PET imaging of functional 5-HT1A receptors with [18F]F13640: From PET kinetics modeling to static Standardized Uptake Values Ratio

IF 4.5 2区 医学 Q1 NEUROIMAGING NeuroImage Pub Date : 2025-03-08 DOI:10.1016/j.neuroimage.2025.121110
Pierre Courault , Inés Mérida , Nicolas Costes , Jérôme Redoute , Luc Zimmer , Sophie Lancelot
{"title":"PET imaging of functional 5-HT1A receptors with [18F]F13640: From PET kinetics modeling to static Standardized Uptake Values Ratio","authors":"Pierre Courault ,&nbsp;Inés Mérida ,&nbsp;Nicolas Costes ,&nbsp;Jérôme Redoute ,&nbsp;Luc Zimmer ,&nbsp;Sophie Lancelot","doi":"10.1016/j.neuroimage.2025.121110","DOIUrl":null,"url":null,"abstract":"<div><h3>Purpose</h3><div>F13640 is a highly selective serotonin 5-HT<sub>1A</sub> receptor ligand with agonist properties identified as a PET radiopharmaceutical candidate. In previous work, we showed the possibility to use long dynamic PET acquisition (225 min) combined with simplified kinetic modelling for [<sup>18</sup>F]F13640 quantification. In this work, we assessed the feasibility of static acquisition and quantification using standardized uptake value ratio (SUVR) as an alternative.</div></div><div><h3>Methods</h3><div>Test-retest PET-MRI scans of 225 min were conducted in eight healthy male volunteers. For 17 brain regions, distribution volume ratios (DVR) were calculated from the whole kinetics using Logan plot modelling method with the cerebellum white matter as reference region. For the same regions, SUVR were also calculated from static images, for four 20-minute and four 10-minute time-intervals at various time of uptake. Reliability between SUVR and DVR measures were studied, and test-retest parameters were assessed between PET sessions for each time-interval.</div></div><div><h3>Results</h3><div>Reproducibility of measures of SUVR compared to DVR were excellent, whatever the time interval (<em>p</em> &lt; 0.001). For the 20-min. time-intervals, SUVR<sub>150–170</sub> showed the best reproducibility and correlation parameters (R<sup>2</sup> = 0.95 ± 0.03, intercept = 0.06 ± 0.02, slope = 0.95 ± 0.01). As well, for the 10-min. time-intervals, SUVR<sub>150–160</sub> showed the best correlation (R<sup>2</sup> = 0.94 ± 0.03, intercept = 0.07 ± 0.02, slope = 0.94 ± 0.01). SUVR reproducibility between test-retest sessions was also excellent for each time-interval. These results were valid for pooled regions as well as at regional level.</div></div><div><h3>Conclusion</h3><div>This study confirms the feasibility of static acquisitions to facilitate clinical use of the [<sup>18</sup>F]F13640 radiopharmaceutical to image functional 5-HT<sub>1A</sub> receptors. This involves off-camera injection, 10 to 20 mins static acquisition duration, and quantification using SUVR, while improving patient comfort.</div></div>","PeriodicalId":19299,"journal":{"name":"NeuroImage","volume":"310 ","pages":"Article 121110"},"PeriodicalIF":4.5000,"publicationDate":"2025-03-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"NeuroImage","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1053811925001120","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"NEUROIMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose

F13640 is a highly selective serotonin 5-HT1A receptor ligand with agonist properties identified as a PET radiopharmaceutical candidate. In previous work, we showed the possibility to use long dynamic PET acquisition (225 min) combined with simplified kinetic modelling for [18F]F13640 quantification. In this work, we assessed the feasibility of static acquisition and quantification using standardized uptake value ratio (SUVR) as an alternative.

