Impact of scapula anatomical landmark positioning on scapular orientation using CT-based 3-dimensional models: an intraobserver repeatability and interobserver reproducibility study

Q2 Medicine JSES International Pub Date : 2025-03-01 DOI:10.1016/j.jseint.2024.09.027
Florent Moissenet PhD , Sana Boudabbous MD, PhD , Nicolas Holzer MD, PhD
{"title":"Impact of scapula anatomical landmark positioning on scapular orientation using CT-based 3-dimensional models: an intraobserver repeatability and interobserver reproducibility study","authors":"Florent Moissenet PhD ,&nbsp;Sana Boudabbous MD, PhD ,&nbsp;Nicolas Holzer MD, PhD","doi":"10.1016/j.jseint.2024.09.027","DOIUrl":null,"url":null,"abstract":"<div><h3>Hypothesis</h3><div>The primary objective of this study was to assess intraobserver repeatability and interobserver reproducibility of the 3-dimensional (3D) coordinates of a set of scapula anatomical landmarks obtained by manual positioning on conventional supine computed tomography (CT) scan–based scapula surface models. The secondary objective was to assess intraobserver repeatability and interobserver reproducibility of the resulting 3D scapular orientation. It was hypothesized that the 3D scapular orientation reliability would be better or similar than established reliability of intraoperative baseplate positioning (ie, version and inclination) in reverse total shoulder arthroplasty.</div></div><div><h3>Methods</h3><div>Three anatomical landmarks, ie, acromial angle, inferior angle, and trigonum spinae, were manually positioned on 81 scapula surface models using updated landmark definitions. These models were obtained by the segmentation of CT scan images acquired from patients undergoing elective reverse total shoulder arthroplasty procedures at the Department of Surgery at Geneva University Hospitals between May 2022 and December 2023. This procedure was repeated 3 times per scapula by 3 independent observers. A set of parameters corresponding to the 3D landmark coordinates (expressed in an average scapula coordinate system) and the 3D scapular orientation (expressed as 3 angles related to the retraction/protraction, lateral/medial rotation, and internal/external rotation) were computed. Intraobserver repeatability and interobserver reproducibility were assessed for each of these parameters using an intraclass correlation coefficient (ICC) as a relative reliability metric. Standard error of measurement (SEM) was also reported as an absolute reliability metric.</div></div><div><h3>Results</h3><div>Intraobserver ICC and interobserver ICC ranged from poor to moderate for acromial angle, poor to excellent for inferior angle, and poor to excellent for trigonum spinae. However, low SEM, ranging from 0.4 mm to 2.4 mm for intraobserver repeatability and from 0.2 mm to 1.8 mm for interobserver reproducibility, was obtained for every coordinate of each anatomical landmark. This results in poor to moderate intraobserver ICC and interobserver ICC for scapula angular orientation. Again, low SEM, ranging from 0.4° to 0.8° for intraobserver repeatability and 0.4° to 0.6° for interobserver reproducibility, was obtained, arguing for reliable measurements.</div></div><div><h3>Discussion</h3><div>This study demonstrates that manual positioning of the 3 scapula anatomical landmarks recommended by the International Society of Biomechanics can be performed in a reliable manner across measures and observers on surface bone models obtained from CT scan images. However, a clear and standardized definition of these landmarks is needed to ensure consistency across measurements.</div></div>","PeriodicalId":34444,"journal":{"name":"JSES International","volume":"9 2","pages":"Pages 524-531"},"PeriodicalIF":0.0000,"publicationDate":"2025-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"JSES International","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2666638324004389","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Hypothesis

The primary objective of this study was to assess intraobserver repeatability and interobserver reproducibility of the 3-dimensional (3D) coordinates of a set of scapula anatomical landmarks obtained by manual positioning on conventional supine computed tomography (CT) scan–based scapula surface models. The secondary objective was to assess intraobserver repeatability and interobserver reproducibility of the resulting 3D scapular orientation. It was hypothesized that the 3D scapular orientation reliability would be better or similar than established reliability of intraoperative baseplate positioning (ie, version and inclination) in reverse total shoulder arthroplasty.

Methods

Three anatomical landmarks, ie, acromial angle, inferior angle, and trigonum spinae, were manually positioned on 81 scapula surface models using updated landmark definitions. These models were obtained by the segmentation of CT scan images acquired from patients undergoing elective reverse total shoulder arthroplasty procedures at the Department of Surgery at Geneva University Hospitals between May 2022 and December 2023. This procedure was repeated 3 times per scapula by 3 independent observers. A set of parameters corresponding to the 3D landmark coordinates (expressed in an average scapula coordinate system) and the 3D scapular orientation (expressed as 3 angles related to the retraction/protraction, lateral/medial rotation, and internal/external rotation) were computed. Intraobserver repeatability and interobserver reproducibility were assessed for each of these parameters using an intraclass correlation coefficient (ICC) as a relative reliability metric. Standard error of measurement (SEM) was also reported as an absolute reliability metric.

