Differential Venous Drainage Mimicking Differential Oxygenation in Patients on Extracorporeal Life Support.

IF 2.3 3区 医学 Q2 ENGINEERING, BIOMEDICAL ASAIO Journal Pub Date : 2025-12-01 Epub Date: 2025-03-25 DOI:10.1097/MAT.0000000000002420
Johannes Heymer, Daniel Bent, Daniel Raepple
{"title":"Differential Venous Drainage Mimicking Differential Oxygenation in Patients on Extracorporeal Life Support.","authors":"Johannes Heymer, Daniel Bent, Daniel Raepple","doi":"10.1097/MAT.0000000000002420","DOIUrl":null,"url":null,"abstract":"<p><p>This report presents a case series that introduces differential venous drainage (DVD) as an underrated complication arising from the hemodynamic impact of the extracorporeal life support (ECLS) circuit on a patient's native circulation. In this series, we examine how DVD can be recognized and distinguished, particularly as its presentation may initially resemble the more extensively reported differential oxygenation (DO), a hemodynamic phenomenon observed in peripheral veno-arterial extracorporeal membrane oxygenation (V-A ECMO). Differential oxygenation, also known as differential hypoxemia or \"Harlequin Syndrome,\" manifests as an uneven distribution of oxygenated blood between the upper and lower body in patients on V-A ECMO. In contrast, DVD arises from DVD patterns within the circulation. Our analysis reveals cases where DVD produces symptoms similar to DO, highlighting its unique diagnostic and therapeutic challenges, its clinical significance, and its potential implications for patient outcomes. Additionally, we outline the various management strategies for both DO and DVD, underscoring the need for a deeper understanding of their respective impacts on clinical outcomes.</p>","PeriodicalId":8844,"journal":{"name":"ASAIO Journal","volume":" ","pages":"e225-e230"},"PeriodicalIF":2.3000,"publicationDate":"2025-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ASAIO Journal","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1097/MAT.0000000000002420","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/3/25 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

This report presents a case series that introduces differential venous drainage (DVD) as an underrated complication arising from the hemodynamic impact of the extracorporeal life support (ECLS) circuit on a patient's native circulation. In this series, we examine how DVD can be recognized and distinguished, particularly as its presentation may initially resemble the more extensively reported differential oxygenation (DO), a hemodynamic phenomenon observed in peripheral veno-arterial extracorporeal membrane oxygenation (V-A ECMO). Differential oxygenation, also known as differential hypoxemia or "Harlequin Syndrome," manifests as an uneven distribution of oxygenated blood between the upper and lower body in patients on V-A ECMO. In contrast, DVD arises from DVD patterns within the circulation. Our analysis reveals cases where DVD produces symptoms similar to DO, highlighting its unique diagnostic and therapeutic challenges, its clinical significance, and its potential implications for patient outcomes. Additionally, we outline the various management strategies for both DO and DVD, underscoring the need for a deeper understanding of their respective impacts on clinical outcomes.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
体外生命支持病人的不同静脉引流模拟不同氧合。
本报告介绍了一个病例系列,介绍了微分静脉引流(DVD)作为一种被低估的并发症,这种并发症是由体外生命支持(ECLS)回路对患者自然循环的血流动力学影响引起的。在本系列中,我们研究了如何识别和区分DVD,特别是当它的表现最初可能类似于更广泛报道的差氧合(DO),一种外周静脉-动脉体外膜氧合(V-A ECMO)中观察到的血流动力学现象。差异氧合,也称为差异低氧血症或“小丑综合征”,表现为V-A ECMO患者上半身和下半身含氧血分布不均匀。相反,DVD是由DVD的流通模式产生的。我们的分析揭示了DVD产生与DO相似症状的病例,强调了其独特的诊断和治疗挑战、临床意义以及对患者预后的潜在影响。此外,我们概述了DO和DVD的各种管理策略,强调需要更深入地了解它们各自对临床结果的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
ASAIO Journal
ASAIO Journal 医学-工程:生物医学
CiteScore
6.60
自引率
7.10%
发文量
651
审稿时长
4-8 weeks
期刊介绍: ASAIO Journal is in the forefront of artificial organ research and development. On the cutting edge of innovative technology, it features peer-reviewed articles of the highest quality that describe research, development, the most recent advances in the design of artificial organ devices and findings from initial testing. Bimonthly, the ASAIO Journal features state-of-the-art investigations, laboratory and clinical trials, and discussions and opinions from experts around the world. The official publication of the American Society for Artificial Internal Organs.
期刊最新文献
Introducer-Cannula Diameter Mismatch and Difficult Veno-Venous Extracorporeal Membrane Oxygenation Cannulation: A Case Report. Ethical Considerations in Extracorporeal Membrane Oxygenation Discontinuation Due to Resource Limitation. Response to Letter to the Editor (Ethical Considerations in Extracorporeal Membrane Oxygenation Discontinuation Due to Resource Limitation). Semi-Empirical Model to Predict Blood Flow in an Extracorporeal Respiratory Support Circuit Driven by Ventricular Assist Devices. Surgically Implanted Percutaneous Assist Device After Left Ventricular Assist Device Malfunction as a Bridge to Definitive Therapy.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1