Novel non-invasive and quantitative assessment of the renal function of transplanted kidneys using Doppler ultrasonography with the vascular index of superb microvascular imaging.

IF 2.5 3区 医学 Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Ultrasonography Pub Date : 2025-03-01 Epub Date: 2025-02-12 DOI:10.14366/usg.24176
Sung Hwan Bae, Eun Ji Lee, Jiyoung Hwang, Seong Sook Hong, Yun-Woo Chang, Boda Nam
{"title":"Novel non-invasive and quantitative assessment of the renal function of transplanted kidneys using Doppler ultrasonography with the vascular index of superb microvascular imaging.","authors":"Sung Hwan Bae, Eun Ji Lee, Jiyoung Hwang, Seong Sook Hong, Yun-Woo Chang, Boda Nam","doi":"10.14366/usg.24176","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>This study assessed the reproducibility and clinical value of the vascular index (VI), derived from superb microvascular imaging (SMI) using Doppler ultrasonography, for evaluating renal function in transplanted kidneys.</p><p><strong>Methods: </strong>This retrospective study included 63 renal transplant patients who underwent grayscale and Doppler ultrasonography with SMI from January 2022 to February 2023. The VI of the transplanted kidneys was measured using three methods (VIbox, VIF1, VIF2). The VI was compared across chronic kidney disease (CKD) groups categorized by estimated glomerular filtration rate (eGFR) and Kidney Disease: Improving Global Outcomes (KDIGO) CKD risk groups based on eGFR and albuminuria. The correlation between VI and renal function was evaluated. Univariate and multivariate linear regression analyses were used to identify predictors of eGFR.</p><p><strong>Results: </strong>Significant differences in VI were observed among CKD groups based on eGFR (VIbox, P=0.001; VIF1, P<0.001; VIF2, P<0.001) and KDIGO CKD groups based on eGFR and albuminuria (VIbox, P=0.039; VIF1, P=0.001; VIF2, P<0.001). VIF1 and VIF2 demonstrated moderate/high correlations with eGFR (r=0.627, P<0.001 and r=0.657, P<0.001, respectively) and serum creatinine (r=-0.626, P<0.001 and r=-0.649, P<0.001, respectively). VIbox moderately correlated with eGFR (r=0.445, P<0.001). Multivariate regression identified the urine albumincreatinine ratio (ACR) (adjusted odds ratio [aOR], 1.122; 95% confidence interval [CI], -0.007 to, 0.000; P=0.030) and VIF2 (aOR, 1.114; 95% CI, 0.466 to 1.235; P<0.001) were independently associated with eGFR.</p><p><strong>Conclusion: </strong>The VI measured by drawing a region of interest along the border of the transplanted kidney in SMI (VIF2) is highly reproducible and correlates well with eGFR. Both VIF2 and ACR independently predict eGFR.</p>","PeriodicalId":54227,"journal":{"name":"Ultrasonography","volume":"44 2","pages":"160-169"},"PeriodicalIF":2.5000,"publicationDate":"2025-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11938797/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ultrasonography","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.14366/usg.24176","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/2/12 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: This study assessed the reproducibility and clinical value of the vascular index (VI), derived from superb microvascular imaging (SMI) using Doppler ultrasonography, for evaluating renal function in transplanted kidneys.

Methods: This retrospective study included 63 renal transplant patients who underwent grayscale and Doppler ultrasonography with SMI from January 2022 to February 2023. The VI of the transplanted kidneys was measured using three methods (VIbox, VIF1, VIF2). The VI was compared across chronic kidney disease (CKD) groups categorized by estimated glomerular filtration rate (eGFR) and Kidney Disease: Improving Global Outcomes (KDIGO) CKD risk groups based on eGFR and albuminuria. The correlation between VI and renal function was evaluated. Univariate and multivariate linear regression analyses were used to identify predictors of eGFR.