Results

Intraobserver ICC and interobserver ICC ranged from poor to moderate for acromial angle, poor to excellent for inferior angle, and poor to excellent for trigonum spinae. However, low SEM, ranging from 0.4 mm to 2.4 mm for intraobserver repeatability and from 0.2 mm to 1.8 mm for interobserver reproducibility, was obtained for every coordinate of each anatomical landmark. This results in poor to moderate intraobserver ICC and interobserver ICC for scapula angular orientation. Again, low SEM, ranging from 0.4° to 0.8° for intraobserver repeatability and 0.4° to 0.6° for interobserver reproducibility, was obtained, arguing for reliable measurements.

Discussion

This study demonstrates that manual positioning of the 3 scapula anatomical landmarks recommended by the International Society of Biomechanics can be performed in a reliable manner across measures and observers on surface bone models obtained from CT scan images. However, a clear and standardized definition of these landmarks is needed to ensure consistency across measurements.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
使用基于 CT 的三维模型进行肩胛骨解剖标志定位对肩胛骨定向的影响:观察者内重复性和观察者间再现性研究
假设本研究的主要目的是评估在传统仰卧位计算机断层扫描(CT)扫描的肩胛骨表面模型上,通过手动定位获得的一组肩胛骨解剖标志的三维(3D)坐标的观察者内重复性和观察者间可重复性。次要目的是评估由此产生的三维肩胛骨定位的观察者内可重复性和观察者间可重复性。我们假设在逆向全肩关节置换术中,三维肩胛骨定位的可靠性优于或类似于术中已建立的底板定位(即旋转和倾斜)的可靠性。方法采用更新后的标志定义,在81例肩胛骨表面模型上手工定位3个解剖标志,即肩峰角、下角和棘三角。这些模型是通过对日内瓦大学医院外科在2022年5月至2023年12月期间接受选择性反向全肩关节置换术的患者的CT扫描图像进行分割而获得的。该程序由3名独立观察员在每个肩胛骨重复3次。计算对应于三维地标坐标(以平均肩胛骨坐标系表示)和三维肩胛骨方位(以与收/伸、外侧/内侧旋转和内/外旋转相关的3个角度表示)的一组参数。使用类内相关系数(ICC)作为相对可靠性度量,评估每个参数的观察者内重复性和观察者间重复性。测量标准误差(SEM)也被报道为绝对可靠性度量。结果单观察者和间观察者ICC对肩峰角的评分从差到中等,对下角的评分从差到优,对棘三角的评分从差到优。然而,每个解剖地标的每个坐标都获得了较低的扫描电镜,观察者内重复性为0.4 mm至2.4 mm,观察者间重复性为0.2 mm至1.8 mm。这导致肩胛骨角取向的观察者内ICC和观察者间ICC差至中等。同样,低扫描电镜,观察者内重复性为0.4°至0.8°,观察者间重复性为0.4°至0.6°,证明测量是可靠的。本研究表明,国际生物力学学会推荐的3个肩胛骨解剖标志的手动定位可以在CT扫描图像获得的表面骨模型上以可靠的方式进行测量和观察。然而,需要对这些地标进行清晰和标准化的定义,以确保测量结果的一致性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
JSES International
JSES International Medicine-Surgery
CiteScore
2.80
自引率
0.00%
发文量
174
审稿时长
14 weeks
期刊最新文献
Arthroscopically assisted conjoined tendon-coracoid tip complex transfer combined with Bankart repair without screws for traumatic anterior recurrent shoulder instability: clinical and imaging outcomes Interest in computer-assisted surgery on the glenoid implant positioning in the context of navigated or planned total shoulder arthroplasties Two-year functional and radiographic outcomes of a convertible metaphyseal-based short humeral stem in anatomic shoulder arthroplasty: a comparison to stemless humeral components Radiomic analysis of the deltoid and scapula: identification of computed tomography-image based measurements predictive of pain, motion, and function before and after shoulder arthroplasty Clinical outcome of reverse total shoulder arthroplasty (comprehensive system) after failed rotator cuff repair with a medium-term follow-up: comparison with reverse total shoulder arthroplasty for massive rotator cuff tear without osteoarthritis
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1