Flow diverter is valid for aneurysms with incorporated branch vessels: Adding coil embolization and incorporated branch vessel diameter are predictors of treatment efficacy.
{"title":"Flow diverter is valid for aneurysms with incorporated branch vessels: Adding coil embolization and incorporated branch vessel diameter are predictors of treatment efficacy.","authors":"Kenichiro Suyama, Ichiro Nakahara, Shoji Matsumoto, Jun Morioka, Tetsuya Hashimoto, Junpei Koge, Jun Tanabe, Akiko Hasebe, Sadayoshi Watanabe, Takeya Suzuki, Yuichi Hirose","doi":"10.1016/j.jocn.2025.111192","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>This study aimed to determine the efficacy of flow diverters (FDs) for small/medium (≤10 mm) aneurysms and analyzed the factors that prevent aneurysm occlusion.</p><p><strong>Methods: </strong>This retrospective single-center study evaluated the angiographic and clinical data of consecutive patients between June 2020 and February 2023.</p><p><strong>Results: </strong>Overall, 121 small/medium aneurysms were observed in 106 patients treated with FDs. The median dome diameter was 6.1 (5.1-7.2) mm. Symptomatic thromboembolic complications were observed in four (3.7 %) patients, and none showed a major ischemic stroke. Intracranial hemorrhage was detected using postprocedural computed tomography in one (0.9 %) patient with asymptomatic subarachnoid hemorrhage. The rate of permanent neurological deficits was 1.8 %, and the mortality rate was 0 %. No delayed ischemic or hemorrhagic complications were observed during follow-up. Angiographic follow-up revealed complete and adequate occlusion (O'Kelly-Marotta grades C and D) rates of 77.5 % and 90.8 %, respectively. On multivariate analysis, incomplete occlusion was only associated with the presence of a branch vessel from the aneurysm dome (P < 0.01). In aneurysms with incorporated branch vessels, univariate analysis revealed that coil usage was a predictor of complete occlusion (P = 0.03). Moreover, even without using coils, effective occlusion was achieved when the branch vessel diameter was small (P = 0.03).</p><p><strong>Conclusions: </strong>FDs are an effective and safe treatment option for small/medium aneurysms. The presence of incorporated branch vessels can predict incomplete occlusion. Even in aneurysms with incorporated branch vessels, FD can obtain therapeutic effects by adding coil embolization or treating with only FD if the branch vessel diameter is small.</p>","PeriodicalId":15487,"journal":{"name":"Journal of Clinical Neuroscience","volume":"135 ","pages":"111192"},"PeriodicalIF":1.9000,"publicationDate":"2025-03-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Clinical Neuroscience","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.jocn.2025.111192","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Background: This study aimed to determine the efficacy of flow diverters (FDs) for small/medium (≤10 mm) aneurysms and analyzed the factors that prevent aneurysm occlusion.
Methods: This retrospective single-center study evaluated the angiographic and clinical data of consecutive patients between June 2020 and February 2023.
Results: Overall, 121 small/medium aneurysms were observed in 106 patients treated with FDs. The median dome diameter was 6.1 (5.1-7.2) mm. Symptomatic thromboembolic complications were observed in four (3.7 %) patients, and none showed a major ischemic stroke. Intracranial hemorrhage was detected using postprocedural computed tomography in one (0.9 %) patient with asymptomatic subarachnoid hemorrhage. The rate of permanent neurological deficits was 1.8 %, and the mortality rate was 0 %. No delayed ischemic or hemorrhagic complications were observed during follow-up. Angiographic follow-up revealed complete and adequate occlusion (O'Kelly-Marotta grades C and D) rates of 77.5 % and 90.8 %, respectively. On multivariate analysis, incomplete occlusion was only associated with the presence of a branch vessel from the aneurysm dome (P < 0.01). In aneurysms with incorporated branch vessels, univariate analysis revealed that coil usage was a predictor of complete occlusion (P = 0.03). Moreover, even without using coils, effective occlusion was achieved when the branch vessel diameter was small (P = 0.03).
Conclusions: FDs are an effective and safe treatment option for small/medium aneurysms. The presence of incorporated branch vessels can predict incomplete occlusion. Even in aneurysms with incorporated branch vessels, FD can obtain therapeutic effects by adding coil embolization or treating with only FD if the branch vessel diameter is small.
期刊介绍:
This International journal, Journal of Clinical Neuroscience, publishes articles on clinical neurosurgery and neurology and the related neurosciences such as neuro-pathology, neuro-radiology, neuro-ophthalmology and neuro-physiology.
The journal has a broad International perspective, and emphasises the advances occurring in Asia, the Pacific Rim region, Europe and North America. The Journal acts as a focus for publication of major clinical and laboratory research, as well as publishing solicited manuscripts on specific subjects from experts, case reports and other information of interest to clinicians working in the clinical neurosciences.