Safety and complications of antimicrobial coated compared to conventional intramedullary femoral nails in proximal femoral fractures.

IF 1.9 3区 医学 Q2 EMERGENCY MEDICINE European Journal of Trauma and Emergency Surgery Pub Date : 2025-03-12 DOI:10.1007/s00068-025-02809-7
Jacob Wiechert, Georg Osterhoff, Christian Kleber, Andreas Höch, Dmitry Notov
{"title":"Safety and complications of antimicrobial coated compared to conventional intramedullary femoral nails in proximal femoral fractures.","authors":"Jacob Wiechert, Georg Osterhoff, Christian Kleber, Andreas Höch, Dmitry Notov","doi":"10.1007/s00068-025-02809-7","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The aim of this study was to compare one-year mortality and the incidence of complications, particularly fracture-related infections, between patients with proximal femur fractures treated with novel noble metal-coated implants and those treated with uncoated implants, to detect possible effects of the coating on these endpoints.</p><p><strong>Methods: </strong>Design: Retrospective cohort observational study.</p><p><strong>Setting: </strong>Level 1 trauma centre. Patient Selection Criteria: All patients ≥ 18 years old with proximal femur fracture, who were treated with an intramedullary femur nail between 01.09.2020 and 01.10.2022 were included. The coated group (COATED) included patients who were treated with a coated implant. The control group (CONTROL) was treated with uncoated implants. Pathological fractures were excluded.</p><p><strong>Results: </strong>188 patients who matched the criteria were included (COATED: 93, CONTROL: 95). There was no significant difference in the one-year mortality or complication rate between the two groups. The fracture-related infection rate did not differ (p = 0.31) between both groups. Complications were observed in 59% of all cases and the overall one-year mortality rate was 42%. There was a significant correlation between complication occurrence and hospital stay (p < 0.01).</p><p><strong>Conclusion: </strong>The coated intramedullary nail was similar to the uncoated nail in terms of perioperative complications and 1-year mortality rate. This suggests that the novel coated implant is safe for common clinical use. Further prospective multicentre studies with larger sample sizes are needed to detect a potential impact of coated implants on the incidence of fracture-related infections.</p>","PeriodicalId":12064,"journal":{"name":"European Journal of Trauma and Emergency Surgery","volume":"51 1","pages":"132"},"PeriodicalIF":1.9000,"publicationDate":"2025-03-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11903581/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Trauma and Emergency Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00068-025-02809-7","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"EMERGENCY MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: The aim of this study was to compare one-year mortality and the incidence of complications, particularly fracture-related infections, between patients with proximal femur fractures treated with novel noble metal-coated implants and those treated with uncoated implants, to detect possible effects of the coating on these endpoints.

Methods: Design: Retrospective cohort observational study.

Setting: Level 1 trauma centre. Patient Selection Criteria: All patients ≥ 18 years old with proximal femur fracture, who were treated with an intramedullary femur nail between 01.09.2020 and 01.10.2022 were included. The coated group (COATED) included patients who were treated with a coated implant. The control group (CONTROL) was treated with uncoated implants. Pathological fractures were excluded.

Results: 188 patients who matched the criteria were included (COATED: 93, CONTROL: 95). There was no significant difference in the one-year mortality or complication rate between the two groups. The fracture-related infection rate did not differ (p = 0.31) between both groups. Complications were observed in 59% of all cases and the overall one-year mortality rate was 42%. There was a significant correlation between complication occurrence and hospital stay (p < 0.01).

Conclusion: The coated intramedullary nail was similar to the uncoated nail in terms of perioperative complications and 1-year mortality rate. This suggests that the novel coated implant is safe for common clinical use. Further prospective multicentre studies with larger sample sizes are needed to detect a potential impact of coated implants on the incidence of fracture-related infections.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
4.50
自引率
14.30%
发文量
311
审稿时长
3 months
期刊介绍: The European Journal of Trauma and Emergency Surgery aims to open an interdisciplinary forum that allows for the scientific exchange between basic and clinical science related to pathophysiology, diagnostics and treatment of traumatized patients. The journal covers all aspects of clinical management, operative treatment and related research of traumatic injuries. Clinical and experimental papers on issues relevant for the improvement of trauma care are published. Reviews, original articles, short communications and letters allow the appropriate presentation of major and minor topics.
期刊最新文献
Conventional Coagulation Tests are a better predictor of mortality than Viscoelastic Haemostatic Assays in trauma patients with shock: a prospective observational study. Injury patterns and patient outcomes of abdominal trauma in the elderly population: a 5-year experience of a Major Trauma Centre. Major trauma and comorbidity: a scoping review. Safety and complications of antimicrobial coated compared to conventional intramedullary femoral nails in proximal femoral fractures. Comparison of elastic stable intramedullary nailing versus retrograde screw fixation for pubic ramus fractures-a biomechanical study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1