Patient-specific titanium-reinforced calcium-phosphate (CaP: Ti) implants for revision cranioplasty

IF 1.9 Q3 CLINICAL NEUROLOGY Brain & spine Pub Date : 2025-01-01 DOI:10.1016/j.bas.2025.104213
Paul Vincent Naser , Friederike Zacharias , Henrik Giese , Sandro M. Krieg , Andreas W. Unterberg , Alexander Younsi
{"title":"Patient-specific titanium-reinforced calcium-phosphate (CaP: Ti) implants for revision cranioplasty","authors":"Paul Vincent Naser ,&nbsp;Friederike Zacharias ,&nbsp;Henrik Giese ,&nbsp;Sandro M. Krieg ,&nbsp;Andreas W. Unterberg ,&nbsp;Alexander Younsi","doi":"10.1016/j.bas.2025.104213","DOIUrl":null,"url":null,"abstract":"<div><h3>Introduction</h3><div>Cranioplasty is a common neurosurgical procedure, but infections can complicate it, necessitating revision surgery. Alloplastic patient-specific implants (PSI) are increasingly utilized, and different materials are available. This study evaluates the role of titanium-reinforced calcium-phosphate (CaP:Ti) implants in revision cranioplasty.</div></div><div><h3>Research question</h3><div>Assessing the efficacy and safety of CaP:Ti PSI in patients requiring revision cranioplasty following complications with previously failed cranioplasty attempts.</div></div><div><h3>Material and methods</h3><div>Retrospective analysis of 15 patients who underwent CaP:Ti PSI implantation for revision cranioplasty between 2016 and 2022 at a single neurosurgical department. Data on demographics, perioperative details, and outcomes were collected and assessed. Differences in distribution were assessed using Fisher's exact test, and groups were numerically compared using student's t-test. A p-value &lt;0.05 was considered statistically significant.</div></div><div><h3>Results</h3><div>In most patients, CP failure occurred early (38 days) following elective craniotomy for tumor and vascular procedures. The first revision cranioplasty was conducted in 12 cases using CaP:Ti PSI in 8 cases successfully requiring no further revision. Three cases implanted with other alloplastic materials required revision and received CaP:Ti PSI in the second (n = 2) or third (n = 1) CP attempt. The overall success rate for CaP:Ti PSI was 73.3% over more than two years of follow-up. success rate in revision cranioplasty. Surgical site complications, predominantly infections, were the main cause of CP failure. The average interval between implant removal and re-cranioplasty was 300 days. Prehabilitation using skin expanders and postoperative antibiotic use were strategies successfully utilized in this cohort.</div></div><div><h3>Discussion and conclusion</h3><div>Our findings suggest that CaP:Ti PSI implants hold promise in salvaging complicated cranioplasty in most cases despite challenges such as infection and implant failure. The use of techniques like skin expanders may contribute to better outcomes. However, further research is crucial to establish optimal timing and patient selection guidelines in revision cranioplasty using CaP:Ti implants, which could significantly impact future neurosurgical practices.</div></div>","PeriodicalId":72443,"journal":{"name":"Brain & spine","volume":"5 ","pages":"Article 104213"},"PeriodicalIF":1.9000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Brain & spine","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2772529425000323","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction

Cranioplasty is a common neurosurgical procedure, but infections can complicate it, necessitating revision surgery. Alloplastic patient-specific implants (PSI) are increasingly utilized, and different materials are available. This study evaluates the role of titanium-reinforced calcium-phosphate (CaP:Ti) implants in revision cranioplasty.

Research question

Assessing the efficacy and safety of CaP:Ti PSI in patients requiring revision cranioplasty following complications with previously failed cranioplasty attempts.

Material and methods

Retrospective analysis of 15 patients who underwent CaP:Ti PSI implantation for revision cranioplasty between 2016 and 2022 at a single neurosurgical department. Data on demographics, perioperative details, and outcomes were collected and assessed. Differences in distribution were assessed using Fisher's exact test, and groups were numerically compared using student's t-test. A p-value <0.05 was considered statistically significant.

Results

In most patients, CP failure occurred early (38 days) following elective craniotomy for tumor and vascular procedures. The first revision cranioplasty was conducted in 12 cases using CaP:Ti PSI in 8 cases successfully requiring no further revision. Three cases implanted with other alloplastic materials required revision and received CaP:Ti PSI in the second (n = 2) or third (n = 1) CP attempt. The overall success rate for CaP:Ti PSI was 73.3% over more than two years of follow-up. success rate in revision cranioplasty. Surgical site complications, predominantly infections, were the main cause of CP failure. The average interval between implant removal and re-cranioplasty was 300 days. Prehabilitation using skin expanders and postoperative antibiotic use were strategies successfully utilized in this cohort.

Discussion and conclusion

Our findings suggest that CaP:Ti PSI implants hold promise in salvaging complicated cranioplasty in most cases despite challenges such as infection and implant failure. The use of techniques like skin expanders may contribute to better outcomes. However, further research is crucial to establish optimal timing and patient selection guidelines in revision cranioplasty using CaP:Ti implants, which could significantly impact future neurosurgical practices.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
Brain & spine
Brain & spine Surgery
CiteScore
1.10
自引率
0.00%
发文量
0
审稿时长
71 days
期刊最新文献
The identification of low-pathogenic bacteria on removed spinal implants and implications for antimicrobial prophylaxis Kinematic limitations during stair ascent and descent in patients with adult spinal deformity Letter to the editor “Treatment-limiting decisions in patients with severe traumatic brain injury in the Netherlands” Lumbar disc space height in relation to neural foraminal dimensions and patient characteristics: A morphometric analysis from L1-S1 using computed tomography Advancements and emerging insights in thoracolumbar spine trauma
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1