Methods

Test-retest PET-MRI scans of 225 min were conducted in eight healthy male volunteers. For 17 brain regions, distribution volume ratios (DVR) were calculated from the whole kinetics using Logan plot modelling method with the cerebellum white matter as reference region. For the same regions, SUVR were also calculated from static images, for four 20-minute and four 10-minute time-intervals at various time of uptake. Reliability between SUVR and DVR measures were studied, and test-retest parameters were assessed between PET sessions for each time-interval.

Results

Reproducibility of measures of SUVR compared to DVR were excellent, whatever the time interval (p < 0.001). For the 20-min. time-intervals, SUVR150–170 showed the best reproducibility and correlation parameters (R2 = 0.95 ± 0.03, intercept = 0.06 ± 0.02, slope = 0.95 ± 0.01). As well, for the 10-min. time-intervals, SUVR150–160 showed the best correlation (R2 = 0.94 ± 0.03, intercept = 0.07 ± 0.02, slope = 0.94 ± 0.01). SUVR reproducibility between test-retest sessions was also excellent for each time-interval. These results were valid for pooled regions as well as at regional level.

Conclusion

This study confirms the feasibility of static acquisitions to facilitate clinical use of the [18F]F13640 radiopharmaceutical to image functional 5-HT1A receptors. This involves off-camera injection, 10 to 20 mins static acquisition duration, and quantification using SUVR, while improving patient comfort.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用[18F]F13640 对功能性 5-HT1A 受体进行 PET 成像:从 PET 动力学建模到静态标准化摄取值比率
f13640是一种具有激动剂特性的高选择性5-羟色胺5-HT1A受体配体,被确定为PET放射性药物候选物。在之前的工作中,我们展示了使用长时间动态PET采集(225分钟)结合简化动力学建模进行[18F]F13640定量的可能性。在这项工作中,我们评估了使用标准化吸收值比(SUVR)作为替代方案的静态采集和量化的可行性。方法对8名健康男性志愿者进行225 min的PET-MRI扫描。以小脑白质为参照区,采用Logan图建模法从全动力学角度计算17个脑区分布体积比(DVR)。对于同一区域,SUVR也从静态图像中计算,在不同的摄取时间,分别为4个20分钟和4个10分钟的时间间隔。研究了SUVR和DVR测量之间的可靠性,并评估了每个时间间隔的PET测试之间的测试重测参数。结果与DVR相比,无论时间间隔如何,SUVR测量结果的重现性都很好(p <;0.001)。20分钟。时间间隔中,suvr150 ~ 170具有最佳的重复性和相关参数(R2 = 0.95±0.03,截距= 0.06±0.02,斜率= 0.95±0.01)。10分钟也一样。时间间隔上,suvr150 ~ 160的相关性最佳(R2 = 0.94±0.03,截距= 0.07±0.02,斜率= 0.94±0.01)。对于每个时间间隔,测试-重测试会话之间的SUVR再现性也很好。这些结果对合并区域和区域水平都有效。结论本研究证实了静态获取的可行性,便于临床使用[18F]F13640放射性药物对功能性5-HT1A受体进行成像。这包括相机外注射,10至20分钟的静态采集时间,并使用SUVR进行量化,同时提高患者的舒适度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
NeuroImage
NeuroImage 医学-核医学
CiteScore
11.30
自引率
10.50%
发文量
809
审稿时长
63 days
期刊介绍: NeuroImage, a Journal of Brain Function provides a vehicle for communicating important advances in acquiring, analyzing, and modelling neuroimaging data and in applying these techniques to the study of structure-function and brain-behavior relationships. Though the emphasis is on the macroscopic level of human brain organization, meso-and microscopic neuroimaging across all species will be considered if informative for understanding the aforementioned relationships.
期刊最新文献
Maturation and reorganization of structural connectivity in infants within half a year A nap can recalibrate homeostatic and associative synaptic plasticity in the human cortex. Four-dimensional neural space for moral inference. Brain activity inhibition during Short Video Viewing: neurochemical insights. CT-free attenuation and scatter correction of [11C]CFT brain PET using a Bi-directional matching network
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1