[Effect of Temperature Cycle Preservation on Platelet Aggregation Rate and Routine Parameters].

Ju-Ling Liang, Zhi-Hao Deng, Chuang-Jin Zhuo, Lu Huang, Jing Xu, Wei-Jian Wu
{"title":"[Effect of Temperature Cycle Preservation on Platelet Aggregation Rate and Routine Parameters].","authors":"Ju-Ling Liang, Zhi-Hao Deng, Chuang-Jin Zhuo, Lu Huang, Jing Xu, Wei-Jian Wu","doi":"10.19746/j.cnki.issn.1009-2137.2025.01.035","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To compare and analyze the changes of aggregation rate and routine parameters of platelets stored in temperature cycle, cold storage at 4 ℃ and oscillating storage at 22 ℃, so as to provide more experimental data for platelet preservation methods.</p><p><strong>Methods: </strong>Blood samples were collected at 5 time points on the 1<sup>st</sup>, 2<sup>nd</sup>, 3<sup>rd</sup>, 4<sup>th</sup> and 6<sup>th</sup> day after platelet cycling preservation at temperature, cold storage at 4 ℃, and oscillating storage at 22 ℃. Platelet maximum aggregation rate (MAR) and routine parameters including platelet count (PLT), mean platelet volume (MPV), platelet distribution width (PDW) and platelet-larger cell ratio (P-LCR) were detected.</p><p><strong>Results: </strong>The platelet MAR of three groups showed a significant decrease trend with the preservation time, the fastest decrease was in the 22 ℃ group, the slowest was in the 4 ℃ group, and the temperature cycle group was between the two groups. On the 3<sup>rd</sup> day of preservation, the platelet MAR in 4 ℃ group was still in the normal range (MAR>60%), while in temperature cycle group was about 50%, and in 22 ℃ group was the lowest. On the 4<sup>th</sup> day of preservation, platelet MAR in all the three groups was lower than 50%, and that in temperature cycle group was significantly lower than in 4 ℃ group but higher than in 22 ℃ group (both <i>P</i> < 0.05). On the 6<sup>th</sup> day of preservation, platelet MAR in the temperature cycle group was significantly lower than that in the 4 ℃ group ( <i>P</i> <0.05), but there was no statistically significant difference compared to 22 ℃ group (<i>P</i> >0.05). PLT values in the three groups were all significantly decreased with the preservation time extension, and were significantly lower than those in the early stage of preservation within 6 days (all <i>P</i> < 0.05). PDW in temperature cycle group had no significant change within 6 days of preservation, but MPV and P-LCR were significantly increased. MPV, PDW and P-LCR all decreased significantly in 4 ℃ group within 6 days of preservation but increased in 22 ℃ group. Under the same storage days, PLT value of temperature cycle group had no significant difference with that of 4 ℃ group and 22 ℃ group, while MPV, PDW and P-LCR values were significantly higher than 4 ℃ group but lower than 22 ℃ group (all <i>P</i> < 0.05).</p><p><strong>Conclusion: </strong>The aggregation function and routine parameters changes of temperature circulating preserved platelets are between 4 and 22 ℃.</p>","PeriodicalId":35777,"journal":{"name":"中国实验血液学杂志","volume":"33 1","pages":"236-240"},"PeriodicalIF":0.0000,"publicationDate":"2025-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"中国实验血液学杂志","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.19746/j.cnki.issn.1009-2137.2025.01.035","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: To compare and analyze the changes of aggregation rate and routine parameters of platelets stored in temperature cycle, cold storage at 4 ℃ and oscillating storage at 22 ℃, so as to provide more experimental data for platelet preservation methods.

Methods: Blood samples were collected at 5 time points on the 1st, 2nd, 3rd, 4th and 6th day after platelet cycling preservation at temperature, cold storage at 4 ℃, and oscillating storage at 22 ℃. Platelet maximum aggregation rate (MAR) and routine parameters including platelet count (PLT), mean platelet volume (MPV), platelet distribution width (PDW) and platelet-larger cell ratio (P-LCR) were detected.

