{"title":"Tibial morphological difference between metal augmentation and actual tibia for revision total knee arthroplasty.","authors":"Yushi Sakamoto, Shinichiro Nakamura, Yugo Morita, Shinichi Kuriyama, Kohei Nishitani, Sayako Sakai, Yuki Shinya, Shuichi Matsuda","doi":"10.1186/s43019-025-00262-9","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>An overhang of the tibial component can cause irritation of the surrounding soft tissues, whereas an underhang is associated with risks of tibial bone resorption. It is not well known whether the tapering angle of currently available blocks at medial, lateral, anterior, and posterior sides matches the actual shape of the proximal tibia. The purpose of this study was to analyze the bony contour of the proximal tibia and measure the tapering angle to examine whether the angle of currently available metal augmentation blocks matches the actual tibia.</p><p><strong>Methods: </strong>Computed tomography of the lower extremities was performed on 100 consecutive knees, and three-dimensional images of the tibia were reconstructed. The primary resection level was determined on the basis of a plane 10 mm below the center of the lateral tibial plateau. The assumed levels were set to 5, 10, 15, and 20 mm below the primary resection level. All points that were 5, 10, 15, or 20 mm below were projected onto the primary resection surface, and the reduction value from the primary level to each level was measured. The tapering angle was calculated on the basis of the reduction value from the primary level to each resection surface at eight areas and compared with the angle of currently available metal augmentation acquired from the company. The distances of mismatch between the metal augmentation and the bone surface were calculated.</p><p><strong>Results: </strong>The tapering angle on the medial and lateral sides increased with the more distal resection level, which was up to 30° at the 20 mm level. The tapering angle on the posterior side also increased with the more distal resection level, which was approximately 40° at the 20 mm level. The tapering angle of the current implant was smaller than that of the original tibial morphology. The distances of mismatch varied between implants in which the maximum distance was up to 11.3 mm in the 15 mm augmentation.</p><p><strong>Conclusions: </strong>The design of current metal augmentation differs from the morphology of the proximal tibia. Surgeons should pay attention to the size mismatch between the femoral and tibial components during revision total knee arthroplasty (TKA).</p>","PeriodicalId":36317,"journal":{"name":"Knee Surgery and Related Research","volume":"37 1","pages":"10"},"PeriodicalIF":0.0000,"publicationDate":"2025-03-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11874112/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Knee Surgery and Related Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1186/s43019-025-00262-9","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Background: An overhang of the tibial component can cause irritation of the surrounding soft tissues, whereas an underhang is associated with risks of tibial bone resorption. It is not well known whether the tapering angle of currently available blocks at medial, lateral, anterior, and posterior sides matches the actual shape of the proximal tibia. The purpose of this study was to analyze the bony contour of the proximal tibia and measure the tapering angle to examine whether the angle of currently available metal augmentation blocks matches the actual tibia.

Methods: Computed tomography of the lower extremities was performed on 100 consecutive knees, and three-dimensional images of the tibia were reconstructed. The primary resection level was determined on the basis of a plane 10 mm below the center of the lateral tibial plateau. The assumed levels were set to 5, 10, 15, and 20 mm below the primary resection level. All points that were 5, 10, 15, or 20 mm below were projected onto the primary resection surface, and the reduction value from the primary level to each level was measured. The tapering angle was calculated on the basis of the reduction value from the primary level to each resection surface at eight areas and compared with the angle of currently available metal augmentation acquired from the company. The distances of mismatch between the metal augmentation and the bone surface were calculated.

Results: The tapering angle on the medial and lateral sides increased with the more distal resection level, which was up to 30° at the 20 mm level. The tapering angle on the posterior side also increased with the more distal resection level, which was approximately 40° at the 20 mm level. The tapering angle of the current implant was smaller than that of the original tibial morphology. The distances of mismatch varied between implants in which the maximum distance was up to 11.3 mm in the 15 mm augmentation.

Conclusions: The design of current metal augmentation differs from the morphology of the proximal tibia. Surgeons should pay attention to the size mismatch between the femoral and tibial components during revision total knee arthroplasty (TKA).

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
6.50
自引率
0.00%
发文量
42
审稿时长
19 weeks
期刊最新文献
Do knee alignment patterns differ between Middle Eastern and East Asian populations? A propensity-matched analysis using artificial intelligence. Tibial morphological difference between metal augmentation and actual tibia for revision total knee arthroplasty. McMurray's test is influenced by perimeniscal synovitis in degenerative meniscus tears. Caliper verification and gap measurements of kinematic alignment total knee arthroplasty utilizing an imageless, accelerometer-based navigation system. Relationship between muscle activation and sagittal knee joint biomechanics in patients with patellofemoral pain syndrome: a cross-sectional study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1