The influence of different implantation depths on the hemodynamics in the treatment of stenosis in the starting segment of vertebral arteries.

IF 1.6 4区 医学 Q3 COMPUTER SCIENCE, INTERDISCIPLINARY APPLICATIONS Computer Methods in Biomechanics and Biomedical Engineering Pub Date : 2025-05-01 Epub Date: 2025-03-25 DOI:10.1080/10255842.2025.2480269
Yilin Zheng, Haiquan Feng, Qingsong Han, Yonggang Wang, Juan Su
{"title":"The influence of different implantation depths on the hemodynamics in the treatment of stenosis in the starting segment of vertebral arteries.","authors":"Yilin Zheng, Haiquan Feng, Qingsong Han, Yonggang Wang, Juan Su","doi":"10.1080/10255842.2025.2480269","DOIUrl":null,"url":null,"abstract":"<p><p>Stent implantation depth significantly influences the hemodynamics of the vertebral and subclavian arteries in treating vertebral artery stenosis. This study utilized computational fluid dynamics (CFD) to analyze key hemodynamic parameters in a vertebral artery model with a stent implanted at different depths. Results showed that excessive stent extension into the subclavian artery alters local blood flow, increasing the risk of thrombosis and plaque formation. An optimal implantation depth of 1-2 mm minimizes these risks. These findings provide a theoretical basis for optimizing stent placement, improving the efficacy and safety of interventional treatments for vertebral artery stenosis.</p>","PeriodicalId":50640,"journal":{"name":"Computer Methods in Biomechanics and Biomedical Engineering","volume":" ","pages":"841-854"},"PeriodicalIF":1.6000,"publicationDate":"2025-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Computer Methods in Biomechanics and Biomedical Engineering","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1080/10255842.2025.2480269","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/3/25 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"COMPUTER SCIENCE, INTERDISCIPLINARY APPLICATIONS","Score":null,"Total":0}
引用次数: 0

Abstract

Stent implantation depth significantly influences the hemodynamics of the vertebral and subclavian arteries in treating vertebral artery stenosis. This study utilized computational fluid dynamics (CFD) to analyze key hemodynamic parameters in a vertebral artery model with a stent implanted at different depths. Results showed that excessive stent extension into the subclavian artery alters local blood flow, increasing the risk of thrombosis and plaque formation. An optimal implantation depth of 1-2 mm minimizes these risks. These findings provide a theoretical basis for optimizing stent placement, improving the efficacy and safety of interventional treatments for vertebral artery stenosis.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
椎动脉起始段狭窄治疗中不同植入深度对血流动力学的影响。
在治疗椎动脉狭窄时,支架植入深度对椎动脉和锁骨下动脉血流动力学有显著影响。本研究利用计算流体动力学(CFD)分析了不同深度植入支架椎动脉模型的关键血流动力学参数。结果表明,支架过度延伸至锁骨下动脉改变了局部血流,增加了血栓形成和斑块形成的风险。最佳植入深度为1-2毫米,可将这些风险降到最低。这些发现为优化支架置入,提高椎动脉狭窄介入治疗的疗效和安全性提供了理论依据。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
4.10
自引率
6.20%
发文量
179
审稿时长
4-8 weeks
期刊介绍: The primary aims of Computer Methods in Biomechanics and Biomedical Engineering are to provide a means of communicating the advances being made in the areas of biomechanics and biomedical engineering and to stimulate interest in the continually emerging computer based technologies which are being applied in these multidisciplinary subjects. Computer Methods in Biomechanics and Biomedical Engineering will also provide a focus for the importance of integrating the disciplines of engineering with medical technology and clinical expertise. Such integration will have a major impact on health care in the future.
期刊最新文献
Exercise ECG classification based on HRV features induced by robust R-peak detection model. Bioinformatics analysis unveils hub genes in the pathogenesis of sevoflurane anesthesia-induced respiratory depression. Thorough biomechanical analysis of arterial response to EasyEndo-Lite staple rotation: a simulation study in abaqus. A fuzzy evaluation matrix method in early warning and classification of cardiovascular diseases. A simple deep transfer learning model with feature alignment block for motor imagery decoding.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1