{"title":"Inter-Software Reproducibility of Quantitative Values of Myocardial Blood Flow and Coronary Flow Reserve Acquired by [<sup>13</sup>N]NH<sub>3</sub> MPI PET/CT and the Effect of Motion Correction Tools.","authors":"Oscar Isaac Mendoza-Ibañez, Riemer H J A Slart, Erick Alexanderson-Rosas, Tonantzin Samara Martinez-Lucio, Friso M van der Zant, Remco J J Knol, Sergiy V Lazarenko","doi":"10.3390/diagnostics15050613","DOIUrl":null,"url":null,"abstract":"<p><p><b>Background:</b> The choice of software package (SP) for image processing affects the reproducibility of myocardial blood flow (MBF) values in [<sup>13</sup>N]NH<sub>3</sub> PET/CT scans. However, the impact of motion correction (MC) tools-integrated software motion correction (ISMC) or data-driven motion correction (DDMC)-on the inter-software reproducibility of MBF has not been studied. This research aims to evaluate reproducibility among three commonly used SPs and the role of MC. <b>Methods:</b> Thirty-six PET/CT studies from patients without myocardial ischemia or infarction were processed using QPET, Corridor-4DM (4DM), and syngo.MBF (syngo). MBF and coronary flow reserve (CFR) values were obtained without motion correction (NMC) and with ISMC and DDMC. Intraclass correlation coefficients (ICC) and Bland-Altman (BA) plots were used to analyze agreement. <b>Results:</b> Good or excellent reproducibility (ICC ≥ 0.77) was found for rest-MBF values, regardless of the SPs or use of MC. In contrast, stress-MBF and CFR values presented mostly a moderate agreement when NMC was used. The RCA territory consistently had the lowest agreement in stress-MBF and CFR in the comparisons involving QPET. The use of MC, particularly DDMC, enhanced the reproducibility of most of the stress-MBF and CFR values by improving ICCs and reducing bias and limits of agreement (LoA) in BA analysis. <b>Conclusions:</b> MBF quantification agreement between SPs is strong for rest-MBF values but suboptimal for stress-MBF and CFR values. MC tools, especially DDMC, are recommended for improving reproducibility in stress-MBF assessments, although differences in SP reproducibility up to 0.77 mL/g/min in global stress-MBF and up to 0.88 in global CFR remain despite the use of MC.</p>","PeriodicalId":11225,"journal":{"name":"Diagnostics","volume":"15 5","pages":""},"PeriodicalIF":3.3000,"publicationDate":"2025-03-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11898590/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Diagnostics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3390/diagnostics15050613","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
引用次数: 0

Abstract

Background: The choice of software package (SP) for image processing affects the reproducibility of myocardial blood flow (MBF) values in [13N]NH3 PET/CT scans. However, the impact of motion correction (MC) tools-integrated software motion correction (ISMC) or data-driven motion correction (DDMC)-on the inter-software reproducibility of MBF has not been studied. This research aims to evaluate reproducibility among three commonly used SPs and the role of MC. Methods: Thirty-six PET/CT studies from patients without myocardial ischemia or infarction were processed using QPET, Corridor-4DM (4DM), and syngo.MBF (syngo). MBF and coronary flow reserve (CFR) values were obtained without motion correction (NMC) and with ISMC and DDMC. Intraclass correlation coefficients (ICC) and Bland-Altman (BA) plots were used to analyze agreement. Results: Good or excellent reproducibility (ICC ≥ 0.77) was found for rest-MBF values, regardless of the SPs or use of MC. In contrast, stress-MBF and CFR values presented mostly a moderate agreement when NMC was used. The RCA territory consistently had the lowest agreement in stress-MBF and CFR in the comparisons involving QPET. The use of MC, particularly DDMC, enhanced the reproducibility of most of the stress-MBF and CFR values by improving ICCs and reducing bias and limits of agreement (LoA) in BA analysis. Conclusions: MBF quantification agreement between SPs is strong for rest-MBF values but suboptimal for stress-MBF and CFR values. MC tools, especially DDMC, are recommended for improving reproducibility in stress-MBF assessments, although differences in SP reproducibility up to 0.77 mL/g/min in global stress-MBF and up to 0.88 in global CFR remain despite the use of MC.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
[13N]NH3 MPI PET/CT获取心肌血流量和冠状动脉血流储备定量值的软件间可重复性及运动校正工具的影响
背景:图像处理软件包(SP)的选择影响[13N]NH3 PET/CT扫描心肌血流量(MBF)值的再现性。然而,运动校正(MC)工具——集成软件运动校正(ISMC)或数据驱动运动校正(DDMC)对MBF软件间再现性的影响尚未得到研究。本研究旨在评估三种常用SPs的可重复性以及MC的作用。方法:对36例无心肌缺血或梗死患者的PET/CT研究进行QPET、Corridor-4DM和syngo处理。兆(syngo)。在不进行运动校正(NMC)、ISMC和DDMC的情况下获得MBF和冠状动脉血流储备(CFR)值。用类内相关系数(ICC)和Bland-Altman (BA)图分析一致性。结果:无论sp或使用MC,休息- mbf值的重现性均良好或极好(ICC≥0.77)。相反,使用NMC时,应力- mbf和CFR值基本一致。在涉及QPET的比较中,RCA区域在压力- mbf和CFR方面的一致性最低。MC,特别是DDMC的使用,通过改善ICCs和减少BA分析中的偏差和一致限(LoA),提高了大多数应力- mbf和CFR值的可重复性。结论:sp之间的MBF量化一致性在休息-MBF值上很强,但在应力-MBF和CFR值上不太理想。MC工具,尤其是DDMC,被推荐用于提高应力- mbf评估的再现性,尽管使用MC,总体应力- mbf的SP再现性差异高达0.77 mL/g/min,总体CFR的SP再现性差异高达0.88 mL/g/min。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Diagnostics
Diagnostics Biochemistry, Genetics and Molecular Biology-Clinical Biochemistry
CiteScore
4.70
自引率
8.30%
发文量
2699
审稿时长
19.64 days
期刊介绍: Diagnostics (ISSN 2075-4418) is an international scholarly open access journal on medical diagnostics. It publishes original research articles, reviews, communications and short notes on the research and development of medical diagnostics. There is no restriction on the length of the papers. Our aim is to encourage scientists to publish their experimental and theoretical research in as much detail as possible. Full experimental and/or methodological details must be provided for research articles.
期刊最新文献
Retrospective Multicenter Analysis of Withdrawal Syndrome in Parkinson's Disease Patients After Cessation of Deep Brain Stimulation. Psychological Morbidity After Ocular Trauma: Association Between Initial Visual Loss and PTSD. Breast Cancer Classification Using Feature Selection via Improved Simulated Annealing and SVM Classifier. Beyond the Image Frame: An Art-Based Pedagogical Framework for Teaching Diagnostic Reasoning in Breast Ultrasound to Medical Students. Comprehensive Sonographic Paradigm and Trend Pattern of Median Nerve Indices in Carpal Tunnel Syndrome from Wrist to Forearm: What We Need to Know.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1