{"title":"Sensitive Detection of Shorted Field Winding Turns in Salient Pole Synchronous Machines With High Frequency Pole Drop Test","authors":"Muhammad Faizan Shaikh;Byambasuren Battulga;Anyuan Chen;Arne Nysveen;Hossein Ehya;Kyeongyeol Kim;Baekkyeong Ko;Sang Bin Lee","doi":"10.1109/TEC.2025.3551569","DOIUrl":null,"url":null,"abstract":"The pole drop test is the most widely accepted test for detecting short circuits in the field winding of salient pole synchronous machines (SPSM). Although it is a simple and effective test, there are concerns on the reliability due to the inherent asymmetry between the poles, especially for cases where the percentage of shorted turns is low. Considering that this is the primary test used in industry for detecting shorted field turns in SPSMs, improving the sensitivity of the test is highly desirable for reliable fault detection. In this paper, it is shown that the sensitivity of the pole drop test can be significantly improved by increasing the excitation frequency of the test voltage above the 50/60 Hz currently used, which is not reported elsewhere. An electrical equivalent circuit analysis and an experimental study on a 4 pole, 30 kVA synchronous motor and a 14 pole, 100 kVA hydrogenator prototype are given to verify the claims made.","PeriodicalId":13211,"journal":{"name":"IEEE Transactions on Energy Conversion","volume":"40 2","pages":"1686-1689"},"PeriodicalIF":5.4000,"publicationDate":"2025-03-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Transactions on Energy Conversion","FirstCategoryId":"5","ListUrlMain":"https://ieeexplore.ieee.org/document/10925859/","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENERGY & FUELS","Score":null,"Total":0}
引用次数: 0

Abstract

The pole drop test is the most widely accepted test for detecting short circuits in the field winding of salient pole synchronous machines (SPSM). Although it is a simple and effective test, there are concerns on the reliability due to the inherent asymmetry between the poles, especially for cases where the percentage of shorted turns is low. Considering that this is the primary test used in industry for detecting shorted field turns in SPSMs, improving the sensitivity of the test is highly desirable for reliable fault detection. In this paper, it is shown that the sensitivity of the pole drop test can be significantly improved by increasing the excitation frequency of the test voltage above the 50/60 Hz currently used, which is not reported elsewhere. An electrical equivalent circuit analysis and an experimental study on a 4 pole, 30 kVA synchronous motor and a 14 pole, 100 kVA hydrogenator prototype are given to verify the claims made.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
凸极同步电机绕组短场匝的高频跌落试验灵敏检测
在凸极同步电机(SPSM)励磁绕组短路检测中,极降检测是目前应用最广泛的一种检测方法。虽然这是一个简单而有效的测试,但由于两极之间固有的不对称性,特别是在短匝数百分比较低的情况下,人们对可靠性存在担忧。考虑到这是工业上用于检测spsm短场匝的主要测试,提高测试的灵敏度对于可靠的故障检测是非常可取的。本文表明,通过提高目前使用的50/60 Hz以上的试验电压的激励频率,可以显著提高极降试验的灵敏度,这在其他地方没有报道。通过对4极30kva同步电动机和14极100kva加氢器样机的等效电路分析和实验研究,验证了上述说法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
IEEE Transactions on Energy Conversion
IEEE Transactions on Energy Conversion 工程技术-工程:电子与电气
CiteScore
11.10
自引率
10.20%
发文量
230
审稿时长
4.2 months
期刊介绍: The IEEE Transactions on Energy Conversion includes in its venue the research, development, design, application, construction, installation, operation, analysis and control of electric power generating and energy storage equipment (along with conventional, cogeneration, nuclear, distributed or renewable sources, central station and grid connection). The scope also includes electromechanical energy conversion, electric machinery, devices, systems and facilities for the safe, reliable, and economic generation and utilization of electrical energy for general industrial, commercial, public, and domestic consumption of electrical energy.
期刊最新文献
Blank Page IEEE Transactions on Energy Conversion Information for Authors IEEE Power & Energy Society Information Best Papers and Star Reviewers S-Parameters as a Basis for Stator Model Parameter Extraction and SFRA Interpretation
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1