Posterior tibial slope after total knee arthroplasty is not reproducible or consistent

IF 1.6 4区 医学 Q3 ORTHOPEDICS Knee Pub Date : 2025-03-04 DOI:10.1016/j.knee.2025.01.006
Ekin Barış Demir, Fatih Barça, Mert Uçak, Halis Atıl Atilla, Mutlu Akdoğan, Yalım Ateş
{"title":"Posterior tibial slope after total knee arthroplasty is not reproducible or consistent","authors":"Ekin Barış Demir,&nbsp;Fatih Barça,&nbsp;Mert Uçak,&nbsp;Halis Atıl Atilla,&nbsp;Mutlu Akdoğan,&nbsp;Yalım Ateş","doi":"10.1016/j.knee.2025.01.006","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><div>Our aim was to compare posterior tibial slope (PTS) values, distribution, deviation from manufacturer’s recommended value and restoration of this value in total knee arthroplasty (TKA) with tibial component placement using intramedullary (IM) and extramedullary (EM) methods, and to analyze factors affecting these values.</div></div><div><h3>Methods</h3><div>A total of 151 knees operated with Zimmer-Biomet NexGen® LPS Fixed Bearing Knee TKA between 2022 and 2024 were retrospectively investigated. Knees were grouped by method of tibial component placement (IM or EM). Pre-operative descriptive data, postoperative PTS, scatteredness of PTS, difference between pre-operative and postoperative PTS, deviation from 7° which was claimed by the manufacturer and rate of outliers were compared between groups. Factors that might affect postoperative PTS in the EM group were analyzed.</div></div><div><h3>Results</h3><div>Ninety-five knees (62.9%) in the EM group and 56 knees (37.1%) in the IM group were analyzed. Mean PTS decreased from 8.8 ± 3.5° to 6.7 ± 2.7° (<em>P</em> &lt; 0.001) in the EM group, and from 10 ± 4.1° to 4.9 ± 2.6° (<em>P</em> &lt; 0.001) in the IM group. Postoperative PTS was significantly lower in the IM group (<em>P</em> &lt; 0.001<u>)</u>. Mean deviation from 7° claimed by the manufacturer was 2.4 ± 1.4° for the EM group and 2.8 ± 1.8° for the IM group (<em>P</em> = 0.14). In 15 of 151 patients (9.9%), postoperative PTS was above 10°. Linear regression analysis revealed a moderate effect of pre-operative PTS and weight in the EM group.</div></div><div><h3>Conclusions</h3><div>Although not statistically significant, the EM method is closer to the manufacturer’s recommendation for sagittal alignment. However, both groups had a wide range of PTS and a large number of outliers. Both methods are not reliable in terms of PTS reproducibility and consistency.</div></div>","PeriodicalId":56110,"journal":{"name":"Knee","volume":"54 ","pages":"Pages 136-145"},"PeriodicalIF":1.6000,"publicationDate":"2025-03-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Knee","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0968016025000067","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

Background

Our aim was to compare posterior tibial slope (PTS) values, distribution, deviation from manufacturer’s recommended value and restoration of this value in total knee arthroplasty (TKA) with tibial component placement using intramedullary (IM) and extramedullary (EM) methods, and to analyze factors affecting these values.

Methods

A total of 151 knees operated with Zimmer-Biomet NexGen® LPS Fixed Bearing Knee TKA between 2022 and 2024 were retrospectively investigated. Knees were grouped by method of tibial component placement (IM or EM). Pre-operative descriptive data, postoperative PTS, scatteredness of PTS, difference between pre-operative and postoperative PTS, deviation from 7° which was claimed by the manufacturer and rate of outliers were compared between groups. Factors that might affect postoperative PTS in the EM group were analyzed.

Results

Ninety-five knees (62.9%) in the EM group and 56 knees (37.1%) in the IM group were analyzed. Mean PTS decreased from 8.8 ± 3.5° to 6.7 ± 2.7° (P < 0.001) in the EM group, and from 10 ± 4.1° to 4.9 ± 2.6° (P < 0.001) in the IM group. Postoperative PTS was significantly lower in the IM group (P < 0.001). Mean deviation from 7° claimed by the manufacturer was 2.4 ± 1.4° for the EM group and 2.8 ± 1.8° for the IM group (P = 0.14). In 15 of 151 patients (9.9%), postoperative PTS was above 10°. Linear regression analysis revealed a moderate effect of pre-operative PTS and weight in the EM group.

Conclusions

Although not statistically significant, the EM method is closer to the manufacturer’s recommendation for sagittal alignment. However, both groups had a wide range of PTS and a large number of outliers. Both methods are not reliable in terms of PTS reproducibility and consistency.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
Knee
Knee 医学-外科
CiteScore
3.80
自引率
5.30%
发文量
171
审稿时长
6 months
期刊介绍: The Knee is an international journal publishing studies on the clinical treatment and fundamental biomechanical characteristics of this joint. The aim of the journal is to provide a vehicle relevant to surgeons, biomedical engineers, imaging specialists, materials scientists, rehabilitation personnel and all those with an interest in the knee. The topics covered include, but are not limited to: • Anatomy, physiology, morphology and biochemistry; • Biomechanical studies; • Advances in the development of prosthetic, orthotic and augmentation devices; • Imaging and diagnostic techniques; • Pathology; • Trauma; • Surgery; • Rehabilitation.
期刊最新文献
Is leukocyte scintigraphy recommended in periprosthetic knee infection diagnosis? A retrospective study of 92 total knee arthroplasties Posterior tibial slope after total knee arthroplasty is not reproducible or consistent Comparison of predictive models for knee pain and analysis of individual and physical activity variables using interpretable machine learning Periarticular injection versus placebo in total knee arthroplasty with intrathecal morphine An AI-based system for fully automated knee alignment assessment in standard AP knee radiographs
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1