{"title":"Implantable cardiac defibrillator outcomes in octogenarians","authors":"Muhammad Rehan Zahid MBBS,&nbsp;Syed Tawassul Hassan MBBS,&nbsp;Muhammad Shaheer Bin Faheem MBBS,&nbsp;Aleeza Rehman MBBS,&nbsp;Syed Muhammad Ali MD","doi":"10.1002/joa3.70039","DOIUrl":null,"url":null,"abstract":"<p>We read the article “Implantable cardiac defibrillator outcomes in octogenarians” and appreciate the authors, Stringer et al., for their efforts in examining the outcomes of implantable cardiac defibrillator (ICD) in overlooked elderly population (80 or &lt;) having increased susceptibility to sudden cardiac death (SCD).<span><sup>1</sup></span> We highly commend their work for analyzing outcomes like mortality, frailty, and usage frequency related to ICD treatment and acknowledge their contribution to the ongoing discussion of ICD therapy in older adults. However, we found several methodological gaps that can significantly affect this study's findings.</p><p>Firstly, the study relied on univariate statistical tests without any multivariate adjustments. This can fail to provide the accurate relationship of covariates such as demographics that include age and gender and comorbidities like hypertension, diabetes, and atrial fibrillation with the study outcomes, excluding necessary confounders that can significantly impact the effect of ICD and study conclusions.<span><sup>2</sup></span> Although the Dalhousie frailty score helps in risk stratification and better frailty assessment in octogenarians, it requires detailed data on patients' health conditions, while the study documented a significant loss of device records and follow-up data that can lead to inaccurate findings. Further, it requires subjective clinical judgment rather than relying on medical records, as in this study. Authors had assumed the patients to be alive who had a clinical or emergency visit in the last 3 months of the study, inducing misclassification bias as the patients who were not able to report due to any reason might be classified as dead, distorting mortality outcomes. Among patients in the primary prevention group, a set threshold of 188 bpm for ventricular tachycardia (VT)/Ventricular fibrillation (VF) is not suitable for those who experience severe arrhythmias at lower cardiac rates, and a nonindividualized programming approach can cause excessive shocks affecting the quality of life of these patients.<span><sup>3</sup></span> Also, aggressive ATP usage before shocks can delay the needed shocks for patients with prolonged ventricular arrhythmias.<span><sup>3</sup></span> A total of five patients (6.3%) were classified as critically frail; this underpowered subgroup analysis can increase the risk of type 2 errors, undermining the outcomes of this study.<span><sup>4</sup></span> Women have a higher risk of procedural and postimplantation ICD-related complications, but only 14% of the total population of this study were female, limiting the generalizability of findings toward the female population.<span><sup>5</sup></span></p><p>Lastly, to control confounders, we recommend using multivariable regressions and adapting the electronic frailty index designed for retrospective study designs to enhance the data's reliability. However, misclassification bias can be avoided by linking records with national databases for death registries, and the ICD programming protocol should be individualized to improve patient outcomes. Further, upscaling sample sizes of subgroups and demographics would increase the statistical power and generalizability of the study.</p><p>None.</p>","PeriodicalId":15174,"journal":{"name":"Journal of Arrhythmia","volume":"41 2","pages":""},"PeriodicalIF":2.2000,"publicationDate":"2025-03-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1002/joa3.70039","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Arrhythmia","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/joa3.70039","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

We read the article “Implantable cardiac defibrillator outcomes in octogenarians” and appreciate the authors, Stringer et al., for their efforts in examining the outcomes of implantable cardiac defibrillator (ICD) in overlooked elderly population (80 or <) having increased susceptibility to sudden cardiac death (SCD).1 We highly commend their work for analyzing outcomes like mortality, frailty, and usage frequency related to ICD treatment and acknowledge their contribution to the ongoing discussion of ICD therapy in older adults. However, we found several methodological gaps that can significantly affect this study's findings.

Firstly, the study relied on univariate statistical tests without any multivariate adjustments. This can fail to provide the accurate relationship of covariates such as demographics that include age and gender and comorbidities like hypertension, diabetes, and atrial fibrillation with the study outcomes, excluding necessary confounders that can significantly impact the effect of ICD and study conclusions.2 Although the Dalhousie frailty score helps in risk stratification and better frailty assessment in octogenarians, it requires detailed data on patients' health conditions, while the study documented a significant loss of device records and follow-up data that can lead to inaccurate findings. Further, it requires subjective clinical judgment rather than relying on medical records, as in this study. Authors had assumed the patients to be alive who had a clinical or emergency visit in the last 3 months of the study, inducing misclassification bias as the patients who were not able to report due to any reason might be classified as dead, distorting mortality outcomes. Among patients in the primary prevention group, a set threshold of 188 bpm for ventricular tachycardia (VT)/Ventricular fibrillation (VF) is not suitable for those who experience severe arrhythmias at lower cardiac rates, and a nonindividualized programming approach can cause excessive shocks affecting the quality of life of these patients.3 Also, aggressive ATP usage before shocks can delay the needed shocks for patients with prolonged ventricular arrhythmias.3 A total of five patients (6.3%) were classified as critically frail; this underpowered subgroup analysis can increase the risk of type 2 errors, undermining the outcomes of this study.4 Women have a higher risk of procedural and postimplantation ICD-related complications, but only 14% of the total population of this study were female, limiting the generalizability of findings toward the female population.5

Lastly, to control confounders, we recommend using multivariable regressions and adapting the electronic frailty index designed for retrospective study designs to enhance the data's reliability. However, misclassification bias can be avoided by linking records with national databases for death registries, and the ICD programming protocol should be individualized to improve patient outcomes. Further, upscaling sample sizes of subgroups and demographics would increase the statistical power and generalizability of the study.

None.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
相关文献
Study of the Nutritional and Hypoglycemic Effects of <i>Soumbara</i> <i>(Parkia biglobosa</i>) and <i>Moringa </i>(<i>Moringa oleifera</i>) Leaf Formulations on Mouse (<i>Mus musculus</i>)
IF 0 American Journal of Food and NutritionPub Date : 2023-10-06 DOI: 10.12691/ajfn-11-3-4
Karnon Coulibaly, Fatoumata Camara, Ekoua Regina Krabi, Wahauwouele Hermann Coulibaly, Brahima Kande, Koffi Cyrille Tan
来源期刊
Journal of Arrhythmia
Journal of Arrhythmia CARDIAC & CARDIOVASCULAR SYSTEMS-
CiteScore
2.90
自引率
10.00%
发文量
127
审稿时长
45 weeks
期刊最新文献
“A on V” tachycardia in a patient with diseased His bundle Does organized atrial tachycardia after a pulmonary vein isolation-only procedure portend better outcome of repeat ablation compared to recurrent atrial fibrillation? Editorial to “Impact of intracardiac pattern matching settings on the activation map of accessory pathways using open window mapping” A new scoring system to predict the risk of late recurrence in extended follow-up after atrial fibrillation catheter ablation: APCEL score Leadless pacemaker implantation in real-world clinical practice: An Italian survey promoted by the AIAC (Italian Association of Arrhythmology and Cardiac Pacing)
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1