Effectiveness and safety of three NiTi systems in endodontic retreatment of MB1 and MB2 root canals: a micro-CT and CBCT combined analysis.

IF 3.1 2区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE Clinical Oral Investigations Pub Date : 2025-03-19 DOI:10.1007/s00784-025-06273-w
Airton Oliveira Santos-Junior, Rocharles Cavalcante Fontenele, Karina Ines Medina Carita Tavares, Fernanda Ferrari Esteves Torres, Jáder Camilo Pinto, Pedro Luis Busto Rosim, Andréa Gonçalves, Marco Antonio Hungaro Duarte, Juliane Maria Guerreiro-Tanomaru, Mário Tanomaru-Filho
{"title":"Effectiveness and safety of three NiTi systems in endodontic retreatment of MB1 and MB2 root canals: a micro-CT and CBCT combined analysis.","authors":"Airton Oliveira Santos-Junior, Rocharles Cavalcante Fontenele, Karina Ines Medina Carita Tavares, Fernanda Ferrari Esteves Torres, Jáder Camilo Pinto, Pedro Luis Busto Rosim, Andréa Gonçalves, Marco Antonio Hungaro Duarte, Juliane Maria Guerreiro-Tanomaru, Mário Tanomaru-Filho","doi":"10.1007/s00784-025-06273-w","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To evaluate the performance in endodontic retreatment and pericervical dentin preservation using ProDesign Logic (PDL), Reciproc Blue (RB), and WaveOne Gold (WOG) NiTi systems in first (MB1) and second (MB2) mesiobuccal root canals of maxillary molars, using cone-beam computed tomography (CBCT) and micro-computed tomography (micro-CT).</p><p><strong>Materials and methods: </strong>MB1 and MB2 canals were prepared, filled, and randomized into four groups (n = 8). MB1 were retreated using PDL up to file 40/0.05 or RB R40 (40/0.06), while MB2 were retreated using PDL up to file 35/0.05 or WOG (35/0.06). Micro-CT scans were performed before and after retreatment to assess the remaining filling material, canal transportation, and canal centralization. Dentin removal and remaining dentin were measured at four levels below the furcation through CBCT scans analyzed with the e-Vol DX software, with micro-CT serving as the reference standard.</p><p><strong>Results: </strong>RB was more effective than PDL in removing MB1 filling material, while PDL outperformed WOG in the apical third of MB2 (p < 0.05). Overall, CBCT measurements for dentin removal were consistent with micro-CT in MB1 but occasionally underestimated in MB2 (p < 0.05). A significant reduction in MB2 danger zone dentin thickness below 0.5 mm was observed after retreatment (p < 0.05).</p><p><strong>Conclusions: </strong>RB was more effective in retreating MB1, while PDL was more efficient in the apical third of MB2. A substantial decrease in dentin thickness in the MB2 danger zone was noted after retreatment, regardless of the NiTi system or imaging modality used. Overall, CBCT scans provided consistent assessments of dentin.</p><p><strong>Clinical relevance: </strong>Selecting appropriate NiTi systems minimizes dentin removal in MB1 and MB2 danger zones, reducing the risk of perforation in the furcation area. CBCT reliably assesses dentin thickness, aiding clinical decisions and improving endodontic retreatment outcomes.</p>","PeriodicalId":10461,"journal":{"name":"Clinical Oral Investigations","volume":"29 4","pages":"194"},"PeriodicalIF":3.1000,"publicationDate":"2025-03-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical Oral Investigations","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00784-025-06273-w","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: To evaluate the performance in endodontic retreatment and pericervical dentin preservation using ProDesign Logic (PDL), Reciproc Blue (RB), and WaveOne Gold (WOG) NiTi systems in first (MB1) and second (MB2) mesiobuccal root canals of maxillary molars, using cone-beam computed tomography (CBCT) and micro-computed tomography (micro-CT).

Materials and methods: MB1 and MB2 canals were prepared, filled, and randomized into four groups (n = 8). MB1 were retreated using PDL up to file 40/0.05 or RB R40 (40/0.06), while MB2 were retreated using PDL up to file 35/0.05 or WOG (35/0.06). Micro-CT scans were performed before and after retreatment to assess the remaining filling material, canal transportation, and canal centralization. Dentin removal and remaining dentin were measured at four levels below the furcation through CBCT scans analyzed with the e-Vol DX software, with micro-CT serving as the reference standard.

