OzMALDI: A Gas-Phase, In-Source Ozonolysis Reaction for Efficient Double-Bond Assignment in Mass Spectrometry Imaging with Matrix-Assisted Laser Desorption/Ionization

IF 6.7 1区 化学 Q1 CHEMISTRY, ANALYTICAL Analytical Chemistry Pub Date : 2025-03-31 DOI:10.1021/acs.analchem.5c00284
Josiah J. Rensner, Hyojin Kim, Kiyoul Park, Edgar B. Cahoon, Young Jin Lee
{"title":"OzMALDI: A Gas-Phase, In-Source Ozonolysis Reaction for Efficient Double-Bond Assignment in Mass Spectrometry Imaging with Matrix-Assisted Laser Desorption/Ionization","authors":"Josiah J. Rensner, Hyojin Kim, Kiyoul Park, Edgar B. Cahoon, Young Jin Lee","doi":"10.1021/acs.analchem.5c00284","DOIUrl":null,"url":null,"abstract":"Lipids make up an important class of biomolecules with diverse structures and varied chemical functions. This diversity is a major challenge in chemical analysis and limits our understanding of biological functions and regulation. A major way lipid isomers differ is by double-bond (db) position, and analyzing db-isomers is especially challenging for mass spectrometry imaging (MSI). Ozonolysis can be used to determine the db-position and has been paired with MSI before. However, previous techniques require increased analysis time to allow for gas-phase reactions within an ion trap or ion mobility cell or additional sample preparation time to allow for offline ozonation. Here, we introduce a new ozonolysis method inside the matrix-assisted laser desorption-ionization (MALDI) source, termed OzMALDI, that simultaneously produces ozonides from all unsaturated lipids. This allows us to determine db-positions without adding additional reaction time while maintaining the high mass resolution provided by Orbitrap MS. This new technique is especially effective at determining multiple db-positions in lipids containing polyunsaturated fatty acids, which is a limitation of many previous techniques. OzMALDI-MSI was applied to the analysis of rat brain and genetically engineered <i>Camelina</i> and soybean seed samples, demonstrating the utility of this method and uncovering novel biological information.","PeriodicalId":27,"journal":{"name":"Analytical Chemistry","volume":"34 1","pages":""},"PeriodicalIF":6.7000,"publicationDate":"2025-03-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical Chemistry","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1021/acs.analchem.5c00284","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Lipids make up an important class of biomolecules with diverse structures and varied chemical functions. This diversity is a major challenge in chemical analysis and limits our understanding of biological functions and regulation. A major way lipid isomers differ is by double-bond (db) position, and analyzing db-isomers is especially challenging for mass spectrometry imaging (MSI). Ozonolysis can be used to determine the db-position and has been paired with MSI before. However, previous techniques require increased analysis time to allow for gas-phase reactions within an ion trap or ion mobility cell or additional sample preparation time to allow for offline ozonation. Here, we introduce a new ozonolysis method inside the matrix-assisted laser desorption-ionization (MALDI) source, termed OzMALDI, that simultaneously produces ozonides from all unsaturated lipids. This allows us to determine db-positions without adding additional reaction time while maintaining the high mass resolution provided by Orbitrap MS. This new technique is especially effective at determining multiple db-positions in lipids containing polyunsaturated fatty acids, which is a limitation of many previous techniques. OzMALDI-MSI was applied to the analysis of rat brain and genetically engineered Camelina and soybean seed samples, demonstrating the utility of this method and uncovering novel biological information.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
OzMALDI:在基质辅助激光解吸/电离质谱成像中用于有效双键分配的气相,源内臭氧分解反应
脂类是一类重要的生物分子,具有多种结构和多种化学功能。这种多样性是化学分析的主要挑战,限制了我们对生物功能和调控的理解。脂质异构体的主要区别在于双键(db)的位置,而分析双键异构体对于质谱成像(MSI)来说尤其具有挑战性。臭氧分解可用于确定db位置,并已与MSI配对。然而,以前的技术需要增加分析时间,以允许离子阱或离子流动池内的气相反应,或额外的样品制备时间,以允许离线臭氧化。在这里,我们介绍了一种新的臭氧分解方法,在基质辅助激光解吸-电离(MALDI)源内,称为OzMALDI,同时从所有不饱和脂质中产生臭氧化物。这使我们能够在不增加额外反应时间的情况下确定db位置,同时保持Orbitrap ms提供的高质量分辨率。这项新技术在确定含有多不饱和脂肪酸的脂质中的多个db位置时特别有效,这是许多以前技术的局限性。将OzMALDI-MSI应用于大鼠脑和转基因亚麻荠和大豆种子样本的分析,证明了该方法的实用性,并揭示了新的生物信息。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Analytical Chemistry
Analytical Chemistry 化学-分析化学
CiteScore
12.10
自引率
12.20%
发文量
1949
审稿时长
1.4 months
期刊介绍: Analytical Chemistry, a peer-reviewed research journal, focuses on disseminating new and original knowledge across all branches of analytical chemistry. Fundamental articles may explore general principles of chemical measurement science and need not directly address existing or potential analytical methodology. They can be entirely theoretical or report experimental results. Contributions may cover various phases of analytical operations, including sampling, bioanalysis, electrochemistry, mass spectrometry, microscale and nanoscale systems, environmental analysis, separations, spectroscopy, chemical reactions and selectivity, instrumentation, imaging, surface analysis, and data processing. Papers discussing known analytical methods should present a significant, original application of the method, a notable improvement, or results on an important analyte.
期刊最新文献
Potentiostatic Current-to-Electrochemiluminescence Conversion for Real Time Detection of Low-Intensity Faradaic Events: Application to Nano-Impact Electrochemistry. Encapsulation of mRNA in Therapeutics Like Lipid Nanoparticles Probed by Deep-UV Resonance Raman Spectroscopy mtDNApipe: A Pioneering Pipeline for High-Sensitivity Detection of Low-Frequency Mitochondrial DNA Mutations Alternating Current-Driven Silver Needle-Based Electrochemiluminescence Biosensor for Rapid and Low-Damage Diagnosis of Cerebral Hemorrhage with Edema Mass-Invariant Natural Log-Transformed Mass Spectra Enable Internal Calibration and De Novo Sequencing of Intact Proteins
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1