Brian C. Jacobson, Joseph C. Anderson, Carol A. Burke, Jason A. Dominitz, Seth A. Gross, Folasade P. May, Swati G. Patel, Aasma Shaukat, Douglas J. Robertson
{"title":"Optimizing Bowel Preparation Quality for Colonoscopy: Consensus Recommendations by the US Multi-Society Task Force on Colorectal Cancer","authors":"Brian C. Jacobson, Joseph C. Anderson, Carol A. Burke, Jason A. Dominitz, Seth A. Gross, Folasade P. May, Swati G. Patel, Aasma Shaukat, Douglas J. Robertson","doi":"10.1053/j.gastro.2025.02.002","DOIUrl":null,"url":null,"abstract":"This document is an update to the 2014 recommendations for optimizing the adequacy of bowel cleansing for colonoscopy from the US Multi-Society Task Force on Colorectal Cancer, which represents the American College of Gastroenterology and the American Society for Gastrointestinal Endoscopy. The US Multi-Society Task Force developed consensus statements and key clinical concepts addressing important aspects of bowel preparation for colonoscopy. The majority of consensus statements focus on individuals at average risk for inadequate bowel preparation. However, statements addressing individuals at risk for inadequate bowel preparation quality are also provided. The quality of a bowel preparation is defined as adequate when standard screening or surveillance intervals can be assigned based on the findings of the colonoscopy. We recommend the use of a split-dose bowel preparation regimen and suggest that a 2 L regimen may be sufficient. A same-day regimen is recommended as an acceptable alternative for individuals undergoing afternoon colonoscopy, but we suggest that a same-day regimen is an inferior alternative for individuals undergoing morning colonoscopy. We recommend limiting dietary restrictions to the day before a colonoscopy, relying on either clear liquids or low-fiber/low-residue diets for the early and midday meals. We suggest the adjunctive use of oral simethicone for bowel preparation before colonoscopy. Routine tracking of the rate of adequate bowel preparations at the level of individual endoscopists and at the level of the endoscopy unit is also recommended, with a target of >90% for both rates.","PeriodicalId":12590,"journal":{"name":"Gastroenterology","volume":"29 1","pages":""},"PeriodicalIF":25.7000,"publicationDate":"2025-03-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Gastroenterology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1053/j.gastro.2025.02.002","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"GASTROENTEROLOGY & HEPATOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
This document is an update to the 2014 recommendations for optimizing the adequacy of bowel cleansing for colonoscopy from the US Multi-Society Task Force on Colorectal Cancer, which represents the American College of Gastroenterology and the American Society for Gastrointestinal Endoscopy. The US Multi-Society Task Force developed consensus statements and key clinical concepts addressing important aspects of bowel preparation for colonoscopy. The majority of consensus statements focus on individuals at average risk for inadequate bowel preparation. However, statements addressing individuals at risk for inadequate bowel preparation quality are also provided. The quality of a bowel preparation is defined as adequate when standard screening or surveillance intervals can be assigned based on the findings of the colonoscopy. We recommend the use of a split-dose bowel preparation regimen and suggest that a 2 L regimen may be sufficient. A same-day regimen is recommended as an acceptable alternative for individuals undergoing afternoon colonoscopy, but we suggest that a same-day regimen is an inferior alternative for individuals undergoing morning colonoscopy. We recommend limiting dietary restrictions to the day before a colonoscopy, relying on either clear liquids or low-fiber/low-residue diets for the early and midday meals. We suggest the adjunctive use of oral simethicone for bowel preparation before colonoscopy. Routine tracking of the rate of adequate bowel preparations at the level of individual endoscopists and at the level of the endoscopy unit is also recommended, with a target of >90% for both rates.
期刊介绍:
Gastroenterology is the most prominent journal in the field of gastrointestinal disease. It is the flagship journal of the American Gastroenterological Association and delivers authoritative coverage of clinical, translational, and basic studies of all aspects of the digestive system, including the liver and pancreas, as well as nutrition.
Some regular features of Gastroenterology include original research studies by leading authorities, comprehensive reviews and perspectives on important topics in adult and pediatric gastroenterology and hepatology. The journal also includes features such as editorials, correspondence, and commentaries, as well as special sections like "Mentoring, Education and Training Corner," "Diversity, Equity and Inclusion in GI," "Gastro Digest," "Gastro Curbside Consult," and "Gastro Grand Rounds."
Gastroenterology also provides digital media materials such as videos and "GI Rapid Reel" animations. It is abstracted and indexed in various databases including Scopus, Biological Abstracts, Current Contents, Embase, Nutrition Abstracts, Chemical Abstracts, Current Awareness in Biological Sciences, PubMed/Medline, and the Science Citation Index.