Results: Significant differences in VI were observed among CKD groups based on eGFR (VIbox, P=0.001; VIF1, P<0.001; VIF2, P<0.001) and KDIGO CKD groups based on eGFR and albuminuria (VIbox, P=0.039; VIF1, P=0.001; VIF2, P<0.001). VIF1 and VIF2 demonstrated moderate/high correlations with eGFR (r=0.627, P<0.001 and r=0.657, P<0.001, respectively) and serum creatinine (r=-0.626, P<0.001 and r=-0.649, P<0.001, respectively). VIbox moderately correlated with eGFR (r=0.445, P<0.001). Multivariate regression identified the urine albumincreatinine ratio (ACR) (adjusted odds ratio [aOR], 1.122; 95% confidence interval [CI], -0.007 to, 0.000; P=0.030) and VIF2 (aOR, 1.114; 95% CI, 0.466 to 1.235; P<0.001) were independently associated with eGFR.

Conclusion: The VI measured by drawing a region of interest along the border of the transplanted kidney in SMI (VIF2) is highly reproducible and correlates well with eGFR. Both VIF2 and ACR independently predict eGFR.

Abstract Image

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于微血管成像血管指数的多普勒超声对移植肾肾功能的无创定量评价。
目的:本研究评估多普勒超声超细微血管成像(SMI)血管指数(VI)在评价移植肾肾功能中的可重复性和临床价值。方法:本回顾性研究包括63例肾移植患者,这些患者于2022年1月至2023年2月期间接受了灰度和多普勒超声检查。采用三种方法(VIbox、VIF1、VIF2)测定移植肾的VI。根据肾小球滤过率(eGFR)和基于eGFR和蛋白尿的肾脏疾病:改善总体预后(KDIGO) CKD风险组对慢性肾脏疾病(CKD)组的VI进行比较。评估VI与肾功能的相关性。采用单变量和多变量线性回归分析来确定eGFR的预测因子。结果:基于eGFR的CKD组间VI有显著差异(VIbox, P=0.001;结论:SMI患者通过沿移植肾边界绘制感兴趣区域测量的VI (VIF2)具有高度可重复性,且与eGFR相关性良好。VIF2和ACR均可独立预测eGFR。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Ultrasonography
Ultrasonography Medicine-Radiology, Nuclear Medicine and Imaging
CiteScore
5.10
自引率
6.50%
发文量
78
审稿时长
15 weeks
期刊介绍: Ultrasonography, the official English-language journal of the Korean Society of Ultrasound in Medicine (KSUM), is an international peer-reviewed academic journal dedicated to practice, research, technology, and education dealing with medical ultrasound. It is renamed from the Journal of Korean Society of Ultrasound in Medicine in January 2014, and published four times per year: January 1, April 1, July 1, and October 1. Original articles, technical notes, topical reviews, perspectives, pictorial essays, and timely editorial materials are published in Ultrasonography covering state-of-the-art content. Ultrasonography aims to provide updated information on new diagnostic concepts and technical developments, including experimental animal studies using new equipment in addition to well-designed reviews of contemporary issues in patient care. Along with running KSUM Open, the annual international congress of KSUM, Ultrasonography also serves as a medium for cooperation among physicians and specialists from around the world who are focusing on various ultrasound technology and disease problems and relevant basic science.
期刊最新文献
Erratum: Potential role of two-dimensional shear wave elastography, including liver stiffness measurement and dispersion slope, for management of chronic hepatitis B. Additive predictive value of preoperative thyroid ultrasound parameters for postoperative hypothyroidism after hemithyroidectomy: a single-center retrospective study. Effect of prophylactic platelet transfusion on bleeding risk in patients with cirrhosis and thrombocytopenia undergoing ultrasound-guided liver biopsy. HUMaN: Handheld Ultrasound System with Magnetic Needle Navigation. Monitoring of low-risk pancreatic cystic lesions with targeted abdominal ultrasound: diagnostic yield, clinical utility, and acceptance.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1