Results: RB was more effective than PDL in removing MB1 filling material, while PDL outperformed WOG in the apical third of MB2 (p < 0.05). Overall, CBCT measurements for dentin removal were consistent with micro-CT in MB1 but occasionally underestimated in MB2 (p < 0.05). A significant reduction in MB2 danger zone dentin thickness below 0.5 mm was observed after retreatment (p < 0.05).

Conclusions: RB was more effective in retreating MB1, while PDL was more efficient in the apical third of MB2. A substantial decrease in dentin thickness in the MB2 danger zone was noted after retreatment, regardless of the NiTi system or imaging modality used. Overall, CBCT scans provided consistent assessments of dentin.

Clinical relevance: Selecting appropriate NiTi systems minimizes dentin removal in MB1 and MB2 danger zones, reducing the risk of perforation in the furcation area. CBCT reliably assesses dentin thickness, aiding clinical decisions and improving endodontic retreatment outcomes.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
三种NiTi系统在MB1和MB2根管根管再治疗中的有效性和安全性:micro-CT和CBCT联合分析
目的:应用锥形束计算机断层扫描(CBCT)和微计算机断层扫描(micro-CT),评价ProDesign Logic (PDL)、Reciproc Blue (RB)和WaveOne Gold (WOG) NiTi系统在上颌磨牙第一(MB1)和第二(MB2)中颊根管中根管再治疗和保存牙本质的效果。材料与方法:制备、填充MB1、MB2根管,随机分为4组(n = 8)。MB1采用PDL至文件40/0.05或RB R40(40/0.06)退退,MB2采用PDL至文件35/0.05或WOG(35/0.06)退退。再治疗前后进行Micro-CT扫描,评估剩余填充物、根管运输和根管集中情况。用e-Vol DX软件分析CBCT扫描结果,以micro-CT作为参考标准,测量牙本质去除和剩余牙本质在分叉以下四层的水平。结果:RB对MB1充填物的清除效果优于PDL,而PDL对MB2根尖三分之一的清除效果优于WOG (p结论:RB对MB1的清除效果更好,而PDL对MB2根尖三分之一的清除效果更好。再次治疗后,无论采用何种NiTi系统或成像方式,MB2危险区域的牙本质厚度都显著减少。总的来说,CBCT扫描提供了一致的牙本质评估。临床意义:选择合适的NiTi系统可以最大限度地减少MB1和MB2危险区域的牙本质去除,降低分叉区域穿孔的风险。CBCT可靠地评估牙本质厚度,帮助临床决策和改善牙髓再治疗的结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Clinical Oral Investigations
Clinical Oral Investigations 医学-牙科与口腔外科
CiteScore
6.30
自引率
5.90%
发文量
484
审稿时长
3 months
期刊介绍: The journal Clinical Oral Investigations is a multidisciplinary, international forum for publication of research from all fields of oral medicine. The journal publishes original scientific articles and invited reviews which provide up-to-date results of basic and clinical studies in oral and maxillofacial science and medicine. The aim is to clarify the relevance of new results to modern practice, for an international readership. Coverage includes maxillofacial and oral surgery, prosthetics and restorative dentistry, operative dentistry, endodontics, periodontology, orthodontics, dental materials science, clinical trials, epidemiology, pedodontics, oral implant, preventive dentistiry, oral pathology, oral basic sciences and more.
期刊最新文献
Evaluation of the effects of a gel containing green tea and hyaluronic acid on clinical and Microbiological outcomes following periodontal surgery. A randomized, controlled, double-blinded, noninferiority trial. Deep learning-based automated positioning system for maxillary skeletal expander: development and clinical validation. The impact of pulp disease on oral health-related quality of life in children aged 6 to 10 years. Clinical performance of a bulk-fill versus a nanofilled resin composite in non-carious cervical lesions with different extensions: a 6-years randomized, parallel, double-blind clinical trial. Nd: YAG laser-assisted treatment of subgingival microbiota composition in stage III-IV periodontitis: a randomized controlled study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1