 87 with DT). Cohort 2 included patients either with GD considering antithyroid drug discontinuation or with DT in the follow-up phase after treatment (n=77). Ultrasound imaging was conducted using the MVUS technique, and the vascularity index (MVUS-VI) was automatically calculated as the percentage ratio of color pixels to total grayscale pixels within a specified region of interest.</p><p><strong>Results: </strong>Diagnostic accuracy highlighted MVUS-VI as the most accurate diagnostic tool, achieving a sensitivity of 79.6%, specificity of 84.3%, with an area under the curve of 0.856 (95% confidence interval, 0.800 to 0.911). Presence of thyroid peroxidase antibody or thyroglobulin antibody affected MVUS-VI's performance, requiring a higher cut-off value for specificity in this subgroup. Follow-up in cohort 2 (n=77) demonstrated significant normalization in thyroid function and reductions in MVUS-VI from an initial 32.6%±23.4% to 20.8%±13.5% at follow-up (P<0.001).</p><p><strong>Conclusion: </strong>MVUS-VI provides a rapid, non-invasive diagnostic alternative to traditional methods in differentiating GD from DT, thus aiding in the management of patients with thyrotoxicosis.</p>","PeriodicalId":11636,"journal":{"name":"Endocrinology and Metabolism","volume":" ","pages":""},"PeriodicalIF":3.9000,"publicationDate":"2025-02-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Endocrinology and Metabolism","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3803/EnM.2024.2206","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENDOCRINOLOGY & METABOLISM","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Thyrotoxicosis presents significant diagnostic challenges in distinguishing Graves' disease (GD) from destruction-induced thyrotoxicosis (DT) using ultrasound imaging. We evaluated a new technology, microvascular ultrasonography (MVUS) to effectively differentiate between GD and DT, and observe the MVUS changes during follow-up.
Methods: A total of 264 consecutive patients were prospectively enrolled into two cohorts from August 2022 to March 2024 at one tertiary referral hospital: cohort 1 comprised patients initially presenting with thyrotoxicosis (n=185; 98 with GD and 87 with DT). Cohort 2 included patients either with GD considering antithyroid drug discontinuation or with DT in the follow-up phase after treatment (n=77). Ultrasound imaging was conducted using the MVUS technique, and the vascularity index (MVUS-VI) was automatically calculated as the percentage ratio of color pixels to total grayscale pixels within a specified region of interest.
Results: Diagnostic accuracy highlighted MVUS-VI as the most accurate diagnostic tool, achieving a sensitivity of 79.6%, specificity of 84.3%, with an area under the curve of 0.856 (95% confidence interval, 0.800 to 0.911). Presence of thyroid peroxidase antibody or thyroglobulin antibody affected MVUS-VI's performance, requiring a higher cut-off value for specificity in this subgroup. Follow-up in cohort 2 (n=77) demonstrated significant normalization in thyroid function and reductions in MVUS-VI from an initial 32.6%±23.4% to 20.8%±13.5% at follow-up (P<0.001).
Conclusion: MVUS-VI provides a rapid, non-invasive diagnostic alternative to traditional methods in differentiating GD from DT, thus aiding in the management of patients with thyrotoxicosis.
期刊介绍:
The aim of this journal is to set high standards of medical care by providing a forum for discussion for basic, clinical, and translational researchers and clinicians on new findings in the fields of endocrinology and metabolism. Endocrinology and Metabolism reports new findings and developments in all aspects of endocrinology and metabolism. The topics covered by this journal include bone and mineral metabolism, cytokines, developmental endocrinology, diagnostic endocrinology, endocrine research, dyslipidemia, endocrine regulation, genetic endocrinology, growth factors, hormone receptors, hormone action and regulation, management of endocrine diseases, clinical trials, epidemiology, molecular endocrinology, neuroendocrinology, neuropeptides, neurotransmitters, obesity, pediatric endocrinology, reproductive endocrinology, signal transduction, the anatomy and physiology of endocrine organs (i.e., the pituitary, thyroid, parathyroid, and adrenal glands, and the gonads), and endocrine diseases (diabetes, nutrition, osteoporosis, etc.).