Mehmet Karagülle, Fatma Zeynep Arslan, Burcu Ozcan, Arzu Algun Gedik
{"title":"A Comparison of Different Transfer Techniques in Evaluating Specimen Adequacy in FNAB: An Unexplored Topic.","authors":"Mehmet Karagülle, Fatma Zeynep Arslan, Burcu Ozcan, Arzu Algun Gedik","doi":"10.1002/dc.25458","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>This study compared two conventional smear methods during FNAB: The method where the green part of the syringe is touched to the slide (Technique 1) and the method where the contents are rapidly sprayed (Technique 2). We investigated differences in specimen adequacy, diagnostic outcomes, and variations among pathological subgroups.</p><p><strong>Methods: </strong>FNAB was performed on 128 lesions from 119 patients, and the samples were classified according to the Bethesda System. The two transfer techniques were compared in terms of cell count and diagnostic results.</p><p><strong>Results: </strong>Of the 128 lesions, 93 were diagnosed as adenomatous nodules. No significant difference was found in the nondiagnostic result rates between the methods. The p-value was found to be 0.65. The average cell count in Technique 1 was 1.95 (min: 0, max: 3+, SD: 1.03), while in Technique 2 it was 1.91 (min: 0, max: 3+, SD: 1.07). Although Technique 1 resulted in a slightly higher positive cell detection, the two techniques were not superior to each other in terms of cell count. The p-value was found to be 0.87. When both techniques were used together, more diagnoses could be made in more patients compared to when each technique was used separately. However, statistically, the combined use of both techniques was not superior to Technique 1 (p = 0.16) or Technique 2 (p = 0.083).</p><p><strong>Conclusion: </strong>Both techniques showed similar nondiagnostic rates. Technique 1 resulted in a slight increase in the average positive cell count, whereas Technique 2 may be preferred due to its simplicity and safety. It was also found that neither technique provided a clear superiority over the other, and using both techniques together was not superior to either Technique 1 or Technique 2. In determining standard FNAB procedures and improving diagnostic accuracy, factors such as nodule characteristics and needle caliber, along with smear techniques, should also be considered. Larger-scale studies are necessary to validate these findings and improve FNAB practices.</p>","PeriodicalId":11349,"journal":{"name":"Diagnostic Cytopathology","volume":" ","pages":""},"PeriodicalIF":1.0000,"publicationDate":"2025-02-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Diagnostic Cytopathology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1002/dc.25458","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Introduction: This study compared two conventional smear methods during FNAB: The method where the green part of the syringe is touched to the slide (Technique 1) and the method where the contents are rapidly sprayed (Technique 2). We investigated differences in specimen adequacy, diagnostic outcomes, and variations among pathological subgroups.
Methods: FNAB was performed on 128 lesions from 119 patients, and the samples were classified according to the Bethesda System. The two transfer techniques were compared in terms of cell count and diagnostic results.
Results: Of the 128 lesions, 93 were diagnosed as adenomatous nodules. No significant difference was found in the nondiagnostic result rates between the methods. The p-value was found to be 0.65. The average cell count in Technique 1 was 1.95 (min: 0, max: 3+, SD: 1.03), while in Technique 2 it was 1.91 (min: 0, max: 3+, SD: 1.07). Although Technique 1 resulted in a slightly higher positive cell detection, the two techniques were not superior to each other in terms of cell count. The p-value was found to be 0.87. When both techniques were used together, more diagnoses could be made in more patients compared to when each technique was used separately. However, statistically, the combined use of both techniques was not superior to Technique 1 (p = 0.16) or Technique 2 (p = 0.083).
Conclusion: Both techniques showed similar nondiagnostic rates. Technique 1 resulted in a slight increase in the average positive cell count, whereas Technique 2 may be preferred due to its simplicity and safety. It was also found that neither technique provided a clear superiority over the other, and using both techniques together was not superior to either Technique 1 or Technique 2. In determining standard FNAB procedures and improving diagnostic accuracy, factors such as nodule characteristics and needle caliber, along with smear techniques, should also be considered. Larger-scale studies are necessary to validate these findings and improve FNAB practices.
期刊介绍:
Diagnostic Cytopathology is intended to provide a forum for the exchange of information in the field of cytopathology, with special emphasis on the practical, clinical aspects of the discipline. The editors invite original scientific articles, as well as special review articles, feature articles, and letters to the editor, from laboratory professionals engaged in the practice of cytopathology. Manuscripts are accepted for publication on the basis of scientific merit, practical significance, and suitability for publication in a journal dedicated to this discipline. Original articles can be considered only with the understanding that they have never been published before and that they have not been submitted for simultaneous review to another publication.