Results: The platelet MAR of three groups showed a significant decrease trend with the preservation time, the fastest decrease was in the 22 ℃ group, the slowest was in the 4 ℃ group, and the temperature cycle group was between the two groups. On the 3rd day of preservation, the platelet MAR in 4 ℃ group was still in the normal range (MAR>60%), while in temperature cycle group was about 50%, and in 22 ℃ group was the lowest. On the 4th day of preservation, platelet MAR in all the three groups was lower than 50%, and that in temperature cycle group was significantly lower than in 4 ℃ group but higher than in 22 ℃ group (both P < 0.05). On the 6th day of preservation, platelet MAR in the temperature cycle group was significantly lower than that in the 4 ℃ group ( P <0.05), but there was no statistically significant difference compared to 22 ℃ group (P >0.05). PLT values in the three groups were all significantly decreased with the preservation time extension, and were significantly lower than those in the early stage of preservation within 6 days (all P < 0.05). PDW in temperature cycle group had no significant change within 6 days of preservation, but MPV and P-LCR were significantly increased. MPV, PDW and P-LCR all decreased significantly in 4 ℃ group within 6 days of preservation but increased in 22 ℃ group. Under the same storage days, PLT value of temperature cycle group had no significant difference with that of 4 ℃ group and 22 ℃ group, while MPV, PDW and P-LCR values were significantly higher than 4 ℃ group but lower than 22 ℃ group (all P < 0.05).

Conclusion: The aggregation function and routine parameters changes of temperature circulating preserved platelets are between 4 and 22 ℃.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
[温度循环保存对血小板聚集率和常规参数的影响]
目的:比较分析温度循环、4℃冷藏和22℃振荡贮藏血小板聚集率及常规参数的变化,为血小板保存方法提供更多实验数据。方法:分别于血小板低温循环保存、4℃冷藏、22℃振荡保存后第1、2、3、4、6天的5个时间点采集血样。检测血小板最大聚集率(MAR)及血小板计数(PLT)、平均血小板体积(MPV)、血小板分布宽度(PDW)、血小板-大细胞比(P-LCR)等常规参数。结果:三组血小板MAR随保存时间的延长均呈显著下降趋势,22℃组下降最快,4℃组下降最慢,温度循环组介于两组之间。保存第3天,4℃组血小板MAR仍在正常范围内(MAR>60%),温度循环组约为50%,22℃组最低。保存第4天,3组血小板MAR均低于50%,温度循环组显著低于4℃组,但高于22℃组(P < 0.05)。保存第6天,温度循环组血小板MAR显著低于4℃组(P < 0.05)。随着保存时间的延长,3组的PLT值均显著降低,且在6 d内显著低于保存前期(均P < 0.05)。温度循环组在保存6 d内PDW无显著变化,但MPV和P-LCR显著升高。4℃组MPV、PDW和P-LCR在保存6 d内均显著降低,22℃组MPV、PDW和P-LCR均升高。相同贮藏天数下,温度循环组的PLT值与4℃组和22℃组差异不显著,MPV、PDW和P- lcr值显著高于4℃组,但低于22℃组(均P < 0.05)。结论:低温循环保存血小板的聚集功能和常规参数变化在4 ~ 22℃之间。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
中国实验血液学杂志
中国实验血液学杂志 Medicine-Medicine (all)
CiteScore
0.40
自引率
0.00%
发文量
7331
期刊介绍:
期刊最新文献
[NK Cell Immunotherapy for Acute Myeloid Leukemia: Recent Advances and the Immunomodulatory Role of Traditional Chinese Medicine--Review]. [Observation of the Therapeutic Effect of Venetoclax Combined with HEA Regimen on Acute Myeloid Leukemia Patients with KMT2A Gene Rearrangement]. [Prediction of High-Risk Factors for Survival Outcomes in Children Undergoing Massive Intraoperative Blood Transfusion]. [Prognostic Value of Prognostic Nutritional Index and Lymphocyte-to-Monocyte Ratio in Patients with Follicular Lymphoma]. [Research Progress of Megakaryocyte Morphology in the Prognosis of Primary Myelofibrosis--Review].
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1