Unveiling Software Limitations in the Assessment of the Minimum Sectional Area and Volume in Cleft LIP and Palate Patients.

IF 3.4 3区 生物学 Q1 BIOLOGY Life-Basel Pub Date : 2025-02-04 DOI:10.3390/life15020226
Beethoven Estevao Costa, Renato Yassutaka Faria Yaedú, Maísa Pereira-Silva, André Luis da Silva Fabris, Michele Garcia-Usó, Osvaldo Magro Filho, Simone Soares
{"title":"Unveiling Software Limitations in the Assessment of the Minimum Sectional Area and Volume in Cleft LIP and Palate Patients.","authors":"Beethoven Estevao Costa, Renato Yassutaka Faria Yaedú, Maísa Pereira-Silva, André Luis da Silva Fabris, Michele Garcia-Usó, Osvaldo Magro Filho, Simone Soares","doi":"10.3390/life15020226","DOIUrl":null,"url":null,"abstract":"<p><p>The increasing use of cone beam computed tomography (CBCT) has led to a growing demand for DICOM software that enables the assessment and measurement of craniofacial structures. This study aimed to compare the airway volume and the minimum axial area in patients with cleft lip and palate using five different imaging software programs: Dolphin3D, InVivo Dental, ITK Snap, InVesalius, and NemoFAB. Initially, 100 CBCT scans were selected by an examiner, and their corresponding DICOM files were collected. The oropharyngeal segments were delineated following the manufacturer's guidelines, using two different segmentation techniques: interactive and fixed threshold. The results were analyzed using the Friedman test and Wilcoxon post hoc test, with a 5% significance level for all statistical tests. The findings for both the minimum axial area and total volume revealed that the median values across the software groups were higher than expected, and significant differences were observed when comparing the groups (<i>p</i> < 0.001). All five software programs showed notable differences in their outputs. Specifically, a statistically significant difference in volume was found across all groups, except between InVivo and ITK-Snap. It is recommended that pre- and post-treatment comparisons be performed using the same software for consistency.</p>","PeriodicalId":56144,"journal":{"name":"Life-Basel","volume":"15 2","pages":""},"PeriodicalIF":3.4000,"publicationDate":"2025-02-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11855961/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Life-Basel","FirstCategoryId":"99","ListUrlMain":"https://doi.org/10.3390/life15020226","RegionNum":3,"RegionCategory":"生物学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"BIOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

The increasing use of cone beam computed tomography (CBCT) has led to a growing demand for DICOM software that enables the assessment and measurement of craniofacial structures. This study aimed to compare the airway volume and the minimum axial area in patients with cleft lip and palate using five different imaging software programs: Dolphin3D, InVivo Dental, ITK Snap, InVesalius, and NemoFAB. Initially, 100 CBCT scans were selected by an examiner, and their corresponding DICOM files were collected. The oropharyngeal segments were delineated following the manufacturer's guidelines, using two different segmentation techniques: interactive and fixed threshold. The results were analyzed using the Friedman test and Wilcoxon post hoc test, with a 5% significance level for all statistical tests. The findings for both the minimum axial area and total volume revealed that the median values across the software groups were higher than expected, and significant differences were observed when comparing the groups (p < 0.001). All five software programs showed notable differences in their outputs. Specifically, a statistically significant difference in volume was found across all groups, except between InVivo and ITK-Snap. It is recommended that pre- and post-treatment comparisons be performed using the same software for consistency.

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
揭示软件在评估唇腭裂患者最小截面积和体积方面的局限性。
锥形束计算机断层扫描(CBCT)的使用越来越多,导致对DICOM软件的需求不断增长,DICOM软件可以评估和测量颅面结构。本研究旨在利用Dolphin3D、InVivo Dental、ITK Snap、InVesalius和NemoFAB五种不同的成像软件,比较唇腭裂患者气道体积和最小轴向面积。最初,由审查员选择100个CBCT扫描,并收集相应的DICOM文件。口咽段是按照制造商的指导方针划定的,使用两种不同的分割技术:交互式和固定阈值。使用Friedman检验和Wilcoxon事后检验对结果进行分析,所有统计检验的显著性水平为5%。最小轴向面积和总体积的结果显示,软件组的中位数高于预期,并且在比较组时观察到显着差异(p < 0.001)。所有五个软件程序的输出结果都有显著差异。具体来说,除了InVivo和ITK-Snap之间,所有组之间的体积差异都有统计学意义。建议使用相同的软件进行治疗前和治疗后的比较,以保持一致性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Life-Basel
Life-Basel Biochemistry, Genetics and Molecular Biology-General Biochemistry,Genetics and Molecular Biology
CiteScore
4.30
自引率
6.20%
发文量
1798
审稿时长
11 weeks
期刊介绍: Life (ISSN 2075-1729) is an international, peer-reviewed open access journal of scientific studies related to fundamental themes in Life Sciences, especially those concerned with the origins of life and evolution of biosystems. Our aim is to encourage scientists to publish their experimental and theoretical results in as much detail as possible. There is no restriction on the length of the papers.
期刊最新文献
RETRACTED: Lee et al. Protective Effects of Oenothera biennis Against Hydrogen Peroxide-Induced Oxidative Stress and Cell Death in Skin Keratinocytes. Life 2020, 10, 255. Integrating Wearable Sensors and Clinical Tools for Assessing Pelvic Gait Symmetry During ACL Recovery. Dynamics and Predictive Values of Urinary Podocyte Biomarkers Following SGLT2 Inhibition in CKD. Integrative Pharmacological and Computational Analysis of Abelmoschus esculentus Phytochemicals: Enzyme Inhibition, Molecular Docking, and Dynamics Simulation Against Key Antidiabetic Targets. Eccentric Hamstring Strength and Interlimb Asymmetry in Professional Football Players: A NordBord-Based Longitudinal Analysis of Two Professional Teams.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1