Validation of the PlusOptix S12C for detecting amblyopia risk factors in a tertiary care young paediatric population.

IF 2.8 3区 医学 Q1 OPHTHALMOLOGY Ophthalmic and Physiological Optics Pub Date : 2025-03-06 DOI:10.1111/opo.13484
Hadas Ben-Eli, Alon Avrahami, Aviya Benyamin, Edna Granit, Hadas Mechoulam, Irene Anteby
{"title":"Validation of the PlusOptix S12C for detecting amblyopia risk factors in a tertiary care young paediatric population.","authors":"Hadas Ben-Eli, Alon Avrahami, Aviya Benyamin, Edna Granit, Hadas Mechoulam, Irene Anteby","doi":"10.1111/opo.13484","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate the sensitivity and specificity of the PlusOptix S12C device in detecting amblyopia risk factors (ARFs) in children aged 2-7 years, in accordance with the 2020 Israeli Ministry of Health (MOH) directives and the 2021 American Association for Pediatric Ophthalmology and Strabismus (AAPOS) guidelines.</p><p><strong>Methods: </strong>A cross-sectional, observational study was conducted at a tertiary care hospital. Children presenting for vision testing were screened using the PlusOptix S12C device, and results were compared with the gold standard cycloplegic refraction and cover test. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were calculated for the overall population and subpopulations based on ARFs.</p><p><strong>Results: </strong>A total of 196 children aged 24-84 months were screened (46.4% boys, mean age: 56.94 ± 17.52 months). The PlusOptix S12C demonstrated an overall sensitivity and specificity of 85.5% and 82.3%, respectively. Sensitivity for hyperopia (>4.00 D) was lower (47.7%), while specificity was 81.7%. For strabismus (>8 Δ), sensitivity and specificity were 67.8% and 91.1%, respectively. The device failed to produce readings in 21.9% of children, primarily those with significant refractive errors or strabismus.</p><p><strong>Conclusions: </strong>The PlusOptix S12C demonstrated good overall sensitivity and specificity for detecting ARFs, making it a valuable tool for large-scale paediatric vision screening, including in very young children. However, its inherent limitations in detecting high hyperopia and strabismus, combined with the high prevalence of these conditions in the untestable group, highlight the need for supplementary evaluation. Children who receive a 'no result' or 'unable-to-read' outcome on the device should be referred for a full examination, including cycloplegic refraction, to ensure ARFs are not missed. While the device aligns well with the 2021 AAPOS and MOH guidelines, careful attention to its limitations in high-risk subpopulations is essential to optimise screening efficacy and outcomes.</p>","PeriodicalId":19522,"journal":{"name":"Ophthalmic and Physiological Optics","volume":" ","pages":""},"PeriodicalIF":2.8000,"publicationDate":"2025-03-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ophthalmic and Physiological Optics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/opo.13484","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To evaluate the sensitivity and specificity of the PlusOptix S12C device in detecting amblyopia risk factors (ARFs) in children aged 2-7 years, in accordance with the 2020 Israeli Ministry of Health (MOH) directives and the 2021 American Association for Pediatric Ophthalmology and Strabismus (AAPOS) guidelines.

Methods: A cross-sectional, observational study was conducted at a tertiary care hospital. Children presenting for vision testing were screened using the PlusOptix S12C device, and results were compared with the gold standard cycloplegic refraction and cover test. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were calculated for the overall population and subpopulations based on ARFs.

Results: A total of 196 children aged 24-84 months were screened (46.4% boys, mean age: 56.94 ± 17.52 months). The PlusOptix S12C demonstrated an overall sensitivity and specificity of 85.5% and 82.3%, respectively. Sensitivity for hyperopia (>4.00 D) was lower (47.7%), while specificity was 81.7%. For strabismus (>8 Δ), sensitivity and specificity were 67.8% and 91.1%, respectively. The device failed to produce readings in 21.9% of children, primarily those with significant refractive errors or strabismus.

Conclusions: The PlusOptix S12C demonstrated good overall sensitivity and specificity for detecting ARFs, making it a valuable tool for large-scale paediatric vision screening, including in very young children. However, its inherent limitations in detecting high hyperopia and strabismus, combined with the high prevalence of these conditions in the untestable group, highlight the need for supplementary evaluation. Children who receive a 'no result' or 'unable-to-read' outcome on the device should be referred for a full examination, including cycloplegic refraction, to ensure ARFs are not missed. While the device aligns well with the 2021 AAPOS and MOH guidelines, careful attention to its limitations in high-risk subpopulations is essential to optimise screening efficacy and outcomes.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
5.10
自引率
13.80%
发文量
135
审稿时长
6-12 weeks
期刊介绍: Ophthalmic & Physiological Optics, first published in 1925, is a leading international interdisciplinary journal that addresses basic and applied questions pertinent to contemporary research in vision science and optometry. OPO publishes original research papers, technical notes, reviews and letters and will interest researchers, educators and clinicians concerned with the development, use and restoration of vision.
期刊最新文献
Effect of 0.025% atropine on ocular biometry changes during accommodation. Seasonal variation in axial elongation in children with orthokeratology treatment. Validation of the PlusOptix S12C for detecting amblyopia risk factors in a tertiary care young paediatric population. Influence of brightness artefacts on corneal densitometry. Subjective and objective measurements of the amplitude of accommodation: Revisiting the existing methods and clinical evaluation of newer techniques.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1